{"id":186,"date":"2015-05-01T13:09:35","date_gmt":"2015-05-01T13:09:35","guid":{"rendered":"http:\/\/www.mroelectric.com\/blog\/?p=186"},"modified":"2024-03-20T13:54:54","modified_gmt":"2024-03-20T17:54:54","slug":"fanuc-spindle-alarms","status":"publish","type":"post","link":"https:\/\/www.mroelectric.com\/blog\/fanuc-spindle-alarms\/","title":{"rendered":"Fanuc Spindle Alarms for Troubleshooting"},"content":{"rendered":"<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-3963 size-full aligncenter\" src=\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/A06B-6079-H106.jpg\" alt=\"A06B-6079-H106\" width=\"217\" height=\"375\" srcset=\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/A06B-6079-H106.jpg 217w, https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/A06B-6079-H106-174x300.jpg 174w\" sizes=\"auto, (max-width: 217px) 100vw, 217px\" \/><\/p>\n<table  class=\" table table-hover\" >\n<tbody>\n<tr>\n<th rowspan=\"2\">Alarm #<\/th>\n<th colspan=\"4\">Led Display<\/th>\n<th rowspan=\"2\">Content of <a href=\"https:\/\/www.mroelectric.com\/fanuc\/automation\/spindle-amplifiers\/1\">FANUC SPINDLE Alarms<\/a><\/th>\n<\/tr>\n<tr>\n<th>8<\/th>\n<th>4<\/th>\n<th>2<\/th>\n<th width=\"36\">1<\/th>\n<\/tr>\n<tr>\n<td width=\"55\">\n<p align=\"center\">1<\/p>\n<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"391\">Motor Overheat<\/td>\n<\/tr>\n<tr>\n<td width=\"55\">\n<p align=\"center\">2<\/p>\n<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"391\">Speed deviates from commanded speed<\/td>\n<\/tr>\n<tr>\n<td width=\"55\">\n<p align=\"center\">3<\/p>\n<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"391\">Regenerative fault<\/td>\n<\/tr>\n<tr>\n<td width=\"55\">\n<p align=\"center\">6<\/p>\n<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"391\">Excess Motor Speed Analog<\/td>\n<\/tr>\n<tr>\n<td width=\"55\">\n<p align=\"center\">7<\/p>\n<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"391\">Excess Motor Speed Digital<\/td>\n<\/tr>\n<tr>\n<td width=\"55\">\n<p align=\"center\">8<\/p>\n<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"391\">Voltage higher than specified<\/td>\n<\/tr>\n<tr>\n<td width=\"55\">\n<p align=\"center\">9<\/p>\n<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"391\">Radiator for power semiconductor overheat<\/td>\n<\/tr>\n<tr>\n<td width=\"55\">\n<p align=\"center\">10<\/p>\n<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"391\">+15Volt Supply is low<\/td>\n<\/tr>\n<tr>\n<td width=\"55\">\n<p align=\"center\">11<\/p>\n<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"391\">DC Link voltage is high<\/td>\n<\/tr>\n<tr>\n<td width=\"55\">\n<p align=\"center\">12<\/p>\n<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"391\">DC Link current is high<\/td>\n<\/tr>\n<tr>\n<td width=\"55\">\n<p align=\"center\">13<\/p>\n<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"391\">CPU and peripheral parts are defective<\/td>\n<\/tr>\n<tr>\n<td width=\"55\">\n<p align=\"center\">14<\/p>\n<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"391\">ROM is defective<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Alarm List for&nbsp;A06B-6044-Hxxx<\/h3>\n<p>Alarm List for the following Drives:<\/p>\n<ul>\n<li>Model 3 thru Model 40&nbsp;&nbsp;&nbsp;A06B-6044-Hxxx<\/li>\n<li>\n<h6>MRO Electric and Supply maintains a comprehensive stock of new and used <a style=\"font-family: Bitter, Georgia, serif;\" href=\"https:\/\/www.mroelectric.com\/fanuc\/automation\/1\">FANUC CNC parts&nbsp;<\/a><span style=\"font-family: Bitter, Georgia, serif;\">including <\/span><a style=\"font-family: Bitter, Georgia, serif;\" href=\"https:\/\/www.mroelectric.com\/fanuc\/automation\/spindle-amplifiers\/1\">FANUC Spindle Amps<\/a><span style=\"font-family: Bitter, Georgia, serif;\">. If you need a replacement part, please call 800-691-8511 or email <\/span><a style=\"font-family: Bitter, Georgia, serif;\" href=\"mailto:sales@mroelectric.com\">sales@mroelectric.com<\/a><span style=\"font-family: Bitter, Georgia, serif;\">.