{"id":166,"date":"2015-04-08T14:52:07","date_gmt":"2015-04-08T14:52:07","guid":{"rendered":"http:\/\/www.mroelectric.com\/blog\/?p=166"},"modified":"2020-03-04T15:13:26","modified_gmt":"2020-03-04T20:13:26","slug":"fanuc-911-error","status":"publish","type":"post","link":"https:\/\/www.mroelectric.com\/blog\/fanuc-911-error\/","title":{"rendered":"Fanuc 911 RAM PARITY ERROR Troubleshooting"},"content":{"rendered":"<h2><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-2528 size-full\" src=\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro_fanuccnc_series-1.jpg\" alt=\"Fanuc 911 Error\" width=\"400\" height=\"318\" srcset=\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro_fanuccnc_series-1.jpg 400w, https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro_fanuccnc_series-1-300x239.jpg 300w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/h2>\n<h2>Fanuc 911 RAM PARITY ERROR Troubleshooting<\/h2>\n<h5>MRO Electric and Supply maintains a comprehensive stock of new and used <a href=\"https:\/\/www.mroelectric.com\/fanuc\/automation\/1\">FANUC CNC<\/a> and <a href=\"https:\/\/www.mroelectric.com\/fanuc\/robotics\/1\">FANUC Robots<\/a> parts. If you need a FANUC replacement part, please call 800-691-8511 or email <a href=\"mailto:sales@mroelectric.com\">sales@mroelectric.com<\/a>.<\/h5>\n<p>Last week we had a customer who was running an RNC 16 STAR 1990 vintage machine which failed so he decided to replace the main <a href=\"https:\/\/www.mroelectric.com\/product\/A16B-1010-0280\">A16B-1010-0280<\/a> motherboard. His original problem was that he was receiving a 401 [VRDY Off] Error which then led to a 911 Error. When he replaced the A16B-1010-0280 motherboard, the machine would go directly to the 911 Error.<\/p>\n<p>The first thing we checked for was to make sure that he transferred over all of the EEPROM modules from his original board to the replacement board, which he did. Since that wasn&#8217;t the issue, we double checked on the 911 Error, which shows as a RAM PARITY ERROR in the manual. The main cause of this error is an issue with the memory in the unit, which is caused by the memory board failing or losing the parameters in the system.<\/p>\n<p>To check to see if the <a href=\"https:\/\/www.mroelectric.com\/fanuc\/robotics\/pcbs\/1\">memory board<\/a> was causing it or not, you can turn the control off, reset it, and delete the parameters. If this clears the alarm, the control would come up with a different series of servo alarms meaning that the parameters need to be reloaded. If the Fanuc 911 Error comes back it would mean that there is a problem with the memory board which needs to be replaced. Before trying any of this, be sure to confirm that you have all of the parameters saved so you can load them back in. Check out our article on IT and Robotics here.<\/p>\n<p>Once the 911 Error was cleared, the customer was able to load the parameters back on to get the machine up and running.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Fanuc 911 RAM PARITY ERROR Troubleshooting MRO Electric and Supply maintains a comprehensive stock of new and used FANUC CNC and FANUC Robots parts. If you need a FANUC replacement part, please call 800-691-8511 or email sales@mroelectric.com. Last week we had a customer who was running an RNC 16 STAR 1990 vintage machine which failed [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"","_lmt_disable":"","_exactmetrics_skip_tracking":false,"_exactmetrics_sitenote_active":false,"_exactmetrics_sitenote_note":"","_exactmetrics_sitenote_category":0,"ngg_post_thumbnail":0,"footnotes":""},"categories":[77,497,12],"tags":[67],"class_list":["post-166","post","type-post","status-publish","format-standard","hentry","category-fanuc","category-robotics-applications","category-troubleshooting-and-repair","tag-alarm-and-fault-codes"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v25.3.1 (Yoast SEO v25.3.1) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Fanuc 911 Error - RAM PARITY ERROR | Troubleshooting and Tips<\/title>\n<meta name=\"description\" content=\"Tips for clearing out a Fanuc 911 Error on an A16B-1010-0280 mother board. If you need a replacement unit, please let us supply you with one.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.mroelectric.com\/blog\/fanuc-911-error\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Fanuc 911 RAM PARITY ERROR Troubleshooting\" \/>\n<meta property=\"og:description\" content=\"Tips for clearing out a Fanuc 911 Error on an A16B-1010-0280 mother board. If you need a replacement unit, please let us supply you with one.