{"id":1224,"date":"2016-07-20T09:56:36","date_gmt":"2016-07-20T13:56:36","guid":{"rendered":"https:\/\/www.mroelectric.com\/blog\/?p=1224"},"modified":"2020-05-14T10:11:46","modified_gmt":"2020-05-14T14:11:46","slug":"140cpu43412a-firmware-part-ii","status":"publish","type":"post","link":"https:\/\/www.mroelectric.com\/blog\/140cpu43412a-firmware-part-ii\/","title":{"rendered":"140CPU43412A Firmware Part II"},"content":{"rendered":"<p>Phase 1 of firmware restoration is described in our previous blog post on the <a href=\"https:\/\/www.mroelectric.com\/blog\/140cpu43412a-firmware\/\">140CPU43412A firmware<\/a>.<\/p>\n<h6>140CPU43412A Firmware Part II<\/h6>\n<p>Restoring a <a href=\"https:\/\/www.mroelectric.com\/product\/140CPU43412U\">140CPU43412U (Unity)<\/a> to <a href=\"https:\/\/www.mroelectric.com\/product\/140CPU43412A\">140CPU43412A (Concept)<\/a>:<\/p>\n<p><em><strong><span style=\"text-decoration: underline;\">Phase 2<\/span><\/strong><\/em><\/p>\n<p>During the download:<\/p>\n<p>\u2022 Do not power OFF the PLC<\/p>\n<p>\u2022 Do not power OFF the PC<\/p>\n<p>\u2022 Do not disconnect the cable<\/p>\n<p>\u2022 Do not shut down OS loader<\/p>\n<p>Any loss of communication during the update procedure can cause severe damage to the <a href=\"https:\/\/www.mroelectric.com\/category\/cpu\/1\" target=\"_blank\" rel=\"noopener noreferrer\">CPU<\/a> or NOE module. Failure to follow these instructions can result in injury or equipment damage.<\/p>\n<p><strong>Reset the PLC<\/strong><\/p>\n<p>Once the download of the intermediate binary file has completed, the <a href=\"https:\/\/www.mroelectric.com\/category\/plc\/1\" target=\"_blank\" rel=\"noopener noreferrer\">PLC<\/a> has to be initialized. This task can be performed by one of the two following actions: \u0001 Reset the PLC by pushing on the Restart button located on the CPU (for more information, refer to the PLC technical documentation). \u0001 Power OFF then ON the PLC. Once the PLC has restarted, go to Phase 3: download the final Concept OS.<\/p>\n<p><em><strong><span style=\"text-decoration: underline;\">Phase 3<\/span><\/strong><\/em><\/p>\n<p><strong>Presentation<\/strong><\/p>\n<p>The final binary file \u201cq5rv135E.bin \u201d (140CPU34312 in our example) has to be downloaded. For that, follow the same procedure as the one described in the Phase 1.<\/p>\n<p><strong>Checking Version (optional)<\/strong><\/p>\n<p>If needed, you can check the new CPU version. For that \u0001 Open the OS loader tool. \u0001 Select the communication protocol. \u0001 Click on &#8220;Connect.&#8221; Then Click on &#8220;Properties.&#8221;<\/p>\n<h6>For ordering info or for a 140CPU43412A price quote you can call 1-800-691-8511 or email <a href=\"mailto:sales@mroelectric.com\">sales@mroelectric.com<\/a>.<\/h6>\n<p><a href=\"mailto:sales@mroelectric.com?subject=Request%20for%20Quote&amp;body=Part%20%23%20%28s%29%3A%20%0A%0AQuantity%3A%20%0A%0AManufacturer%3A%20%0A%0ANew%20%2F%20Reman%3A%20%0A%0A%0ADescription%20%2F%20Comments%20%2F%20Urgency%3A%20%0A%0ACompany%20Name%3A%20%0A%0AContact%20Name%3A%20\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1171\" src=\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2016\/07\/quote-btn.png\" alt=\"\" width=\"292\" height=\"62\" \/><\/a><\/p>\n<figure id=\"attachment_1077\" class=\"thumbnail wp-caption alignnone\" style=\"width: 343px\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-1077\" src=\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2016\/06\/140cpu43412a.jpg\" alt=\"140CPU43412A \" width=\"333\" height=\"700\" srcset=\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2016\/06\/140cpu43412a.jpg 333w, https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2016\/06\/140cpu43412a-143x300.jpg 143w\" sizes=\"auto, (max-width: 333px) 100vw, 333px\" \/><figcaption class=\"caption wp-caption-text\">140CPU43412A FIrmware<\/figcaption><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Phase 1 of firmware restoration is described in our previous blog post on the 140CPU43412A firmware. 