{"id":1589,"date":"2017-03-31T10:40:35","date_gmt":"2017-03-31T14:40:35","guid":{"rendered":"https:\/\/www.mroelectric.com\/blog\/?p=1589"},"modified":"2020-03-05T11:02:45","modified_gmt":"2020-03-05T16:02:45","slug":"magelis-faq-ii","status":"publish","type":"post","link":"https:\/\/www.mroelectric.com\/blog\/magelis-faq-ii\/","title":{"rendered":"Schneider Electric Magelis HMIs &#8211; Frequently Asked Questions Part II"},"content":{"rendered":"<h5>MRO Electric carries new and refurbished <a href=\"https:\/\/www.mroelectric.com\/schneider-electric\/modicon-magelis\/1\">Magelis HMIs<\/a>. To request a quote, please call 800-691-8511 or email <a href=\"mailto:sales@mroelectric.com\">sales@mroelectric.com<\/a>.<\/h5>\n<figure id=\"attachment_1536\" class=\"thumbnail wp-caption alignnone\" style=\"width: 614px\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-1536 size-large\" src=\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2017\/03\/magelis-1024x783.jpg\" alt=\"Magelis HMIs\" width=\"604\" height=\"462\" srcset=\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2017\/03\/magelis-1024x783.jpg 1024w, https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2017\/03\/magelis-300x229.jpg 300w, https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2017\/03\/magelis-768x587.jpg 768w\" sizes=\"auto, (max-width: 604px) 100vw, 604px\" \/><figcaption class=\"caption wp-caption-text\">Magelis HMIs<\/figcaption><\/figure>\n<p><strong>Why is the Magelis <a href=\"https:\/\/www.mroelectric.com\/product\/XBTRT511\">XBTRT511<\/a> is not giving me the correct floating point value reading on the alphanumeric display when communicating with a Momentum?<\/strong><br \/>\nIf you address the alphanumeric display as a %MW that is incorrect. To read a floating point value, you need to address the alphanumeric as a %MF.<\/p>\n<p><strong>Does the Magelis Panel PC, HMIPUC9D0E01, have line out to connect a speaker?<\/strong><br \/>\nYes, the Panel PC <a href=\"https:\/\/www.mroelectric.com\/product\/HMIPUC9D0E01\">HMIPUC9D0E01<\/a> have a Line out to connect an external speaker.<\/p>\n<p><strong>Can I lose my alarms log in Vijeo Designer V4.5 when power cycling my Magelis XBT-GT?<br \/>\n<\/strong>Each alarm group can have 2 such alarm buffers: one for History alarm events (size defined by the &#8220;Num of History Alarms&#8221; property) and one for Log alarm events (size defined by the &#8220;Num of Log Alarms&#8221; property).<br \/>\nThese alarm buffers are stored in the DRAM (Dynamic RAM: similar to the RAM of a PC) of the target. Therefore, if the target is turned off, the alarm buffers are wiped out. If you need them to be saved even when the target is turned off, you can enable the &#8220;Backup Alarm Group&#8221; property (at the global alarm level). This way, these alarm buffers will be stored in the DRAM and in the SRAM (Static RAM: doesn t get wiped out when the target is turned off) as well.<br \/>\nSince the size of these alarm buffers is limited (the maximum value for the &#8220;Num of History Alarms&#8221; and &#8220;Num of Log Alarms&#8221; properties is 10000), they won t always contain the whole history of alarm events on the target. To obtain that behavior, you can enable the &#8220;Save To File&#8221; property (at the alarm group level). This way, the alarm events will be saved into Excel files (on the CF card) and these Excel files will contain the whole history of alarm events for the corresponding alarm groups.<\/p>\n<p><strong>Is there a RS-485 cable to connect a M221 to a Magelis <a href=\"https:\/\/www.mroelectric.com\/product\/XBTN401\">XBTN401<\/a>?<br \/>\n<\/strong>No. There is no cable you must make your own the pin out is as follows;<\/p>\n<p>4&#8212;&#8212;&#8211;4<br \/>\n5&#8212;&#8212;&#8211;5<br \/>\n7&#8212;&#8212;&#8211;7<br \/>\n8&#8212;&#8212;&#8211;8<\/p>\n<p>No other pins can be used because the M221 can also be configured for RS-232. (can not use a straight through Ethernet cable).<\/p>\n<p><strong>What is the meaning of &#8220;PLC Returned error code 02H&#8221; for Magelis Targets HMIGTO ?<\/strong>The error &#8220;PLC Returned error code 02H&#8221;, means that you are trying to access an address in the slave device which is not defined or inaccessible or there can be issue with communication card , cable, or communication settings done inside IOmanager communication equipment channels must be checked. Mostly the issue observed is related to register mismatch between target and slave device. Correcting this will resolve the issues.<\/p>\n<p><strong>What is the the number of candela per square meter for the Magelis XBTGTO?<\/strong><br \/>\nHMIGTO 3.5&#8243; = 450<br \/>\nHMIGTO 5.7&#8243; = 500<br \/>\nHMIGTO 7&#8243; = 350<br \/>\nHMIGTO 7.5&#8243; = 400<br \/>\nHMIGTO 10.4&#8243; = 450<br \/>\nHMIGTO 12.1&#8243; = 450<\/p>\n<p><strong>Can a Magelis HMI communicate to a M241 SL2 using SoMachine protocol?<\/strong><br \/>\nThe M241 can communicate to an HMI via SL2. The default communication settings for SL2 does not match the settings for the COM of the HMI (baud rate and parity are different). If the settings are adapted, the communication works fine.