<\/span><\/h6>\n<\/li>\n<\/ul>\n<table  class=\" table table-hover\" >\n<tbody>\n<tr>\n<th rowspan=\"2\" width=\"55\">Alarm #<\/th>\n<th colspan=\"4\" width=\"144\">Led Display<\/th>\n<th rowspan=\"2\" width=\"391\">Content of Alarms<\/th>\n<\/tr>\n<tr>\n<th width=\"36\">8<\/th>\n<th width=\"36\">4<\/th>\n<th width=\"36\">2<\/th>\n<th width=\"36\">1<\/th>\n<\/tr>\n<tr>\n<td width=\"55\">\n<p align=\"center\">1<\/p>\n<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"391\">Motor Overheat<\/td>\n<\/tr>\n<tr>\n<td width=\"55\">\n<p align=\"center\">2<\/p>\n<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"391\">Speed deviates from commanded speed<\/td>\n<\/tr>\n<tr>\n<td width=\"55\">\n<p align=\"center\">3<\/p>\n<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"391\">Fuse F7in DC link is blown out.<\/td>\n<\/tr>\n<tr>\n<td width=\"55\">\n<p align=\"center\">4<\/p>\n<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"391\">Fuses F1,F2,F3 for AC input blown out.<\/td>\n<\/tr>\n<tr>\n<td width=\"55\">\n<p align=\"center\">5<\/p>\n<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"391\">Fuses AF2 or AF3 on PCB are blown out.<\/td>\n<\/tr>\n<tr>\n<td width=\"55\">\n<p align=\"center\">6<\/p>\n<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"391\">Excess Motor Speed Analog<\/td>\n<\/tr>\n<tr>\n<td width=\"55\">\n<p align=\"center\">7<\/p>\n<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"391\">Excess Motor Speed Digital<\/td>\n<\/tr>\n<tr>\n<td width=\"55\">\n<p align=\"center\">8<\/p>\n<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"391\">Voltage higher than specified (24v)<\/td>\n<\/tr>\n<tr>\n<td width=\"55\">\n<p align=\"center\">9<\/p>\n<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"391\">Radiator for power semiconductor overheat<\/td>\n<\/tr>\n<tr>\n<td width=\"55\">\n<p align=\"center\">10<\/p>\n<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"391\">+15Volt Supply is low<\/td>\n<\/tr>\n<tr>\n<td width=\"55\">\n<p align=\"center\">11<\/p>\n<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"391\">DC Link voltage is high<\/td>\n<\/tr>\n<tr>\n<td width=\"55\">\n<p align=\"center\">12<\/p>\n<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"391\">DC Link current is high<\/td>\n<\/tr>\n<tr>\n<td width=\"55\">\n<p align=\"center\">13<\/p>\n<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"391\">CPU and peripheral parts are defective<\/td>\n<\/tr>\n<tr>\n<td width=\"55\">\n<p align=\"center\">14<\/p>\n<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"36\">&nbsp;<\/td>\n<td width=\"391\">ROM is defective<\/td>\n<\/tr>\n<tr>\n<td width=\"55\">\n<p align=\"center\">15<\/p>\n<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"36\">\n<p align=\"center\">o<\/p>\n<\/td>\n<td width=\"391\">Option circuit fault.