{"id":206,"date":"2015-05-18T13:59:28","date_gmt":"2015-05-18T13:59:28","guid":{"rendered":"http:\/\/www.mroelectric.com\/blog\/?p=206"},"modified":"2020-03-05T11:38:26","modified_gmt":"2020-03-05T16:38:26","slug":"simodrive-f15-alarm","status":"publish","type":"post","link":"https:\/\/www.mroelectric.com\/blog\/simodrive-f15-alarm\/","title":{"rendered":"Simodrive F15 Alarm Code &#8211; Cause and Solution"},"content":{"rendered":"<p>Recently a customer sent in a <a href=\"https:\/\/www.mroelectric.com\/siemens\/simodrive\/1\">Siemens Simodrive<\/a> for repair when they were getting an F15 Alarm on the unit. The description for this alarm is as follows:<\/p>\n<p>&#8211; F\u201315 Drive converter<br \/>\n&#8211; Overtemperature<br \/>\n\u0002&nbsp;&nbsp;&nbsp;&nbsp; &#8211; Drive converter overloaded<br \/>\n(incorrect motor\/converter assignment, incorrect load duty cycle,<br \/>\nclock cycle frequency too high)<br \/>\n\u0002&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &#8211; Ambient temperature too high<br \/>\n\u0002&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &#8211; Fan in the IM module failed<br \/>\n\u0002&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &#8211; Defective temperature sensor in the IM module<\/p>\n<p>Normally, this <a href=\"https:\/\/www.mroelectric.com\/siemens\/simodrive\/1\">Simodrive<\/a> F15 Alarm is in reference to the fans in the unit failing, which in turn causes an over temperature issue in the unit. This is normally caused by the fans not being cleaned out regularly which causes them to jam, which can then short out other internal boards in the unit. This was the case for the unit the customer sent in, so we took apart the unit, replaced the fans, and replaced several internal boards that had shorted. We would highly recommend routine cleaning of <a href=\"https:\/\/www.mroelectric.com\/siemens\/simodrive\/1\">Simodrive<\/a> fans, especially dirty ones, to prevent drive failure.<\/p>\n<p><strong><a href=\"https:\/\/www.mroelectric.com\/\">MRO Electric and Supply<\/a> supplies and repairs a large number of Siemens Simodrives. To request a quote, please call <a href=\"tel:800-691-8511\">800-691-8511<\/a> or email <a href=\"mailto:sales@mroelectric.com\">sales@mroelectric.com<\/a>.<\/strong><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Recently a customer sent in a Siemens Simodrive for repair when they were getting an F15 Alarm on the unit. The description for this alarm is as follows: &#8211; F\u201315 Drive converter &#8211; Overtemperature \u0002&nbsp;&nbsp;&nbsp;&nbsp; &#8211; Drive converter overloaded (incorrect motor\/converter assignment, incorrect load duty cycle, clock cycle frequency too high) \u0002&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &#8211; Ambient temperature [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"","_lmt_disable":"","_exactmetrics_skip_tracking":false,"_exactmetrics_sitenote_active":false,"_exactmetrics_sitenote_note":"","_exactmetrics_sitenote_category":0,"ngg_post_thumbnail":0,"footnotes":""},"categories":[235,12],"tags":[67,55],"class_list":["post-206","post","type-post","status-publish","format-standard","hentry","category-siemens","category-troubleshooting-and-repair","tag-alarm-and-fault-codes","tag-simodrive"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v25.3.1 (Yoast SEO v25.3.1) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Simodrive F15 Alarm Code - Common Causes and Solutions<\/title>\n<meta name=\"description\" content=\"Causes of the Simodrive F15 Alarm code, along with the solution to keep it from happening to your unit. MRO Electric supplies new and refurbished Simodrives\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.mroelectric.com\/blog\/simodrive-f15-alarm\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Simodrive F15 Alarm Code - Cause and Solution\" \/>\n<meta property=\"og:description\" content=\"Causes of the Simodrive F15 Alarm code, along with the solution to keep it from happening to your unit. MRO Electric supplies new and refurbished Simodrives\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.mroelectric.com\/blog\/simodrive-f15-alarm\/\" \/>\n<meta property=\"og:site_name\" content=\"MRO Electric Blog\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/mroelectric\/\" \/>\n<meta property=\"article:published_time\" content=\"2015-05-18T13:59:28+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-03-05T16:38:26+00:00\" \/>\n<meta