{"id":2324,"date":"2017-11-08T09:21:24","date_gmt":"2017-11-08T14:21:24","guid":{"rendered":"https:\/\/www.mroelectric.com\/blog\/?p=2324"},"modified":"2020-03-05T10:58:18","modified_gmt":"2020-03-05T15:58:18","slug":"unidrive-classic-hf-trip-codes","status":"publish","type":"post","link":"https:\/\/www.mroelectric.com\/blog\/unidrive-classic-hf-trip-codes\/","title":{"rendered":"Emerson Industrial Automation: Unidrive Classic HF Trip Codes"},"content":{"rendered":"<h6><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-2336 size-full\" src=\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/ss_mro_blog3_03-1.png\" alt=\"Emerson Industrial Automation: Unidrive Classic HF Trip Codes\" width=\"1556\" height=\"1178\" srcset=\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/ss_mro_blog3_03-1.png 1556w, https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/ss_mro_blog3_03-1-300x227.png 300w, https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/ss_mro_blog3_03-1-768x581.png 768w, https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/ss_mro_blog3_03-1-1024x775.png 1024w\" sizes=\"auto, (max-width: 1556px) 100vw, 1556px\" \/><\/h6>\n<h6><\/h6>\n<h6>This document is pertinent to all Unidrive Classic models<\/h6>\n<h5>MRO Electric and Supply has new and refurbished<a href=\"https:\/\/www.mroelectric.com\/control-techniques\/unidrive\/1\">&nbsp;Control Techniques Unidrives&nbsp;&nbsp;<\/a>available now, along with our other <a href=\"https:\/\/www.mroelectric.com\/control-techniques\/1\">Control Techniques products<\/a>. Contact us about <a href=\"https:\/\/www.mroelectric.com\/repair\">pricing for repairs<\/a>. For more information, please call&nbsp;<a href=\"tel:800-691-8511\">800-691-8511<\/a>&nbsp;or email&nbsp;<a href=\"mailto:sales@mroelectric.com\">sales@mroelectric.com<\/a>.<\/h5>\n<h5>Emerson Industrial Automation: Unidrive Classic HF Trip Codes<\/h5>\n<p style=\"text-align: left;\"><span style=\"color: #0000ff;\"><strong>HF81 Software Error (odd address word)<\/strong><\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignright wp-image-2330\" src=\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/ss_mro_blog3_02.png\" alt=\"Unidrive Fault Code DiagnosticsHF81 HF82 HF83 HF84 HF85 HF86 HF87 HF88 HF89 HF90 HF91 HF92 HF93 HF94 HF95 HF96 HF97 HF98 HF99\" width=\"363\" height=\"455\" srcset=\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/ss_mro_blog3_02.png 474w, https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/ss_mro_blog3_02-239x300.png 239w\" sizes=\"auto, (max-width: 363px) 100vw, 363px\" \/><\/p>\n<p><span style=\"color: #ff0000;\"><strong> HF82 Large Option Module Missing<\/strong><\/span><\/p>\n<p><span style=\"color: #ff0000;\"><strong> HF83 Power Board Code Failure <\/strong><\/span><\/p>\n<p><span style=\"color: #ff0000;\"><strong>HF84 Current Offset Trim Failure <\/strong><\/span><\/p>\n<p><span style=\"color: #0000ff;\"><strong>HF85 A to D failure (ES-CC step) <\/strong><\/span><\/p>\n<p><span style=\"color: #0000ff;\"><strong>HF86 Interrupt Watchdog failure <\/strong><\/span><\/p>\n<p><span style=\"color: #0000ff;\"><strong>HF87 Internal ROM check error <\/strong><\/span><\/p>\n<p><span style=\"color: #ff0000;\"><strong>HF88 Watchdog Failure <\/strong><\/span><\/p>\n<p><span style=\"color: #0000ff;\"><strong>HF89 Unused Interrupts (nmi as source) <\/strong><\/span><\/p>\n<p><span style=\"color: #0000ff;\"><strong>HF90 Stack Overflow <\/strong><\/span><\/p>\n<p><span style=\"color: #0000ff;\"><strong>HF91 Stack Underflow <\/strong><\/span><\/p>\n<p><span style=\"color: #0000ff;\"><strong>HF92 Software Error (undefined op code) <\/strong><\/span><\/p>\n<p><span style=\"color: #0000ff;\"><strong>HF93 Software Error (protection fault) <\/strong><\/span><\/p>\n<p><span