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Digital AC Spindle Drive<\/h2>\n<h3>Alarm List for&nbsp;A06B-6055-Hxxx<\/h3>\n<p>Alarm List for the following drives:<\/p>\n<ul>\n<li>Model 3 thru 22&nbsp;&nbsp;&nbsp;&nbsp;A06B-6055-Hxxx<\/li>\n<\/ul>\n<p><b>&nbsp;<\/b><\/p>\n<table  class=\" table table-hover\" >\n<tbody>\n<tr>\n<th width=\"127\">Alarm Display<\/th>\n<th width=\"463\">Alarm Content<\/th>\n<\/tr>\n<tr>\n<td width=\"127\">\n<p align=\"center\">AL-01<\/p>\n<\/td>\n<td width=\"463\">Motor Overheated<\/td>\n<\/tr>\n<tr>\n<td width=\"127\">\n<p align=\"center\">AL-02<\/p>\n<\/td>\n<td width=\"463\">Speed deviates from commanded speed<\/td>\n<\/tr>\n<tr>\n<td width=\"127\">\n<p align=\"center\">AL-03<\/p>\n<\/td>\n<td width=\"463\">Fuse F7in DC link is blown out.<\/td>\n<\/tr>\n<tr>\n<td width=\"127\">\n<p align=\"center\">AL-04<\/p>\n<\/td>\n<td width=\"463\">Fuses F1,F2,F3 for AC input blown out.<\/td>\n<\/tr>\n<tr>\n<td width=\"127\">\n<p align=\"center\">AL-06<\/p>\n<\/td>\n<td width=\"463\">Excess Motor Speed Analog<\/td>\n<\/tr>\n<tr>\n<td width=\"127\">\n<p align=\"center\">AL-07<\/p>\n<\/td>\n<td width=\"463\">Excess Motor Speed Digital<\/td>\n<\/tr>\n<tr>\n<td width=\"127\">\n<p align=\"center\">AL-08<\/p>\n<\/td>\n<td width=\"463\">Voltage higher than specified (24v)<\/td>\n<\/tr>\n<tr>\n<td width=\"127\">\n<p align=\"center\">AL-09<\/p>\n<\/td>\n<td width=\"463\">Radiator for power semiconductor overheat<\/td>\n<\/tr>\n<tr>\n<td width=\"127\">\n<p align=\"center\">AL-10<\/p>\n<\/td>\n<td width=\"463\">+15v power supply is abnormally low<\/td>\n<\/tr>\n<tr>\n<td width=\"127\">\n<p align=\"center\">AL-11<\/p>\n<\/td>\n<td width=\"463\">DC Link voltage is high<\/td>\n<\/tr>\n<tr>\n<td width=\"127\">\n<p align=\"center\">AL-12<\/p>\n<\/td>\n<td width=\"463\">DC Link current is high<\/td>\n<\/tr>\n<tr>\n<td width=\"127\">\n<p align=\"center\">AL-13<\/p>\n<\/td>\n<td width=\"463\">Data memory for CPU abnormal<\/td>\n<\/tr>\n<tr>\n<td width=\"127\">\n<p align=\"center\">AL-16<\/p>\n<\/td>\n<td width=\"463\">RAM in NVRAM is abnormal<\/td>\n<\/tr>\n<tr>\n<td width=\"127\">\n<p align=\"center\">AL-17<\/p>\n<\/td>\n<td width=\"463\">ROM in NVRAM is abnormal<\/td>\n<\/tr>\n<tr>\n<td width=\"127\">\n<p align=\"center\">AL-18<\/p>\n<\/td>\n<td width=\"463\">Check sum alarm of ROM<\/td>\n<\/tr>\n<tr>\n<td width=\"127\">\n<p align=\"center\">AL-19<\/p>\n<\/td>\n<td width=\"463\">Excessive alarm of U phase current detection circuit offset<\/td>\n<\/tr>\n<tr>\n<td width=\"127\">\n<p align=\"center\">AL-20<\/p>\n<\/td>\n<td width=\"463\">Excessive alarm of V phase current detection circuit offset<\/td>\n<\/tr>\n<tr>\n<td width=\"127\">\n<p align=\"center\">AL-21<\/p>\n<\/td>\n<td width=\"463\">Excessive alarm of velocity command circuit offset.<\/td>\n<\/tr>\n<tr>\n<td width=\"127\">\n<p align=\"center\">AL-22<\/p>\n<\/td>\n<td width=\"463\">Excessive alarm of velocity detection circuit offset.<\/td>\n<\/tr>\n<tr>\n<td width=\"127\">\n<p align=\"center\">AL-23<\/p>\n<\/td>\n<td width=\"463\">Excessive alarm of ER circuit offset.<\/td>\n<\/tr>\n<tr>\n<td width=\"127\">\n<p align=\"center\">AL-14<\/p>\n<\/td>\n<td width=\"463\">ROM is abnormal<\/td>\n<\/tr>\n<tr>\n<td width=\"127\">\n<p align=\"center\">AL-15<\/p>\n<\/td>\n<td width=\"463\">Spindle selection control circuit is abnormal.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Alarm List for&nbsp;A06B-6059-Hxxx<\/h3>\n<p>Alarm List for the following drives:<\/p>\n<ul>\n<li>Model 1S thru 3S&nbsp;&nbsp;&nbsp;A06B-6059-Hxxx<\/li>\n<\/ul>\n<p><b>&nbsp;View&nbsp;<strong><a href=\"https:\/\/www.mroelectric.com\/blog\/fanuc-spindle-amp-alarm\/\">Fanuc Spindle Amp Alarm Codes for Alpha Series<\/a> here.