140CPU43412A Firmware Part II Restoring a 140CPU43412U (Unity) to 140CPU43412A (Concept): Phase 2 During the download: \u2022 Do not power OFF the PLC \u2022 Do not power OFF the PC \u2022 Do not disconnect the cable \u2022 Do not [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"","_lmt_disable":"","_exactmetrics_skip_tracking":false,"_exactmetrics_sitenote_active":false,"_exactmetrics_sitenote_note":"","_exactmetrics_sitenote_category":0,"ngg_post_thumbnail":0,"footnotes":""},"categories":[10,96,12],"tags":[67,84],"class_list":["post-1224","post","type-post","status-publish","format-standard","hentry","category-plc-application","category-schneider-electric","category-troubleshooting-and-repair","tag-alarm-and-fault-codes","tag-cpu"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v25.3.1 (Yoast SEO v25.3.1) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Modicon Quantum 140CPU43412A Firmware Part II<\/title>\n<meta name=\"description\" content=\"140CPU43412A Firmware Description and Restoration. This post discusses the restoration of a 140CPU43412U (Unity) to 140CPU43412A (Concept):\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.mroelectric.com\/blog\/140cpu43412a-firmware-part-ii\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"140CPU43412A Firmware Part II\" \/>\n<meta property=\"og:description\" content=\"140CPU43412A Firmware Description and Restoration. This post discusses the restoration of a 140CPU43412U (Unity) to 140CPU43412A (Concept):\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.mroelectric.com\/blog\/140cpu43412a-firmware-part-ii\/\" \/>\n<meta property=\"og:site_name\" content=\"MRO Electric Blog\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/mroelectric\/\" \/>\n<meta property=\"article:published_time\" content=\"2016-07-20T13:56:36+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-05-14T14:11:46+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2016\/07\/quote-btn.png\" \/>\n<meta name=\"author\" content=\"Joe Kaminski\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@mroelectric\" \/>\n<meta name=\"twitter:site\" content=\"@mroelectric\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Joe Kaminski\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/140cpu43412a-firmware-part-ii\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/140cpu43412a-firmware-part-ii\/\"},\"author\":{\"name\":\"Joe Kaminski\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/b993515a2417163a23dfe88597c8d13a\"},\"headline\":\"140CPU43412A Firmware Part II\",\"datePublished\":\"2016-07-20T13:56:36+00:00\",\"dateModified\":\"2020-05-14T14:11:46+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/140cpu43412a-firmware-part-ii\/\"},\"wordCount\":256,\"commentCount\":1,\"publisher\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#organization\"},\"image\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/140cpu43412a-firmware-part-ii\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2016\/07\/quote-btn.png\",\"keywords\":[\"Alarms &amp; Faults\",\"CPU\"],\"articleSection\":[\"PLC Applications\",\"Schneider Electric\",\"Troubleshooting &amp; Repair\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/www.mroelectric.com\/blog\/140cpu43412a-firmware-part-ii\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/140cpu43412a-firmware-part-ii\/\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/140cpu43412a-firmware-part-ii\/\",\"name\":\"Modicon Quantum 140CPU43412A Firmware Part II\",\"isPartOf\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/140cpu43412a-firmware-part-ii\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/140cpu43412a-firmware-part-ii\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2016\/07\/quote-btn.png\",\"datePublished\":\"2016-07-20T13:56:36+00:00\",\"dateModified\":\"2020-05-14T14:11:46+00:00\",\"description\":\"140CPU43412A Firmware Description and Restoration. This post discusses the restoration of a 140CPU43412U (Unity) to 140CPU43412A (Concept):\",\"breadcrumb\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/140cpu43412a-firmware-part-ii\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.mroelectric.com\/blog\/140cpu43412a-firmware-part-ii\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/140cpu43412a-firmware-part-ii\/#primaryimage\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2016\/07\/quote-btn.png\",\"contentUrl\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2016\/07\/quote-btn.png\",\"width\":292,\"height\":62,\"caption\":\"Instant