<br \/>\nBelow is the RS485 pinout:<\/p>\n<p>HMI to M241 SL2<br \/>\nPin 4 to D1<br \/>\nPin 5 to D0<\/p>\n<p><strong>Can the Magelis <a href=\"https:\/\/www.mroelectric.com\/product\/HMIPPF7A2701\">HMIPPF7A2701<\/a> be mounted at a 45 degree angle?<\/strong><br \/>\nThe unit can be mounted at a 45 degree angle as long as the ambient air temperature does not exceed 85F and that there is enough air flow surrounding the unit.<\/p>\n<p><strong>Why does Magelis HMI tell me to change my password when I log in?<\/strong><br \/>\nIn Vijeo Designer, there is a feature called Password Management. If this is enabled, and password expiry is enabled, your password will expiry in two cases:<br \/>\n1) At first login and<br \/>\n2) After the defined time has elapsed.<\/p>\n<p>You will need to change your password in the runtime with the user manager part or redownload the application again.<\/p>\n<p><strong>Can I have two Magelis HMI to the same serial port of a M238?<br \/>\n<\/strong>No you cannot, there are two possibilities to realize configuration of a M238 + 2 XBTGTs.<br \/>\nYou can connect an HMI to the SL1 of the M238 and the second HMI can be connected to SL2.<\/p>\n<p><strong>Why is there only some data logged in my Magelis HMI?<\/strong><br \/>\nVijeo Designer Runtime is designed to optimize storage for data logging by only creating a record when the value of the variable changes. If the value of the variable remains static, a new record will not be created (other than the initial record). Each record made is for a unique value. Vijeo Designer cannot send emails via SMTP2Go on the Magelis but is successful via simulation<\/p>\n<p>When this situation occurs, it is likely the network settings on the HMI are incorrect. Ensure that the IP, Subnet Mask, Default Gateway, and DNS server are all set up correctly. Typically you can compare your PC&#8217;s settings vs the HMI&#8217;s settings to find the differences (if they are on the same network).<\/p>\n<p><strong>Can the TM2 expansion modules be used on the Magelis STU and STO?<br \/>\n<\/strong>No, if you want an HMI that can use the TM2 modules you will need to go to the HMISCU series.<\/p>\n<p><strong>Is there a Magelis HMI that can withstand 80psi of pressure?<br \/>\n<\/strong>The HMIGTO xx15 series has been tested to withstand 10 bar of high pressure washing machinery. (10bar = 145 psi)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>MRO Electric carries new and refurbished Magelis HMIs. To request a quote, please call 800-691-8511 or email sales@mroelectric.com. Why is the Magelis XBTRT511 is not giving me the correct floating point value reading on the alphanumeric display when communicating with a Momentum? If you address the alphanumeric display as a %MW that is incorrect. To [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"","_lmt_disable":"","_exactmetrics_skip_tracking":false,"_exactmetrics_sitenote_active":false,"_exactmetrics_sitenote_note":"","_exactmetrics_sitenote_category":0,"ngg_post_thumbnail":0,"footnotes":""},"categories":[96,12],"tags":[500,572],"class_list":["post-1589","post","type-post","status-publish","format-standard","hentry","category-schneider-electric","category-troubleshooting-and-repair","tag-displays","tag-magelis"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v25.3.1 (Yoast SEO v25.3.1) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Schneider Electric Magelis HMIs - Frequently Asked Questions Part II<\/title>\n<meta name=\"description\" content=\"Frequently Asked Questions regarding Schneider Electric Magelis HMIs. This includes troubleshooting and technical information regarding firmware &amp; software.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.mroelectric.com\/blog\/magelis-faq-ii\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Schneider Electric Magelis HMIs - Frequently Asked Questions Part II\" \/>\n<meta property=\"og:description\" content=\"Frequently Asked Questions regarding Schneider Electric Magelis HMIs. This includes troubleshooting and technical information regarding firmware &amp; software.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.mroelectric.com\/blog\/magelis-faq-ii\/\" \/>\n<meta property=\"og:site_name\" content=\"MRO Electric Blog\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/mroelectric\/\" \/>\n<meta property=\"article:published_time\" content=\"2017-03-31T14:40:35+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-03-05T16:02:45+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2017\/03\/magelis-1024x783.jpg\" \/>\n<meta name=\"author\" content=\"Joe Kaminski\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@mroelectric\" \/>\n<meta name=\"twitter:site\" content=\"@mroelectric\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Joe Kaminski\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/magelis-faq-ii\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/magelis-faq-ii\/\"},\"author\":{\"name\":\"Joe