&nbsp;<\/strong><\/b><\/p>\n<table  class=\" table table-hover\" >\n<tbody>\n<tr>\n<th width=\"78\">Alarm #<\/th>\n<th width=\"320\">Meaning<\/th>\n<\/tr>\n<tr>\n<td width=\"78\">\n<p align=\"center\">AL-01<\/p>\n<\/td>\n<td width=\"320\">Motor Overheat<\/td>\n<\/tr>\n<tr>\n<td width=\"78\">\n<p align=\"center\">AL-02<\/p>\n<\/td>\n<td width=\"320\">Speed deviates from commanded speed<\/td>\n<\/tr>\n<tr>\n<td width=\"78\">\n<p align=\"center\">AL-03<\/p>\n<\/td>\n<td width=\"320\">24v Fuse is blown. (before PCB edition 09A)<\/td>\n<\/tr>\n<tr>\n<td width=\"78\">\n<p align=\"center\">AL-04<\/p>\n<\/td>\n<td width=\"320\">&nbsp;<\/td>\n<\/tr>\n<tr>\n<td width=\"78\">\n<p align=\"center\">AL-05<\/p>\n<\/td>\n<td width=\"320\">&nbsp;<\/td>\n<\/tr>\n<tr>\n<td width=\"78\">\n<p align=\"center\">AL-06<\/p>\n<\/td>\n<td width=\"320\">Excess Motor Speed Analog<\/td>\n<\/tr>\n<tr>\n<td width=\"78\">\n<p align=\"center\">AL-07<\/p>\n<\/td>\n<td width=\"320\">Excess Motor Speed Digital<\/td>\n<\/tr>\n<tr>\n<td width=\"78\">\n<p align=\"center\">AL-08<\/p>\n<\/td>\n<td width=\"320\">Over voltage<\/td>\n<\/tr>\n<tr>\n<td width=\"78\">\n<p align=\"center\">AL-09<\/p>\n<\/td>\n<td width=\"320\">Overheat of radiator<\/td>\n<\/tr>\n<tr>\n<td width=\"78\">\n<p align=\"center\">AL-10<\/p>\n<\/td>\n<td width=\"320\">Low voltage of input power.<\/td>\n<\/tr>\n<tr>\n<td width=\"78\">\n<p align=\"center\">AL-11<\/p>\n<\/td>\n<td width=\"320\">Excessive high voltage of DC link<\/td>\n<\/tr>\n<tr>\n<td width=\"78\">\n<p align=\"center\">AL-12<\/p>\n<\/td>\n<td width=\"320\">Abnormal current of DC link<\/td>\n<\/tr>\n<tr>\n<td width=\"78\">\n<p align=\"center\">AL-13-15<\/p>\n<\/td>\n<td width=\"320\">&nbsp;<\/td>\n<\/tr>\n<tr>\n<td width=\"78\">\n<p align=\"center\">AL-16-23<\/p>\n<\/td>\n<td width=\"320\">Defective arithmetic circuit and peripheral circuit<\/td>\n<\/tr>\n<tr>\n<td width=\"78\">\n<p align=\"center\">No indication<\/p>\n<\/td>\n<td width=\"320\">Defective ROM<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Alarm List for&nbsp;A06B-6059-Hxxx<\/h3>\n<p>Alarm List for the following drives:<\/p>\n<ul>\n<li>Model 6S-26S&nbsp;&nbsp;&nbsp;&nbsp;A06B-6059-Hxxx<\/li>\n<\/ul>\n<table  class=\" table table-hover\" >\n<tbody>\n<tr>\n<th width=\"78\">Alarm #<\/th>\n<th width=\"320\">Meaning<\/th>\n<\/tr>\n<tr>\n<td width=\"78\">\n<p align=\"center\">AL-01<\/p>\n<\/td>\n<td width=\"320\">Motor Overheat<\/td>\n<\/tr>\n<tr>\n<td width=\"78\">\n<p align=\"center\">AL-02<\/p>\n<\/td>\n<td width=\"320\">Speed deviates from commanded speed<\/td>\n<\/tr>\n<tr>\n<td width=\"78\">\n<p align=\"center\">AL-03<\/p>\n<\/td>\n<td width=\"320\">24v Fuse is blown. (before PCB edition 09A)<\/td>\n<\/tr>\n<tr>\n<td width=\"78\">\n<p align=\"center\">AL-04<\/p>\n<\/td>\n<td width=\"320\">Open phase of input power.<\/td>\n<\/tr>\n<tr>\n<td width=\"78\">\n<p align=\"center\">AL-05<\/p>\n<\/td>\n<td width=\"320\">&nbsp;<\/td>\n<\/tr>\n<tr>\n<td width=\"78\">\n<p align=\"center\">AL-06<\/p>\n<\/td>\n<td width=\"320\">Excess Motor Speed Analog<\/td>\n<\/tr>\n<tr>\n<td width=\"78\">\n<p align=\"center\">AL-07<\/p>\n<\/td>\n<td width=\"320\">Excess Motor Speed Digital<\/td>\n<\/tr>\n<tr>\n<td width=\"78\">\n<p align=\"center\">AL-08<\/p>\n<\/td>\n<td width=\"320\">Over voltage<\/td>\n<\/tr>\n<tr>\n<td width=\"78\">\n<p align=\"center\">AL-09<\/p>\n<\/td>\n<td width=\"320\">Overheat of radiator<\/td>\n<\/tr>\n<tr>\n<td width=\"78\">\n<p align=\"center\">AL-10<\/p>\n<\/td>\n<td width=\"320\">Low voltage of input power.