{"id":1056,"date":"2016-06-06T10:11:29","date_gmt":"2016-06-06T14:11:29","guid":{"rendered":"https:\/\/www.mroelectric.com\/blog\/?p=1056"},"modified":"2020-03-05T11:18:26","modified_gmt":"2020-03-05T16:18:26","slug":"uni2403-configuration-setup","status":"publish","type":"post","link":"https:\/\/www.mroelectric.com\/blog\/uni2403-configuration-setup\/","title":{"rendered":"UNI2403 Configuration and Setup"},"content":{"rendered":"<p>The <a href=\"https:\/\/www.mroelectric.com\/product\/UNI2403\">UNI2403 and UNI2403-r configuration<\/a> process is a relatively simple setup process that should be able to get you back up and running with minimal downtime.<\/p>\n<h6>With some simple UNI2403 11kw configuration the drive can be used as an AC Regenerative Unit, also known as a Regen Drive. In the case of a drive operating in Regen mode, the IGBT bridge is used as a sinusoidal rectifier, which converts the AC supply to a controlled DC voltage. This DC voltage can then be used to supply one or more Unidrives which control motors, commonly known as motoring drives.<\/h6>\n<p>A regen drive produces PWM output voltage which has a sinusoidal fundamental at an amplitude and phase which are almost the same as those of the AC supply voltage. The difference between the drive PWM line voltage and the supply voltage occurs across the Regen drive&#8217;s inductors.<\/p>\n<p>There are a number of possible options available when designing a Unidrive Regen system depending on the user requirements and the nature of the AC supply. Non standard systems can be created where favourable supply conditions exist, allowing cost and space savings to be achieved by reducing the number of components.<\/p>\n<p><a href=\"https:\/\/www.mroelectric.com\/control-techniques\/unidrive\/1\">A Unidrive<\/a> can be used as a sinusoidal input current power unit to supply one or more Unidrives via their DC buses. When this mode is selected as the drive type, menu 15 appears. This menu is used to set up the Unidrive. At the same time, menu 0 defaults to showing Pr 15.01 to Pr 15.13 as Pr0.11 to Pr 0.28.<\/p>\n<p>You can check out our previous blog post on the UNI2403 manual and UNI2403-r manual <a href=\"https:\/\/www.mroelectric.com\/blog\/uni2403-beyond-user-manual\/\">here <\/a>with additional setup info. To get a UNI2403 price quote or for ordering info you can call 1-800-691-8511 or email <a href=\"mailto:sales@mroelectric.com\">sales@mroelectric.com<\/a>.<\/p>\n<p><a href=\"mailto:sales@mroelectric.com?subject=Request%20for%20Quote&amp;body=Part%20%23%20%28s%29%3A%20%0A%0AQuantity%3A%20%0A%0AManufacturer%3A%20%0A%0ANew%20%2F%20Reman%3A%20%0A%0A%0ADescription%20%2F%20Comments%20%2F%20Urgency%3A%20%0A%0ACompany%20Name%3A%20%0A%0AContact%20Name%3A%20\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1171\" src=\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2016\/07\/quote-btn.png\" alt=\"\" width=\"292\" height=\"62\"><\/a><\/p>\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter\"><img loading=\"lazy\" decoding=\"async\" width=\"342\" height=\"375\" src=\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/UNI2403.jpg\" alt=\"\" class=\"wp-image-3941\" srcset=\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/UNI2403.jpg 342w, https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/UNI2403-274x300.jpg 274w\" sizes=\"auto, (max-width: 342px) 100vw, 342px\" \/><\/figure><\/div>\n","protected":false},"excerpt":{"rendered":"<p>The UNI2403 and UNI2403-r configuration process is a relatively simple setup process that should be able to get you back up and running with minimal downtime. With some simple UNI2403 11kw configuration the drive can be used as an AC Regenerative Unit, also known as a Regen Drive. In the case of a drive operating [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"","_lmt_disable":"","_exactmetrics_skip_tracking":false,"_exactmetrics_sitenote_active":false,"_exactmetrics_sitenote_note":"","_exactmetrics_sitenote_category":0,"ngg_post_thumbnail":0,"footnotes":""},"categories":[97,12],"tags":[85,178,15],"class_list":["post-1056","post","type-post","status-publish","format-standard","hentry","category-control-techniques","category-troubleshooting-and-repair","tag-motors-and-drives","tag-setup-and-configuration","tag-unidrive"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v25.3.1 (Yoast SEO v25.3.1) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Control Techniques UNI2403 Configuration and Setup<\/title>\n<meta name=\"description\" content=\"The UNI2403 configuration process is a relatively simple setup process that should be able to get you back up and running with minimal downtime.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.mroelectric.com\/blog\/uni2403-configuration-setup\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"UNI2403 Configuration and Setup\" \/>\n<meta property=\"og:description\" content=\"The UNI2403 configuration process is a relatively simple setup process that should be able to get you back up and running with minimal downtime.