Kaminski\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/b993515a2417163a23dfe88597c8d13a\"},\"headline\":\"Schneider Electric Magelis HMIs &#8211; Frequently Asked Questions Part II\",\"datePublished\":\"2017-03-31T14:40:35+00:00\",\"dateModified\":\"2020-03-05T16:02:45+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/magelis-faq-ii\/\"},\"wordCount\":932,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#organization\"},\"image\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/magelis-faq-ii\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2017\/03\/magelis-1024x783.jpg\",\"keywords\":[\"Displays\",\"Magelis\"],\"articleSection\":[\"Schneider Electric\",\"Troubleshooting &amp; Repair\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/www.mroelectric.com\/blog\/magelis-faq-ii\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/magelis-faq-ii\/\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/magelis-faq-ii\/\",\"name\":\"Schneider Electric Magelis HMIs - Frequently Asked Questions Part II\",\"isPartOf\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/magelis-faq-ii\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/magelis-faq-ii\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2017\/03\/magelis-1024x783.jpg\",\"datePublished\":\"2017-03-31T14:40:35+00:00\",\"dateModified\":\"2020-03-05T16:02:45+00:00\",\"description\":\"Frequently Asked Questions regarding Schneider Electric Magelis HMIs. This includes troubleshooting and technical information regarding firmware & software.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/magelis-faq-ii\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.mroelectric.com\/blog\/magelis-faq-ii\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/magelis-faq-ii\/#primaryimage\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2017\/03\/magelis.jpg\",\"contentUrl\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2017\/03\/magelis.jpg\",\"width\":3119,\"height\":2384,\"caption\":\"Magelis HMIs\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/magelis-faq-ii\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.mroelectric.com\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Schneider Electric Magelis HMIs &#8211; Frequently Asked Questions Part II\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#website\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/\",\"name\":\"MRO Electric Blog\",\"description\":\"Applications of PLCs, CNCs, and more!\",\"publisher\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.mroelectric.com\/blog\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#organization\",\"name\":\"MRO Electric and Supply\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro-logo-new_large2_blue-1.png\",\"contentUrl\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro-logo-new_large2_blue-1.png\",\"width\":430,\"height\":222,\"caption\":\"MRO Electric and Supply\"},\"image\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/mroelectric\/\",\"https:\/\/x.com\/mroelectric\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/b993515a2417163a23dfe88597c8d13a\",\"name\":\"Joe Kaminski\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/fb7c0d641ed541ad912b27609e8079304fc356be7b5b53578b32ad3fa973f506?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/fb7c0d641ed541ad912b27609e8079304fc356be7b5b53578b32ad3fa973f506?s=96&d=mm&r=g\",\"caption\":\"Joe Kaminski\"},\"description\":\"Joe Kaminski is an industrial automation specialist at MRO Electric. He has a background in industrial engineering and supply chain management. Joe has worked in the automation industry for over 10 years providing support to some of the largest companies in the world. For more info, visit www.mroelectric.com.\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/author\/jadmin\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Schneider Electric Magelis HMIs - Frequently Asked Questions Part II","description":"Frequently Asked Questions regarding Schneider Electric Magelis HMIs. This includes troubleshooting and technical information regarding firmware & software.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.mroelectric.com\/blog\/magelis-faq-ii\/","og_locale":"en_US","og_type":"article","og_title":"Schneider Electric Magelis HMIs - Frequently Asked Questions Part II","og_description":"Frequently Asked Questions regarding Schneider Electric Magelis HMIs. This includes troubleshooting and technical information regarding firmware & software.","og_url":"https:\/\/www.mroelectric.com\/blog\/magelis-faq-ii\/","og_site_name":"MRO Electric Blog","article_publisher":"https:\/\/www.facebook.com\/mroelectric\/","article_published_time":"2017-03-31T14:40:35+00:00","article_modified_time":"2020-03-05T16:02:45+00:00","og_image":[{"url":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2017\/03\/magelis-1024x783.jpg","type":"","width":"","height":""}],"author":"Joe Kaminski","twitter_card":"summary_large_image","twitter_creator":"@mroelectric","twitter_site":"@mroelectric","twitter_misc":{"Written