<\/td>\n<\/tr>\n<tr>\n<td width=\"78\">\n<p align=\"center\">AL-11<\/p>\n<\/td>\n<td width=\"320\">Excessive high voltage of DC link<\/td>\n<\/tr>\n<tr>\n<td width=\"78\">\n<p align=\"center\">AL-12<\/p>\n<\/td>\n<td width=\"320\">Abnormal current of DC link<\/td>\n<\/tr>\n<tr>\n<td width=\"78\">\n<p align=\"center\">AL-13<\/p>\n<\/td>\n<td width=\"320\">Defective arithmetic circuit<\/td>\n<\/tr>\n<tr>\n<td width=\"78\">\n<p align=\"center\">AL-14<\/p>\n<\/td>\n<td width=\"320\">Defective ROM<\/td>\n<\/tr>\n<tr>\n<td width=\"78\">\n<p align=\"center\">AL-15<\/p>\n<\/td>\n<td width=\"320\">Defective optional circuit.<\/td>\n<\/tr>\n<tr>\n<td width=\"78\">\n<p align=\"center\">AL-16-23<\/p>\n<\/td>\n<td width=\"320\">Defective arithmetic circuit and peripheral circuit<\/td>\n<\/tr>\n<tr>\n<td width=\"78\">\n<p align=\"center\">No indication<\/p>\n<\/td>\n<td width=\"320\">Defective ROM<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n\n<h2 class=\"wp-block-heading\" id=\"h-dealing-with-fanuc-spindle-alarms\">Dealing with FANUC spindle alarms?<\/h2>\n\n\n\n<p> Let MRO help you troubleshoot and repair your spindle amplifier, with our professional repair services! Or, if you need a replacement FANUC part, we have you covered with our extensive selection of FANUC parts.<\/p>\n\n\n\n<div class=\"btn-wrapper center\"><a href=\"https:\/\/www.mroelectric.com\/repair\/fanuc\" class=\"btn-custom md blue\">Learn More About Our FANUC Repair Services<\/a><\/div>\n\n\n\n<div class=\"btn-wrapper center mb-2\"><a href=\"https:\/\/www.mroelectric.com\/fanuc\/1\" class=\"btn-custom sm blue\">Shop FANUC Replacement Parts<\/a><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Alarm # Led Display Content of FANUC SPINDLE Alarms 8 4 2 1 1 &nbsp; &nbsp; &nbsp; o Motor Overheat 2 &nbsp; &nbsp; o &nbsp; Speed deviates from commanded speed 3 &nbsp; &nbsp; o o Regenerative fault 6 &nbsp; o o &nbsp; Excess Motor Speed Analog 7 &nbsp; o o o Excess Motor Speed Digital [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"","_lmt_disable":"","_exactmetrics_skip_tracking":false,"_exactmetrics_sitenote_active":false,"_exactmetrics_sitenote_note":"","_exactmetrics_sitenote_category":0,"ngg_post_thumbnail":0,"footnotes":""},"categories":[77,12],"tags":[67],"class_list":["post-186","post","type-post","status-publish","format-standard","hentry","category-fanuc","category-troubleshooting-and-repair","tag-alarm-and-fault-codes"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v25.3.1 (Yoast SEO v25.3.1) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Fanuc Spindle Alarms List - Information and Troubleshooting<\/title>\n<meta name=\"description\" content=\"Table and contents listing Fanuc Spindle Alarms to help with troubleshooting tips and tricks. MRO Electric can also supply you with a new FANUC amplfier.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.mroelectric.com\/blog\/fanuc-spindle-alarms\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Fanuc Spindle Alarms for Troubleshooting\" \/>\n<meta property=\"og:description\" content=\"Table and contents listing Fanuc Spindle Alarms to help with troubleshooting tips and tricks. MRO Electric can also supply you with a new FANUC amplfier.