Quote\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/140cpu43412a-firmware-part-ii\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.mroelectric.com\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"140CPU43412A Firmware Part II\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#website\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/\",\"name\":\"MRO Electric Blog\",\"description\":\"Applications of PLCs, CNCs, and more!\",\"publisher\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.mroelectric.com\/blog\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#organization\",\"name\":\"MRO Electric and Supply\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro-logo-new_large2_blue-1.png\",\"contentUrl\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro-logo-new_large2_blue-1.png\",\"width\":430,\"height\":222,\"caption\":\"MRO Electric and Supply\"},\"image\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/mroelectric\/\",\"https:\/\/x.com\/mroelectric\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/b993515a2417163a23dfe88597c8d13a\",\"name\":\"Joe Kaminski\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/fb7c0d641ed541ad912b27609e8079304fc356be7b5b53578b32ad3fa973f506?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/fb7c0d641ed541ad912b27609e8079304fc356be7b5b53578b32ad3fa973f506?s=96&d=mm&r=g\",\"caption\":\"Joe Kaminski\"},\"description\":\"Joe Kaminski is an industrial automation specialist at MRO Electric. He has a background in industrial engineering and supply chain management. Joe has worked in the automation industry for over 10 years providing support to some of the largest companies in the world. For more info, visit www.mroelectric.com.\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/author\/jadmin\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Modicon Quantum 140CPU43412A Firmware Part II","description":"140CPU43412A Firmware Description and Restoration. This post discusses the restoration of a 140CPU43412U (Unity) to 140CPU43412A (Concept):","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.mroelectric.com\/blog\/140cpu43412a-firmware-part-ii\/","og_locale":"en_US","og_type":"article","og_title":"140CPU43412A Firmware Part II","og_description":"140CPU43412A Firmware Description and Restoration. This post discusses the restoration of a 140CPU43412U (Unity) to 140CPU43412A (Concept):","og_url":"https:\/\/www.mroelectric.com\/blog\/140cpu43412a-firmware-part-ii\/","og_site_name":"MRO Electric Blog","article_publisher":"https:\/\/www.facebook.com\/mroelectric\/","article_published_time":"2016-07-20T13:56:36+00:00","article_modified_time":"2020-05-14T14:11:46+00:00","og_image":[{"url":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2016\/07\/quote-btn.png","type":"","width":"","height":""}],"author":"Joe Kaminski","twitter_card":"summary_large_image","twitter_creator":"@mroelectric","twitter_site":"@mroelectric","twitter_misc":{"Written by":"Joe Kaminski","Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.mroelectric.com\/blog\/140cpu43412a-firmware-part-ii\/#article","isPartOf":{"@id":"https:\/\/www.mroelectric.com\/blog\/140cpu43412a-firmware-part-ii\/"},"author":{"name":"Joe Kaminski","@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/b993515a2417163a23dfe88597c8d13a"},"headline":"140CPU43412A Firmware Part II","datePublished":"2016-07-20T13:56:36+00:00","dateModified":"2020-05-14T14:11:46+00:00","mainEntityOfPage":{"@id":"https:\/\/www.mroelectric.com\/blog\/140cpu43412a-firmware-part-ii\/"},"wordCount":256,"commentCount":1,"publisher":{"@id":"https:\/\/www.mroelectric.com\/blog\/#organization"},"image":{"@id":"https:\/\/www.mroelectric.com\/blog\/140cpu43412a-firmware-part-ii\/#primaryimage"},"thumbnailUrl":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2016\/07\/quote-btn.png","keywords":["Alarms &amp; Faults","CPU"],"articleSection":["PLC Applications","Schneider Electric","Troubleshooting &amp; Repair"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.mroelectric.com\/blog\/140cpu43412a-firmware-part-ii\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.mroelectric.com\/blog\/140cpu43412a-firmware-part-ii\/","url":"https:\/\/www.mroelectric.com\/blog\/140cpu43412a-firmware-part-ii\/","name":"Modicon Quantum 140CPU43412A Firmware Part II","isPartOf":{"@id":"https:\/\/www.mroelectric.