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.mroelectric.com\/blog\/uni2403-configuration-setup\/\" \/>\n<meta property=\"og:site_name\" content=\"MRO Electric Blog\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/mroelectric\/\" \/>\n<meta property=\"article:published_time\" content=\"2016-06-06T14:11:29+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-03-05T16:18:26+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2016\/07\/quote-btn.png\" \/>\n<meta name=\"author\" content=\"Joe Kaminski\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@mroelectric\" \/>\n<meta name=\"twitter:site\" content=\"@mroelectric\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Joe Kaminski\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/uni2403-configuration-setup\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/uni2403-configuration-setup\/\"},\"author\":{\"name\":\"Joe Kaminski\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/b993515a2417163a23dfe88597c8d13a\"},\"headline\":\"UNI2403 Configuration and Setup\",\"datePublished\":\"2016-06-06T14:11:29+00:00\",\"dateModified\":\"2020-03-05T16:18:26+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/uni2403-configuration-setup\/\"},\"wordCount\":301,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#organization\"},\"image\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/uni2403-configuration-setup\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2016\/07\/quote-btn.png\",\"keywords\":[\"Motors &amp; Drives\",\"Setup &amp; Configuration\",\"Unidrive\"],\"articleSection\":[\"Control Techniques\",\"Troubleshooting &amp; Repair\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/www.mroelectric.com\/blog\/uni2403-configuration-setup\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/uni2403-configuration-setup\/\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/uni2403-configuration-setup\/\",\"name\":\"Control Techniques UNI2403 Configuration and Setup\",\"isPartOf\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/uni2403-configuration-setup\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/uni2403-configuration-setup\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2016\/07\/quote-btn.png\",\"datePublished\":\"2016-06-06T14:11:29+00:00\",\"dateModified\":\"2020-03-05T16:18:26+00:00\",\"description\":\"The UNI2403 configuration process is a relatively simple setup process that should be able to get you back up and running with minimal downtime.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/uni2403-configuration-setup\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.mroelectric.com\/blog\/uni2403-configuration-setup\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/uni2403-configuration-setup\/#primaryimage\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2016\/07\/quote-btn.png\",\"contentUrl\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2016\/07\/quote-btn.png\",\"width\":292,\"height\":62,\"caption\":\"Instant Quote\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/uni2403-configuration-setup\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.mroelectric.com\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"UNI2403 Configuration and Setup\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#website\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/\",\"name\":\"MRO Electric Blog\",\"description\":\"Applications of PLCs, CNCs, and more!\",\"publisher\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.mroelectric.com\/blog\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#organization\",\"name\":\"MRO Electric and Supply\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro-logo-new_large2_blue-1.png\",\"contentUrl\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro-logo-new_large2_blue-1.png\",\"width\":430,\"height\":222,\"caption\":\"MRO Electric and Supply\"},\"image\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/mroelectric\/\",\"https:\/\/x.com\/mroelectric\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/b993515a2417163a23dfe88597c8d13a\",\"name\":\"Joe Kaminski\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/fb7c0d641ed541ad912b27609e8079304fc356be7b5b53578b32ad3fa973f506?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/fb7c0d641ed541ad912b27609e8079304fc356be7b5b53578b32ad3fa973f506?s=96&d=mm&r=g\",\"caption\":\"Joe Kaminski\"},\"description\":\"Joe Kaminski is an industrial automation specialist at MRO Electric. He has a background in industrial engineering and supply chain management. Joe has worked in the automation industry for over 10 years providing support to some of the largest companies in the world. For more info, visit www.mroelectric.com.\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/author\/jadmin\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Control Techniques UNI2403 Configuration and Setup","description":"The UNI2403 configuration process is a relatively simple setup process that should be able to get you back up and running with minimal downtime.