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.mroelectric.com\/blog\/fanuc-spindle-alarms\/\" \/>\n<meta property=\"og:site_name\" content=\"MRO Electric Blog\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/mroelectric\/\" \/>\n<meta property=\"article:published_time\" content=\"2015-05-01T13:09:35+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-03-20T17:54:54+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/A06B-6079-H106.jpg\" \/>\n<meta name=\"author\" content=\"Joe Kaminski\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@mroelectric\" \/>\n<meta name=\"twitter:site\" content=\"@mroelectric\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Joe Kaminski\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/fanuc-spindle-alarms\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/fanuc-spindle-alarms\/\"},\"author\":{\"name\":\"Joe Kaminski\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/b993515a2417163a23dfe88597c8d13a\"},\"headline\":\"Fanuc Spindle Alarms for Troubleshooting\",\"datePublished\":\"2015-05-01T13:09:35+00:00\",\"dateModified\":\"2024-03-20T17:54:54+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/fanuc-spindle-alarms\/\"},\"wordCount\":759,\"commentCount\":4,\"publisher\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#organization\"},\"image\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/fanuc-spindle-alarms\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/A06B-6079-H106.jpg\",\"keywords\":[\"Alarms &amp; Faults\"],\"articleSection\":[\"Fanuc\",\"Troubleshooting &amp; Repair\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/www.mroelectric.com\/blog\/fanuc-spindle-alarms\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/fanuc-spindle-alarms\/\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/fanuc-spindle-alarms\/\",\"name\":\"Fanuc Spindle Alarms List - Information and Troubleshooting\",\"isPartOf\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/fanuc-spindle-alarms\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/fanuc-spindle-alarms\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/A06B-6079-H106.jpg\",\"datePublished\":\"2015-05-01T13:09:35+00:00\",\"dateModified\":\"2024-03-20T17:54:54+00:00\",\"description\":\"Table and contents listing Fanuc Spindle Alarms to help with troubleshooting tips and tricks. MRO Electric can also supply you with a new FANUC amplfier.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/fanuc-spindle-alarms\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.mroelectric.com\/blog\/fanuc-spindle-alarms\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/fanuc-spindle-alarms\/#primaryimage\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/A06B-6079-H106.jpg\",\"contentUrl\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/A06B-6079-H106.jpg\",\"width\":217,\"height\":375,\"caption\":\"A06B-6079-H106\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/fanuc-spindle-alarms\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.mroelectric.com\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Fanuc Spindle Alarms for Troubleshooting\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#website\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/\",\"name\":\"MRO Electric Blog\",\"description\":\"Applications of PLCs, CNCs, and more!\",\"publisher\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.mroelectric.com\/blog\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#organization\",\"name\":\"MRO Electric and Supply\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro-logo-new_large2_blue-1.png\",\"contentUrl\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro-logo-new_large2_blue-1.png\",\"width\":430,\"height\":222,\"caption\":\"MRO Electric and Supply\"},\"image\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/mroelectric\/\",\"https:\/\/x.com\/mroelectric\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/b993515a2417163a23dfe88597c8d13a\",\"name\":\"Joe Kaminski\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/fb7c0d641ed541ad912b27609e8079304fc356be7b5b53578b32ad3fa973f506?