by":"Joe Kaminski","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.mroelectric.com\/blog\/magelis-faq-ii\/#article","isPartOf":{"@id":"https:\/\/www.mroelectric.com\/blog\/magelis-faq-ii\/"},"author":{"name":"Joe Kaminski","@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/b993515a2417163a23dfe88597c8d13a"},"headline":"Schneider Electric Magelis HMIs &#8211; Frequently Asked Questions Part II","datePublished":"2017-03-31T14:40:35+00:00","dateModified":"2020-03-05T16:02:45+00:00","mainEntityOfPage":{"@id":"https:\/\/www.mroelectric.com\/blog\/magelis-faq-ii\/"},"wordCount":932,"commentCount":0,"publisher":{"@id":"https:\/\/www.mroelectric.com\/blog\/#organization"},"image":{"@id":"https:\/\/www.mroelectric.com\/blog\/magelis-faq-ii\/#primaryimage"},"thumbnailUrl":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2017\/03\/magelis-1024x783.jpg","keywords":["Displays","Magelis"],"articleSection":["Schneider Electric","Troubleshooting &amp; Repair"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.mroelectric.com\/blog\/magelis-faq-ii\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.mroelectric.com\/blog\/magelis-faq-ii\/","url":"https:\/\/www.mroelectric.com\/blog\/magelis-faq-ii\/","name":"Schneider Electric Magelis HMIs - Frequently Asked Questions Part II","isPartOf":{"@id":"https:\/\/www.mroelectric.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.mroelectric.com\/blog\/magelis-faq-ii\/#primaryimage"},"image":{"@id":"https:\/\/www.mroelectric.com\/blog\/magelis-faq-ii\/#primaryimage"},"thumbnailUrl":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2017\/03\/magelis-1024x783.jpg","datePublished":"2017-03-31T14:40:35+00:00","dateModified":"2020-03-05T16:02:45+00:00","description":"Frequently Asked Questions regarding Schneider Electric Magelis HMIs. This includes troubleshooting and technical information regarding firmware & software.","breadcrumb":{"@id":"https:\/\/www.mroelectric.com\/blog\/magelis-faq-ii\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.mroelectric.com\/blog\/magelis-faq-ii\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mroelectric.com\/blog\/magelis-faq-ii\/#primaryimage","url":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2017\/03\/magelis.jpg","contentUrl":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2017\/03\/magelis.jpg","width":3119,"height":2384,"caption":"Magelis HMIs"},{"@type":"BreadcrumbList","@id":"https:\/\/www.mroelectric.com\/blog\/magelis-faq-ii\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.mroelectric.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Schneider Electric Magelis HMIs &#8211; Frequently Asked Questions Part II"}]},{"@type":"WebSite","@id":"https:\/\/www.mroelectric.com\/blog\/#website","url":"https:\/\/www.mroelectric.com\/blog\/","name":"MRO Electric Blog","description":"Applications of PLCs, CNCs, and more!","publisher":{"@id":"https:\/\/www.mroelectric.com\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.mroelectric.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.mroelectric.com\/blog\/#organization","name":"MRO Electric and Supply","url":"https:\/\/www.mroelectric.com\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro-logo-new_large2_blue-1.png","contentUrl":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro-logo-new_large2_blue-1.png","width":430,"height":222,"caption":"MRO Electric and Supply"},"image":{"@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/mroelectric\/","https:\/\/x.com\/mroelectric"]},{"@type":"Person","@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/b993515a2417163a23dfe88597c8d13a","name":"Joe Kaminski","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/fb7c0d641ed541ad912b27609e8079304fc356be7b5b53578b32ad3fa973f506?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/fb7c0d641ed541ad912b27609e8079304fc356be7b5b53578b32ad3fa973f506?s=96&d=mm&r=g","caption":"Joe Kaminski"},"description":"Joe Kaminski is an industrial automation specialist at MRO Electric. He has a background in industrial engineering and supply chain management. Joe has worked in the automation industry for over 10 years providing support to some of the largest companies in the world. For more info, visit www.mroelectric.com.","url":"https:\/\/www.mroelectric.com\/blog\/author\/jadmin\/"}]}},"modified_by":"Brian Hughes","_links":{"self":[{"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/posts\/1589","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/comments?post=1589"}],"version-history":[{"count":5,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/posts\/1589\/revisions"}],"predecessor-version":[{"id":4484,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/posts\/1589\/revisions\/4484"}],"wp:attachment":[{"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/media?parent=1589"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/categories?post=1589"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/tags?post=1589"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}