name=\"author\" content=\"Joe Kaminski\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@mroelectric\" \/>\n<meta name=\"twitter:site\" content=\"@mroelectric\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Joe Kaminski\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/simodrive-f15-alarm\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/simodrive-f15-alarm\/\"},\"author\":{\"name\":\"Joe Kaminski\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/b993515a2417163a23dfe88597c8d13a\"},\"headline\":\"Simodrive F15 Alarm Code &#8211; Cause and Solution\",\"datePublished\":\"2015-05-18T13:59:28+00:00\",\"dateModified\":\"2020-03-05T16:38:26+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/simodrive-f15-alarm\/\"},\"wordCount\":222,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#organization\"},\"keywords\":[\"Alarms &amp; Faults\",\"Simodrive\"],\"articleSection\":[\"Siemens\",\"Troubleshooting &amp; Repair\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/www.mroelectric.com\/blog\/simodrive-f15-alarm\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/simodrive-f15-alarm\/\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/simodrive-f15-alarm\/\",\"name\":\"Simodrive F15 Alarm Code - Common Causes and Solutions\",\"isPartOf\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#website\"},\"datePublished\":\"2015-05-18T13:59:28+00:00\",\"dateModified\":\"2020-03-05T16:38:26+00:00\",\"description\":\"Causes of the Simodrive F15 Alarm code, along with the solution to keep it from happening to your unit. MRO Electric supplies new and refurbished Simodrives\",\"breadcrumb\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/simodrive-f15-alarm\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.mroelectric.com\/blog\/simodrive-f15-alarm\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/simodrive-f15-alarm\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.mroelectric.com\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Simodrive F15 Alarm Code &#8211; Cause and Solution\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#website\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/\",\"name\":\"MRO Electric Blog\",\"description\":\"Applications of PLCs, CNCs, and more!\",\"publisher\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.mroelectric.com\/blog\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#organization\",\"name\":\"MRO Electric and Supply\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro-logo-new_large2_blue-1.png\",\"contentUrl\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro-logo-new_large2_blue-1.png\",\"width\":430,\"height\":222,\"caption\":\"MRO Electric and Supply\"},\"image\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/mroelectric\/\",\"https:\/\/x.com\/mroelectric\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/b993515a2417163a23dfe88597c8d13a\",\"name\":\"Joe Kaminski\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/fb7c0d641ed541ad912b27609e8079304fc356be7b5b53578b32ad3fa973f506?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/fb7c0d641ed541ad912b27609e8079304fc356be7b5b53578b32ad3fa973f506?s=96&d=mm&r=g\",\"caption\":\"Joe Kaminski\"},\"description\":\"Joe Kaminski is an industrial automation specialist at MRO Electric. He has a background in industrial engineering and supply chain management. Joe has worked in the automation industry for over 10 years providing support to some of the largest companies in the world. For more info, visit www.mroelectric.com.\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/author\/jadmin\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Simodrive F15 Alarm Code - Common Causes and Solutions","description":"Causes of the Simodrive F15 Alarm code, along with the solution to keep it from happening to your unit. MRO Electric supplies new and refurbished Simodrives","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.mroelectric.com\/blog\/simodrive-f15-alarm\/","og_locale":"en_US","og_type":"article","og_title":"Simodrive F15 Alarm Code - Cause and Solution","og_description":"Causes of the Simodrive F15 Alarm code, along with the solution to keep it from happening to your unit. MRO Electric supplies new and refurbished Simodrives","og_url":"https:\/\/www.mroelectric.com\/blog\/simodrive-f15-alarm\/","og_site_name":"MRO Electric