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.mroelectric.com\/blog\/fanuc-911-error\/\" \/>\n<meta property=\"og:site_name\" content=\"MRO Electric Blog\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/mroelectric\/\" \/>\n<meta property=\"article:published_time\" content=\"2015-04-08T14:52:07+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-03-04T20:13:26+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro_fanuccnc_series-1.jpg\" \/>\n<meta name=\"author\" content=\"Joe Kaminski\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@mroelectric\" \/>\n<meta name=\"twitter:site\" content=\"@mroelectric\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Joe Kaminski\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/fanuc-911-error\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/fanuc-911-error\/\"},\"author\":{\"name\":\"Joe Kaminski\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/b993515a2417163a23dfe88597c8d13a\"},\"headline\":\"Fanuc 911 RAM PARITY ERROR Troubleshooting\",\"datePublished\":\"2015-04-08T14:52:07+00:00\",\"dateModified\":\"2020-03-04T20:13:26+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/fanuc-911-error\/\"},\"wordCount\":315,\"commentCount\":4,\"publisher\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#organization\"},\"image\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/fanuc-911-error\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro_fanuccnc_series-1.jpg\",\"keywords\":[\"Alarms &amp; Faults\"],\"articleSection\":[\"Fanuc\",\"Robotics Applications\",\"Troubleshooting &amp; Repair\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/www.mroelectric.com\/blog\/fanuc-911-error\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/fanuc-911-error\/\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/fanuc-911-error\/\",\"name\":\"Fanuc 911 Error - RAM PARITY ERROR | Troubleshooting and Tips\",\"isPartOf\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/fanuc-911-error\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/fanuc-911-error\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro_fanuccnc_series-1.jpg\",\"datePublished\":\"2015-04-08T14:52:07+00:00\",\"dateModified\":\"2020-03-04T20:13:26+00:00\",\"description\":\"Tips for clearing out a Fanuc 911 Error on an A16B-1010-0280 mother board. If you need a replacement unit, please let us supply you with one.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/fanuc-911-error\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.mroelectric.com\/blog\/fanuc-911-error\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/fanuc-911-error\/#primaryimage\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro_fanuccnc_series-1.jpg\",\"contentUrl\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro_fanuccnc_series-1.jpg\",\"width\":400,\"height\":318,\"caption\":\"fanuc cnc\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/fanuc-911-error\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.mroelectric.com\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Fanuc 911 RAM PARITY ERROR Troubleshooting\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#website\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/\",\"name\":\"MRO Electric Blog\",\"description\":\"Applications of PLCs, CNCs, and more!\",\"publisher\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.mroelectric.com\/blog\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#organization\",\"name\":\"MRO Electric and Supply\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro-logo-new_large2_blue-1.png\",\"contentUrl\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro-logo-new_large2_blue-1.png\",\"width\":430,\"height\":222,\"caption\":\"MRO Electric and Supply\"},\"image\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/mroelectric\/\",\"https:\/\/x.com\/mroelectric\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/b993515a2417163a23dfe88597c8d13a\",\"name\":\"Joe Kaminski\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/fb7c0d641ed541ad912b27609e8079304fc356be7b5b53578b32ad3fa973f506?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/fb7c0d641ed541ad912b27609e8079304fc356be7b5b53578b32ad3fa973f506?s=96&d=mm&r=g\",\"caption\":\"Joe Kaminski\"},\"description\":\"Joe Kaminski is an industrial automation specialist at MRO Electric. He has a background in industrial engineering and supply chain management. Joe has worked in the automation industry for over 10 years providing support to some of the largest companies in the world. For more info, visit www.mroelectric.com.\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/author\/jadmin\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Fanuc 911 Error - RAM PARITY ERROR | Troubleshooting and Tips","description":"Tips for clearing out a Fanuc 911 Error on an A16B-1010-0280 mother board. If you need a replacement unit, please let us supply you with one.