style=\"color: #0000ff;\"><strong>HF94 Software Error (odd address word) <\/strong><\/span><\/p>\n<p><span style=\"color: #0000ff;\"><strong>HF95 Software Error (odd address instruction) <\/strong><\/span><\/p>\n<p><span style=\"color: #0000ff;\"><strong>HF96 Software Error (illegal ext bus) <\/strong><\/span><\/p>\n<p><span style=\"color: #0000ff;\"><strong>HF97 Level 1 Noise <\/strong><\/span><\/p>\n<p><span style=\"color: #0000ff;\"><strong>HF98 Interrupt Crash<\/strong><\/span><\/p>\n<p><span style=\"color: #0000ff;\"><strong>HF99 Level 1 Crash<\/strong><\/span><\/p>\n<h4><strong>HF Faults are not recorded in the Drive Historical Fault Log <\/strong><\/h4>\n<h4>All of the above HF trips <span style=\"color: #0000ff;\"><strong>in BLUE<\/strong><\/span> are typically a result of some sort of hardware failure on the UD90A control PCB. This control board is common to all Unidrive Classics.<\/h4>\n<h4><strong>For the HF codes <span style=\"color: #ff0000;\">in RED<\/span> refer to the following page <\/strong><\/h4>\n<p><span style=\"color: #ff0000;\"><strong>HF82 Large option module missing <\/strong><\/span><\/p>\n<p>If one of the <strong>UD7x<\/strong> large option modules is removed, the trip may be expected. There is an issue with either the <strong>large option<\/strong> module or the <strong>UD90A<\/strong> control PCB if this trip occurs at any other time than the case above.<\/p>\n<p><span style=\"color: #ff0000;\"><strong>HF83 Power Board Code Failure<\/strong><\/span><\/p>\n<p>Because the <strong>UD90A<\/strong> control PCB was unable to recognize the power rating of the power PCB it is connected to, this trip occurred.<\/p>\n<p>The trip is likely due to the power PCB in the Drive or a problem with the <strong>UD90A<\/strong> control PCB on Unidrive Sizes 1 to 4 (which includes <strong>UNI1401, UNI1402, UNI1403, UNI1404, UNI1405, UNI2401, UNI2402, UNI2403, UNI3401, UNI3402, UNI3403, UNI3404, UINI3405, UNI4401, UNI4402, UNI4403, and UNI4404<\/strong>).<\/p>\n<p><strong>UD99 PCB or the UD90A PCB<\/strong> cause the trip on a <strong>Unidrive Size 5<\/strong>. The interconnects between the PCBs should also be checked, as they could also cause a trip.<\/p>\n<p><span style=\"color: #ff0000;\"><strong>HF84 Current Offset Trim Failure <\/strong><\/span><\/p>\n<p>Due to an issue with the current feedback on the drive, this trip occurs. The trip is likely due to the <strong>power PCB<\/strong> in the Drive on Unidrive Sizes 1 to 4. An issue with the UD90A control PCB may also cause this trip.<\/p>\n<p>The <strong>UD99 PCB<\/strong> or the <strong>UD90A PCB<\/strong> cause the trip on a Unidrive Size 5, along with the interconnects between the PCBs.<\/p>\n<p>HF88 Watchdog Failure<\/p>\n<p>This trip can result from a faulty <strong>UD7x<\/strong> Co-Processor. With power off, remove Co-Processor and re-apply power.<\/p>\n<p><strong><span style=\"color: #ff0000;\">HF82 Large option module missing <\/span><\/strong><\/p>\n<p>If one of the <strong>UD7x<\/strong> larger option modules is removed while the Drive is powered up, this trip is likely to occur. There is an issue with either the <strong>UD90A<\/strong> control PCB or the<strong> large option<\/strong> module if this trip were to occur at any other time.<\/p>\n<p><strong><span style=\"color: #ff0000;\">HF83 Power Board Code Failure <\/span><\/strong><\/p>\n<p>The <strong>UD90A<\/strong> control PCB was unable to recognize the power rating of the power PCB it is connected to, which is what caused the trip.<\/p>\n<p>The trip is likely due to the power PCB in the Drive on Unidrive Sizes 1 to 4, however, an issue with the <strong>UD90A<\/strong> control PCB is also able to cause this trip.