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/fb7c0d641ed541ad912b27609e8079304fc356be7b5b53578b32ad3fa973f506?s=96&d=mm&r=g\",\"caption\":\"Joe Kaminski\"},\"description\":\"Joe Kaminski is an industrial automation specialist at MRO Electric. He has a background in industrial engineering and supply chain management. Joe has worked in the automation industry for over 10 years providing support to some of the largest companies in the world. For more info, visit www.mroelectric.com.\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/author\/jadmin\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Fanuc Spindle Alarms List - Information and Troubleshooting","description":"Table and contents listing Fanuc Spindle Alarms to help with troubleshooting tips and tricks. MRO Electric can also supply you with a new FANUC amplfier.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.mroelectric.com\/blog\/fanuc-spindle-alarms\/","og_locale":"en_US","og_type":"article","og_title":"Fanuc Spindle Alarms for Troubleshooting","og_description":"Table and contents listing Fanuc Spindle Alarms to help with troubleshooting tips and tricks. MRO Electric can also supply you with a new FANUC amplfier.","og_url":"https:\/\/www.mroelectric.com\/blog\/fanuc-spindle-alarms\/","og_site_name":"MRO Electric Blog","article_publisher":"https:\/\/www.facebook.com\/mroelectric\/","article_published_time":"2015-05-01T13:09:35+00:00","article_modified_time":"2024-03-20T17:54:54+00:00","og_image":[{"url":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/A06B-6079-H106.jpg","type":"","width":"","height":""}],"author":"Joe Kaminski","twitter_card":"summary_large_image","twitter_creator":"@mroelectric","twitter_site":"@mroelectric","twitter_misc":{"Written by":"Joe Kaminski","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.mroelectric.com\/blog\/fanuc-spindle-alarms\/#article","isPartOf":{"@id":"https:\/\/www.mroelectric.com\/blog\/fanuc-spindle-alarms\/"},"author":{"name":"Joe Kaminski","@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/b993515a2417163a23dfe88597c8d13a"},"headline":"Fanuc Spindle Alarms for Troubleshooting","datePublished":"2015-05-01T13:09:35+00:00","dateModified":"2024-03-20T17:54:54+00:00","mainEntityOfPage":{"@id":"https:\/\/www.mroelectric.com\/blog\/fanuc-spindle-alarms\/"},"wordCount":759,"commentCount":4,"publisher":{"@id":"https:\/\/www.mroelectric.com\/blog\/#organization"},"image":{"@id":"https:\/\/www.mroelectric.com\/blog\/fanuc-spindle-alarms\/#primaryimage"},"thumbnailUrl":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/A06B-6079-H106.jpg","keywords":["Alarms &amp; Faults"],"articleSection":["Fanuc","Troubleshooting &amp; Repair"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.mroelectric.com\/blog\/fanuc-spindle-alarms\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.mroelectric.com\/blog\/fanuc-spindle-alarms\/","url":"https:\/\/www.mroelectric.com\/blog\/fanuc-spindle-alarms\/","name":"Fanuc Spindle Alarms List - Information and Troubleshooting","isPartOf":{"@id":"https:\/\/www.mroelectric.