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.mroelectric.com\/blog\/uni2403-configuration-setup\/","og_locale":"en_US","og_type":"article","og_title":"UNI2403 Configuration and Setup","og_description":"The UNI2403 configuration process is a relatively simple setup process that should be able to get you back up and running with minimal downtime.","og_url":"https:\/\/www.mroelectric.com\/blog\/uni2403-configuration-setup\/","og_site_name":"MRO Electric Blog","article_publisher":"https:\/\/www.facebook.com\/mroelectric\/","article_published_time":"2016-06-06T14:11:29+00:00","article_modified_time":"2020-03-05T16:18:26+00:00","og_image":[{"url":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2016\/07\/quote-btn.png","type":"","width":"","height":""}],"author":"Joe Kaminski","twitter_card":"summary_large_image","twitter_creator":"@mroelectric","twitter_site":"@mroelectric","twitter_misc":{"Written by":"Joe Kaminski","Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.mroelectric.com\/blog\/uni2403-configuration-setup\/#article","isPartOf":{"@id":"https:\/\/www.mroelectric.com\/blog\/uni2403-configuration-setup\/"},"author":{"name":"Joe Kaminski","@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/b993515a2417163a23dfe88597c8d13a"},"headline":"UNI2403 Configuration and Setup","datePublished":"2016-06-06T14:11:29+00:00","dateModified":"2020-03-05T16:18:26+00:00","mainEntityOfPage":{"@id":"https:\/\/www.mroelectric.com\/blog\/uni2403-configuration-setup\/"},"wordCount":301,"commentCount":0,"publisher":{"@id":"https:\/\/www.mroelectric.com\/blog\/#organization"},"image":{"@id":"https:\/\/www.mroelectric.com\/blog\/uni2403-configuration-setup\/#primaryimage"},"thumbnailUrl":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2016\/07\/quote-btn.png","keywords":["Motors &amp; Drives","Setup &amp; Configuration","Unidrive"],"articleSection":["Control Techniques","Troubleshooting &amp; Repair"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.mroelectric.com\/blog\/uni2403-configuration-setup\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.mroelectric.com\/blog\/uni2403-configuration-setup\/","url":"https:\/\/www.mroelectric.com\/blog\/uni2403-configuration-setup\/","name":"Control Techniques UNI2403 Configuration and Setup","isPartOf":{"@id":"https:\/\/www.mroelectric.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.mroelectric.com\/blog\/uni2403-configuration-setup\/#primaryimage"},"image":{"@id":"https:\/\/www.mroelectric.com\/blog\/uni2403-configuration-setup\/#primaryimage"},"thumbnailUrl":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2016\/07\/quote-btn.png","datePublished":"2016-06-06T14:11:29+00:00","dateModified":"2020-03-05T16:18:26+00:00","description":"The UNI2403 configuration process is a relatively simple setup process that should be able to get you back up and running with minimal downtime.","breadcrumb":{"@id":"https:\/\/www.mroelectric.com\/blog\/uni2403-configuration-setup\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.mroelectric.com\/blog\/uni2403-configuration-setup\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mroelectric.com\/blog\/uni2403-configuration-setup\/#primaryimage","url":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2016\/07\/quote-btn.png","contentUrl":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2016\/07\/quote-btn.png","width":292,"height":62,"caption":"Instant Quote"},{"@type":"BreadcrumbList","@id":"https:\/\/www.mroelectric.com\/blog\/uni2403-configuration-setup\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.mroelectric.com\/blog\/"},{"@type":"ListItem","position":2,"name":"UNI2403 Configuration and Setup"}]},{"@type":"WebSite","@id":"https:\/\/www.mroelectric.com\/blog\/#website","url":"https:\/\/www.mroelectric.com\/blog\/","name":"MRO Electric Blog","description":"Applications of PLCs, CNCs, and more!","publisher":{"@id":"https:\/\/www.mroelectric.com\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.mroelectric.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.mroelectric.com\/blog\/#organization","name":"MRO Electric and Supply","url":"https:\/\/www.mroelectric.com\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro-logo-new_large2_blue-1.png","contentUrl":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro-logo-new_large2_blue-1.png","width":430,"height":222,"caption":"MRO Electric and Supply"},"image":{"@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/mroelectric\/","https:\/\/x.com\/mroelectric"]},{"@type":"Person","@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/b993515a2417163a23dfe88597c8d13a","name":"Joe Kaminski","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/fb7c0d641ed541ad912b27609e8079304fc356be7b5b53578b32ad3fa973f506?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/fb7c0d641ed541ad912b27609e8079304fc356be7b5b53578b32ad3fa973f506?s=96&d=mm&r=g","caption":"Joe Kaminski"},"description":"Joe Kaminski is an industrial automation specialist at MRO Electric. He has a background in industrial engineering and supply chain management. Joe has worked in the automation industry for over 10 years providing support to some of the largest companies in the world. For more info, visit www.mroelectric.com.","url":"https:\/\/www.mroelectric.com\/blog\/author\/jadmin\/"}]}},"modified_by":"Brian Hughes","_links":{"self":[{"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/posts\/1056","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/comments?post=1056"}],"version-history":[{"count":10,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/posts\/1056\/revisions"}],"predecessor-version":[{"id":4513,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/posts\/1056\/revisions\/4513"}],"wp:attachment":[{"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/media?parent=1056"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/categories?post=1056"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/tags?post=1056"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}