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.mroelectric.com\/blog\/fanuc-911-error\/","og_locale":"en_US","og_type":"article","og_title":"Fanuc 911 RAM PARITY ERROR Troubleshooting","og_description":"Tips for clearing out a Fanuc 911 Error on an A16B-1010-0280 mother board. If you need a replacement unit, please let us supply you with one.","og_url":"https:\/\/www.mroelectric.com\/blog\/fanuc-911-error\/","og_site_name":"MRO Electric Blog","article_publisher":"https:\/\/www.facebook.com\/mroelectric\/","article_published_time":"2015-04-08T14:52:07+00:00","article_modified_time":"2020-03-04T20:13:26+00:00","og_image":[{"url":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro_fanuccnc_series-1.jpg","type":"","width":"","height":""}],"author":"Joe Kaminski","twitter_card":"summary_large_image","twitter_creator":"@mroelectric","twitter_site":"@mroelectric","twitter_misc":{"Written by":"Joe Kaminski","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.mroelectric.com\/blog\/fanuc-911-error\/#article","isPartOf":{"@id":"https:\/\/www.mroelectric.com\/blog\/fanuc-911-error\/"},"author":{"name":"Joe Kaminski","@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/b993515a2417163a23dfe88597c8d13a"},"headline":"Fanuc 911 RAM PARITY ERROR Troubleshooting","datePublished":"2015-04-08T14:52:07+00:00","dateModified":"2020-03-04T20:13:26+00:00","mainEntityOfPage":{"@id":"https:\/\/www.mroelectric.com\/blog\/fanuc-911-error\/"},"wordCount":315,"commentCount":4,"publisher":{"@id":"https:\/\/www.mroelectric.com\/blog\/#organization"},"image":{"@id":"https:\/\/www.mroelectric.com\/blog\/fanuc-911-error\/#primaryimage"},"thumbnailUrl":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro_fanuccnc_series-1.jpg","keywords":["Alarms &amp; Faults"],"articleSection":["Fanuc","Robotics Applications","Troubleshooting &amp; Repair"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.mroelectric.com\/blog\/fanuc-911-error\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.mroelectric.com\/blog\/fanuc-911-error\/","url":"https:\/\/www.mroelectric.com\/blog\/fanuc-911-error\/","name":"Fanuc 911 Error - RAM PARITY ERROR | Troubleshooting and Tips","isPartOf":{"@id":"https:\/\/www.mroelectric.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.mroelectric.com\/blog\/fanuc-911-error\/#primaryimage"},"image":{"@id":"https:\/\/www.mroelectric.com\/blog\/fanuc-911-error\/#primaryimage"},"thumbnailUrl":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro_fanuccnc_series-1.jpg","datePublished":"2015-04-08T14:52:07+00:00","dateModified":"2020-03-04T20:13:26+00:00","description":"Tips for clearing out a Fanuc 911 Error on an A16B-1010-0280 mother board. If you need a replacement unit, please let us supply you with one.","breadcrumb":{"@id":"https:\/\/www.mroelectric.com\/blog\/fanuc-911-error\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.mroelectric.com\/blog\/fanuc-911-error\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mroelectric.com\/blog\/fanuc-911-error\/#primaryimage","url":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro_fanuccnc_series-1.jpg","contentUrl":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro_fanuccnc_series-1.jpg","width":400,"height":318,"caption":"fanuc cnc"},{"@type":"BreadcrumbList","@id":"https:\/\/www.mroelectric.com\/blog\/fanuc-911-error\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.mroelectric.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Fanuc 911 RAM PARITY ERROR Troubleshooting"}]},{"@type":"WebSite","@id":"https:\/\/www.mroelectric.com\/blog\/#website","url":"https:\/\/www.mroelectric.com\/blog\/","name":"MRO Electric Blog","description":"Applications of PLCs, CNCs, and more!","publisher":{"@id":"https:\/\/www.mroelectric.com\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.mroelectric.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.mroelectric.com\/blog\/#organization","name":"MRO Electric and Supply","url":"https:\/\/www.mroelectric.com\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro-logo-new_large2_blue-1.png","contentUrl":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro-logo-new_large2_blue-1.png","width":430,"height":222,"caption":"MRO Electric and Supply"},"image":{"@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/mroelectric\/","https:\/\/x.com\/mroelectric"]},{"@type":"Person","@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/b993515a2417163a23dfe88597c8d13a","name":"Joe Kaminski","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/fb7c0d641ed541ad912b27609e8079304fc356be7b5b53578b32ad3fa973f506?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/fb7c0d641ed541ad912b27609e8079304fc356be7b5b53578b32ad3fa973f506?s=96&d=mm&r=g","caption":"Joe Kaminski"},"description":"Joe Kaminski is an industrial automation specialist at MRO Electric. He has a background in industrial engineering and supply chain management. Joe has worked in the automation industry for over 10 years providing support to some of the largest companies in the world. For more info, visit www.mroelectric.com.","url":"https:\/\/www.mroelectric.com\/blog\/author\/jadmin\/"}]}},"modified_by":"Brian Hughes","_links":{"self":[{"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/posts\/166","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/comments?post=166"}],"version-history":[{"count":8,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/posts\/166\/revisions"}],"predecessor-version":[{"id":4438,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/posts\/166\/revisions\/4438"}],"wp:attachment":[{"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/media?parent=166"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/categories?post=166"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/tags?post=166"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}