<\/p>\n<p>The trip is caused by the<strong> UD90A PCB<\/strong>, the <strong>UD99 PCB<\/strong>, or the interconnects between the PCBs on a <strong>Unidrive Size 5<\/strong>.<\/p>\n<p><strong><span style=\"color: #ff0000;\">HF84 Current Offset Trim Failure <\/span><\/strong><\/p>\n<p>If there is an issue with the current feedback on the Drive, this trip will occur. The trip is likely due to the power PCB in the Drive, but an issue with the <strong>UD90A<\/strong> control PCB could also result in a trip on Unidrive Sizes 1 to 4.<\/p>\n<p>On a <strong>Unidrive Size 5<\/strong>, the trip is cause by either <strong>UD99 PCB<\/strong> or the <strong>UD90A PCB.<\/strong> The interconnects between the PCBs could also cause this trip and should be checked.<\/p>\n<p>A trip could be caused by either <strong>UD99 PCB, UD90A PCB<\/strong>, or the interconnects between the PCBs on a <strong>Unidrive Size 5<\/strong>.<\/p>\n<p><span style=\"color: #ff0000;\"><strong>HF88 Watchdog Failure<\/strong><\/span><\/p>\n<p>A faulty UD7x Co-Processor and large option module, ( includes <a href=\"https:\/\/www.mroelectric.com\/product\/UD70\">UD70<\/a>, <a href=\"https:\/\/www.mroelectric.com\/product\/UD71\">UD71<\/a>, <a href=\"https:\/\/www.mroelectric.com\/product\/UD73\">UD73<\/a>, <a href=\"https:\/\/www.mroelectric.com\/product\/UD74\">UD74<\/a>, <a href=\"https:\/\/www.mroelectric.com\/product\/UD75\">UD75<\/a>, and <a href=\"https:\/\/www.mroelectric.com\/product\/UD76\">UD76<\/a>) can cause this trip. Remove Co-Processor and re-apply power with power off.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignright wp-image-2329\" src=\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/ss_mro_blog3_01.png\" alt=\"Unidrive Fault Code DiagnosticsHF81 HF82 HF83 HF84 HF85 HF86 HF87 HF88 HF89 HF90 HF91 HF92 HF93 HF94 HF95 HF96 HF97 HF98 HF99\" width=\"350\" height=\"307\" srcset=\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/ss_mro_blog3_01.png 732w, https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/ss_mro_blog3_01-300x263.png 300w\" sizes=\"auto, (max-width: 350px) 100vw, 350px\" \/><\/p>\n","protected":false},"excerpt":{"rendered":"<p>This document is pertinent to all Unidrive Classic models MRO Electric and Supply has new and refurbished&nbsp;Control Techniques Unidrives&nbsp;&nbsp;available now, along with our other Control Techniques products. Contact us about pricing for repairs. For more information, please call&nbsp;800-691-8511&nbsp;or email&nbsp;sales@mroelectric.com. Emerson Industrial Automation: Unidrive Classic HF Trip Codes HF81 Software Error (odd address word) HF82 Large [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"","_lmt_disable":"","_exactmetrics_skip_tracking":false,"_exactmetrics_sitenote_active":false,"_exactmetrics_sitenote_note":"","_exactmetrics_sitenote_category":0,"ngg_post_thumbnail":0,"footnotes":""},"categories":[97,12],"tags":[11,15],"class_list":["post-2324","post","type-post","status-publish","format-standard","hentry","category-control-techniques","category-troubleshooting-and-repair","tag-trip-codes","tag-unidrive"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v25.3.1 (Yoast SEO v25.3.1) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Emerson Industrial Automation: Unidrive Classic HF Trip Codes<\/title>\n<meta name=\"description\" content=\"Unidrive Fault Code DiagnosticsHF81 HF82 HF83 HF84 HF85 HF86 HF87 HF88 HF89 HF90 HF91 HF92 HF93 HF94 HF95 HF96 HF97 HF98 HF99\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.mroelectric.com\/blog\/unidrive-classic-hf-trip-codes\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Emerson Industrial Automation: Unidrive Classic HF Trip Codes\" \/>\n<meta property=\"og:description\" content=\"Unidrive Fault Code DiagnosticsHF81 HF82 HF83 HF84 HF85 HF86 HF87 HF88 HF89 