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.mroelectric.com\/blog\/fanuc-spindle-alarms\/#primaryimage"},"image":{"@id":"https:\/\/www.mroelectric.com\/blog\/fanuc-spindle-alarms\/#primaryimage"},"thumbnailUrl":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/A06B-6079-H106.jpg","datePublished":"2015-05-01T13:09:35+00:00","dateModified":"2024-03-20T17:54:54+00:00","description":"Table and contents listing Fanuc Spindle Alarms to help with troubleshooting tips and tricks. MRO Electric can also supply you with a new FANUC amplfier.","breadcrumb":{"@id":"https:\/\/www.mroelectric.com\/blog\/fanuc-spindle-alarms\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.mroelectric.com\/blog\/fanuc-spindle-alarms\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mroelectric.com\/blog\/fanuc-spindle-alarms\/#primaryimage","url":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/A06B-6079-H106.jpg","contentUrl":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/A06B-6079-H106.jpg","width":217,"height":375,"caption":"A06B-6079-H106"},{"@type":"BreadcrumbList","@id":"https:\/\/www.mroelectric.com\/blog\/fanuc-spindle-alarms\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.mroelectric.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Fanuc Spindle Alarms for Troubleshooting"}]},{"@type":"WebSite","@id":"https:\/\/www.mroelectric.com\/blog\/#website","url":"https:\/\/www.mroelectric.com\/blog\/","name":"MRO Electric Blog","description":"Applications of PLCs, CNCs, and more!","publisher":{"@id":"https:\/\/www.mroelectric.com\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.mroelectric.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.mroelectric.com\/blog\/#organization","name":"MRO Electric and Supply","url":"https:\/\/www.mroelectric.com\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro-logo-new_large2_blue-1.png","contentUrl":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro-logo-new_large2_blue-1.png","width":430,"height":222,"caption":"MRO Electric and Supply"},"image":{"@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/mroelectric\/","https:\/\/x.com\/mroelectric"]},{"@type":"Person","@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/b993515a2417163a23dfe88597c8d13a","name":"Joe Kaminski","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/fb7c0d641ed541ad912b27609e8079304fc356be7b5b53578b32ad3fa973f506?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/fb7c0d641ed541ad912b27609e8079304fc356be7b5b53578b32ad3fa973f506?s=96&d=mm&r=g","caption":"Joe Kaminski"},"description":"Joe Kaminski is an industrial automation specialist at MRO Electric. He has a background in industrial engineering and supply chain management. Joe has worked in the automation industry for over 10 years providing support to some of the largest companies in the world. For more info, visit www.mroelectric.com.","url":"https:\/\/www.mroelectric.com\/blog\/author\/jadmin\/"}]}},"modified_by":"Joe Kaminski","_links":{"self":[{"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/posts\/186","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/comments?post=186"}],"version-history":[{"count":9,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/posts\/186\/revisions"}],"predecessor-version":[{"id":5849,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/posts\/186\/revisions\/5849"}],"wp:attachment":[{"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/media?parent=186"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/categories?post=186"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/tags?post=186"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}