Blog","article_publisher":"https:\/\/www.facebook.com\/mroelectric\/","article_published_time":"2015-05-18T13:59:28+00:00","article_modified_time":"2020-03-05T16:38:26+00:00","author":"Joe Kaminski","twitter_card":"summary_large_image","twitter_creator":"@mroelectric","twitter_site":"@mroelectric","twitter_misc":{"Written by":"Joe Kaminski","Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.mroelectric.com\/blog\/simodrive-f15-alarm\/#article","isPartOf":{"@id":"https:\/\/www.mroelectric.com\/blog\/simodrive-f15-alarm\/"},"author":{"name":"Joe Kaminski","@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/b993515a2417163a23dfe88597c8d13a"},"headline":"Simodrive F15 Alarm Code &#8211; Cause and Solution","datePublished":"2015-05-18T13:59:28+00:00","dateModified":"2020-03-05T16:38:26+00:00","mainEntityOfPage":{"@id":"https:\/\/www.mroelectric.com\/blog\/simodrive-f15-alarm\/"},"wordCount":222,"commentCount":0,"publisher":{"@id":"https:\/\/www.mroelectric.com\/blog\/#organization"},"keywords":["Alarms &amp; Faults","Simodrive"],"articleSection":["Siemens","Troubleshooting &amp; Repair"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.mroelectric.com\/blog\/simodrive-f15-alarm\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.mroelectric.com\/blog\/simodrive-f15-alarm\/","url":"https:\/\/www.mroelectric.com\/blog\/simodrive-f15-alarm\/","name":"Simodrive F15 Alarm Code - Common Causes and Solutions","isPartOf":{"@id":"https:\/\/www.mroelectric.com\/blog\/#website"},"datePublished":"2015-05-18T13:59:28+00:00","dateModified":"2020-03-05T16:38:26+00:00","description":"Causes of the Simodrive F15 Alarm code, along with the solution to keep it from happening to your unit. MRO Electric supplies new and refurbished Simodrives","breadcrumb":{"@id":"https:\/\/www.mroelectric.com\/blog\/simodrive-f15-alarm\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.mroelectric.com\/blog\/simodrive-f15-alarm\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.mroelectric.com\/blog\/simodrive-f15-alarm\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.mroelectric.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Simodrive F15 Alarm Code &#8211; Cause and Solution"}]},{"@type":"WebSite","@id":"https:\/\/www.mroelectric.com\/blog\/#website","url":"https:\/\/www.mroelectric.com\/blog\/","name":"MRO Electric Blog","description":"Applications of PLCs, CNCs, and more!","publisher":{"@id":"https:\/\/www.mroelectric.com\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.mroelectric.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.mroelectric.com\/blog\/#organization","name":"MRO Electric and Supply","url":"https:\/\/www.mroelectric.com\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro-logo-new_large2_blue-1.png","contentUrl":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro-logo-new_large2_blue-1.png","width":430,"height":222,"caption":"MRO Electric and Supply"},"image":{"@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/mroelectric\/","https:\/\/x.com\/mroelectric"]},{"@type":"Person","@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/b993515a2417163a23dfe88597c8d13a","name":"Joe Kaminski","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/fb7c0d641ed541ad912b27609e8079304fc356be7b5b53578b32ad3fa973f506?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/fb7c0d641ed541ad912b27609e8079304fc356be7b5b53578b32ad3fa973f506?s=96&d=mm&r=g","caption":"Joe Kaminski"},"description":"Joe Kaminski is an industrial automation specialist at MRO Electric. He has a background in industrial engineering and supply chain management. Joe has worked in the automation industry for over 10 years providing support to some of the largest companies in the world. For more info, visit www.mroelectric.com.","url":"https:\/\/www.mroelectric.com\/blog\/author\/jadmin\/"}]}},"modified_by":"Brian Hughes","_links":{"self":[{"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/posts\/206","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/comments?post=206"}],"version-history":[{"count":7,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/posts\/206\/revisions"}],"predecessor-version":[{"id":4544,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/posts\/206\/revisions\/4544"}],"wp:attachment":[{"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/media?parent=206"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/categories?post=206"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/tags?post=206"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}