HF90 HF91 HF92 HF93 HF94 HF95 HF96 HF97 HF98 HF99\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.mroelectric.com\/blog\/unidrive-classic-hf-trip-codes\/\" \/>\n<meta property=\"og:site_name\" content=\"MRO Electric Blog\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/mroelectric\/\" \/>\n<meta property=\"article:published_time\" content=\"2017-11-08T14:21:24+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-03-05T15:58:18+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/ss_mro_blog3_03-1.png\" \/>\n<meta name=\"author\" content=\"Joe Kaminski\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@mroelectric\" \/>\n<meta name=\"twitter:site\" content=\"@mroelectric\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Joe Kaminski\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/unidrive-classic-hf-trip-codes\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/unidrive-classic-hf-trip-codes\/\"},\"author\":{\"name\":\"Joe Kaminski\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/b993515a2417163a23dfe88597c8d13a\"},\"headline\":\"Emerson Industrial Automation: Unidrive Classic HF Trip Codes\",\"datePublished\":\"2017-11-08T14:21:24+00:00\",\"dateModified\":\"2020-03-05T15:58:18+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/unidrive-classic-hf-trip-codes\/\"},\"wordCount\":734,\"commentCount\":1,\"publisher\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#organization\"},\"image\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/unidrive-classic-hf-trip-codes\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/ss_mro_blog3_03-1.png\",\"keywords\":[\"Trip Codes\",\"Unidrive\"],\"articleSection\":[\"Control Techniques\",\"Troubleshooting &amp; Repair\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/www.mroelectric.com\/blog\/unidrive-classic-hf-trip-codes\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/unidrive-classic-hf-trip-codes\/\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/unidrive-classic-hf-trip-codes\/\",\"name\":\"Emerson Industrial Automation: Unidrive Classic HF Trip Codes\",\"isPartOf\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/unidrive-classic-hf-trip-codes\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/unidrive-classic-hf-trip-codes\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/ss_mro_blog3_03-1.png\",\"datePublished\":\"2017-11-08T14:21:24+00:00\",\"dateModified\":\"2020-03-05T15:58:18+00:00\",\"description\":\"Unidrive Fault Code DiagnosticsHF81 HF82 HF83 HF84 HF85 HF86 HF87 HF88 HF89 HF90 HF91 HF92 HF93 HF94 HF95 HF96 HF97 HF98 HF99\",\"breadcrumb\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/unidrive-classic-hf-trip-codes\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.mroelectric.com\/blog\/unidrive-classic-hf-trip-codes\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/unidrive-classic-hf-trip-codes\/#primaryimage\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/ss_mro_blog3_03-1.png\",\"contentUrl\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/ss_mro_blog3_03-1.png\",\"width\":1556,\"height\":1178,\"caption\":\"Control Techniques Unidrive\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/unidrive-classic-hf-trip-codes\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.mroelectric.com\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Emerson Industrial Automation: Unidrive Classic HF Trip Codes\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#website\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/\",\"name\":\"MRO Electric Blog\",\"description\":\"Applications of PLCs, CNCs, and more!