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.mroelectric.com\/blog\/140cpu43412a-firmware-part-ii\/#primaryimage"},"image":{"@id":"https:\/\/www.mroelectric.com\/blog\/140cpu43412a-firmware-part-ii\/#primaryimage"},"thumbnailUrl":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2016\/07\/quote-btn.png","datePublished":"2016-07-20T13:56:36+00:00","dateModified":"2020-05-14T14:11:46+00:00","description":"140CPU43412A Firmware Description and Restoration. This post discusses the restoration of a 140CPU43412U (Unity) to 140CPU43412A (Concept):","breadcrumb":{"@id":"https:\/\/www.mroelectric.com\/blog\/140cpu43412a-firmware-part-ii\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.mroelectric.com\/blog\/140cpu43412a-firmware-part-ii\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mroelectric.com\/blog\/140cpu43412a-firmware-part-ii\/#primaryimage","url":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2016\/07\/quote-btn.png","contentUrl":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2016\/07\/quote-btn.png","width":292,"height":62,"caption":"Instant Quote"},{"@type":"BreadcrumbList","@id":"https:\/\/www.mroelectric.com\/blog\/140cpu43412a-firmware-part-ii\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.mroelectric.com\/blog\/"},{"@type":"ListItem","position":2,"name":"140CPU43412A Firmware Part II"}]},{"@type":"WebSite","@id":"https:\/\/www.mroelectric.com\/blog\/#website","url":"https:\/\/www.mroelectric.com\/blog\/","name":"MRO Electric Blog","description":"Applications of PLCs, CNCs, and more!","publisher":{"@id":"https:\/\/www.mroelectric.com\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.mroelectric.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.mroelectric.com\/blog\/#organization","name":"MRO Electric and Supply","url":"https:\/\/www.mroelectric.com\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro-logo-new_large2_blue-1.png","contentUrl":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro-logo-new_large2_blue-1.png","width":430,"height":222,"caption":"MRO Electric and Supply"},"image":{"@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/mroelectric\/","https:\/\/x.com\/mroelectric"]},{"@type":"Person","@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/b993515a2417163a23dfe88597c8d13a","name":"Joe Kaminski","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/fb7c0d641ed541ad912b27609e8079304fc356be7b5b53578b32ad3fa973f506?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/fb7c0d641ed541ad912b27609e8079304fc356be7b5b53578b32ad3fa973f506?s=96&d=mm&r=g","caption":"Joe Kaminski"},"description":"Joe Kaminski is an industrial automation specialist at MRO Electric. He has a background in industrial engineering and supply chain management. Joe has worked in the automation industry for over 10 years providing support to some of the largest companies in the world. For more info, visit www.mroelectric.com.","url":"https:\/\/www.mroelectric.com\/blog\/author\/jadmin\/"}]}},"modified_by":"David Link","_links":{"self":[{"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/posts\/1224","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/comments?post=1224"}],"version-history":[{"count":5,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/posts\/1224\/revisions"}],"predecessor-version":[{"id":4621,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/posts\/1224\/revisions\/4621"}],"wp:attachment":[{"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/media?parent=1224"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/categories?post=1224"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/tags?post=1224"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}