\",\"publisher\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.mroelectric.com\/blog\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#organization\",\"name\":\"MRO Electric and Supply\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro-logo-new_large2_blue-1.png\",\"contentUrl\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro-logo-new_large2_blue-1.png\",\"width\":430,\"height\":222,\"caption\":\"MRO Electric and Supply\"},\"image\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/mroelectric\/\",\"https:\/\/x.com\/mroelectric\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/b993515a2417163a23dfe88597c8d13a\",\"name\":\"Joe Kaminski\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/fb7c0d641ed541ad912b27609e8079304fc356be7b5b53578b32ad3fa973f506?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/fb7c0d641ed541ad912b27609e8079304fc356be7b5b53578b32ad3fa973f506?s=96&d=mm&r=g\",\"caption\":\"Joe Kaminski\"},\"description\":\"Joe Kaminski is an industrial automation specialist at MRO Electric. He has a background in industrial engineering and supply chain management. Joe has worked in the automation industry for over 10 years providing support to some of the largest companies in the world. For more info, visit www.mroelectric.com.\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/author\/jadmin\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Emerson Industrial Automation: Unidrive Classic HF Trip Codes","description":"Unidrive Fault Code DiagnosticsHF81 HF82 HF83 HF84 HF85 HF86 HF87 HF88 HF89 HF90 HF91 HF92 HF93 HF94 HF95 HF96 HF97 HF98 HF99","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.mroelectric.com\/blog\/unidrive-classic-hf-trip-codes\/","og_locale":"en_US","og_type":"article","og_title":"Emerson Industrial Automation: Unidrive Classic HF Trip Codes","og_description":"Unidrive Fault Code DiagnosticsHF81 HF82 HF83 HF84 HF85 HF86 HF87 HF88 HF89 HF90 HF91 HF92 HF93 HF94 HF95 HF96 HF97 HF98 HF99","og_url":"https:\/\/www.mroelectric.com\/blog\/unidrive-classic-hf-trip-codes\/","og_site_name":"MRO Electric Blog","article_publisher":"https:\/\/www.facebook.com\/mroelectric\/","article_published_time":"2017-11-08T14:21:24+00:00","article_modified_time":"2020-03-05T15:58:18+00:00","og_image":[{"url":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/ss_mro_blog3_03-1.png","type":"","width":"","height":""}],"author":"Joe Kaminski","twitter_card":"summary_large_image","twitter_creator":"@mroelectric","twitter_site":"@mroelectric","twitter_misc":{"Written by":"Joe Kaminski","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.mroelectric.com\/blog\/unidrive-classic-hf-trip-codes\/#article","isPartOf":{"@id":"https:\/\/www.mroelectric.com\/blog\/unidrive-classic-hf-trip-codes\/"},"author":{"name":"Joe Kaminski","@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/b993515a2417163a23dfe88597c8d13a"},"headline":"Emerson Industrial Automation: Unidrive Classic HF Trip Codes","datePublished":"2017-11-08T14:21:24+00:00","dateModified":"2020-03-05T15:58:18+00:00","mainEntityOfPage":{"@id":"https:\/\/www.mroelectric.com\/blog\/unidrive-classic-hf-trip-codes\/"},"wordCount":734,"commentCount":1,"publisher":{"@id":"https:\/\/www.mroelectric.com\/blog\/#organization"},"image":{"@id":"https:\/\/www.mroelectric.com\/blog\/unidrive-classic-hf-trip-codes\/#primaryimage"},"thumbnailUrl":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/ss_mro_blog3_03-1.png","keywords":["Trip Codes","Unidrive"],"articleSection":["Control Techniques","Troubleshooting &amp; Repair"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.mroelectric.com\/blog\/unidrive-classic-hf-trip-codes\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.mroelectric.com\/blog\/unidrive-classic-hf-trip-codes\/","url":"https:\/\/www.mroelectric.com\/blog\/unidrive-classic-hf-trip-codes\/","name":"Emerson Industrial Automation: Unidrive Classic HF Trip Codes","isPartOf":{"@id":"https:\/\/www.mroelectric.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.mroelectric.com\/blog\/unidrive-classic-hf-trip-codes\/#primaryimage"},"image":{"@id":"https:\/\/www.mroelectric.com\/blog\/unidrive-classic-hf-trip-codes\/#primaryimage"},"thumbnailUrl":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/ss_mro_blog3_03-1.png","datePublished":"2017-11-08T14:21:24+00:00","dateModified":"2020-03-05T15:58:18+00:00","description":"Unidrive Fault Code DiagnosticsHF81 HF82 HF83 HF84 HF85 HF86 HF87 HF88 HF89 HF90 HF91 HF92 HF93 HF94 HF95 HF96 HF97 HF98 HF99","breadcrumb":{"@id":"https:\/\/www.mroelectric.com\/blog\/unidrive-classic-hf-trip-codes\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.mroelectric.com\/blog\/unidrive-classic-hf-trip-codes\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mroelectric.com\/blog\/unidrive-classic-hf-trip-codes\/#primaryimage","url":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/ss_mro_blog3_03-1.png","contentUrl":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/ss_mro_blog3_03-1.png","width":1556,"height":1178,"caption":"Control Techniques Unidrive"},{"@type":"BreadcrumbList","@id":"https:\/\/www.mroelectric.com\/blog\/unidrive-classic-hf-trip-codes\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.mroelectric.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Emerson Industrial Automation: Unidrive Classic HF Trip Codes"}]},{"@type":"WebSite","@id":"https:\/\/www.mroelectric.com\/blog\/#website","url":"https:\/\/www.mroelectric.com\/blog\/","name":"MRO Electric Blog","description":"Applications of PLCs, CNCs, and more!","publisher":{"@id":"https:\/\/www.mroelectric.com\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.mroelectric.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.mroelectric.com\/blog\/#organization","name":"MRO Electric and Supply","url":"https:\/\/www.mroelectric.com\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro-logo-new_large2_blue-1.png","contentUrl":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro-logo-new_large2_blue-1.png","width":430,"height":222,"caption":"MRO Electric and Supply"},"image":{"@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/mroelectric\/","https:\/\/x.com\/mroelectric"]},{"@type":"Person","@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/b993515a2417163a23dfe88597c8d13a","name":"Joe Kaminski","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/fb7c0d641ed541ad912b27609e8079304fc356be7b5b53578b32ad3fa973f506?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/fb7c0d641ed541ad912b27609e8079304fc356be7b5b53578b32ad3fa973f506?s=96&d=mm&r=g","caption":"Joe Kaminski"},"description":"Joe Kaminski is an industrial automation specialist at MRO Electric. He has a background in industrial engineering and supply chain management. Joe has worked in the automation industry for over 10 years providing support to some of the largest companies in the world. For more info, visit www.mroelectric.com.","url":"https:\/\/www.mroelectric.com\/blog\/author\/jadmin\/"}]}},"modified_by":"Brian Hughes","_links":{"self":[{"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/posts\/2324","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/comments?post=2324"}],"version-history":[{"count":11,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/posts\/2324\/revisions"}],"predecessor-version":[{"id":4475,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/posts\/2324\/revisions\/4475"}],"wp:attachment":[{"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/media?parent=2324"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/categories?post=2324"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/tags?post=2324"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}