{"id":2737,"date":"2018-03-07T17:30:20","date_gmt":"2018-03-07T22:30:20","guid":{"rendered":"https:\/\/www.mroelectric.com\/blog\/?p=2737"},"modified":"2024-02-14T11:28:07","modified_gmt":"2024-02-14T16:28:07","slug":"kuka-error-codes","status":"publish","type":"post","link":"https:\/\/www.mroelectric.com\/blog\/kuka-error-codes\/","title":{"rendered":"KUKA Error Codes"},"content":{"rendered":"<p><b>&nbsp;<\/b><a href=\"https:\/\/www.mroelectric.com\/kuka\/1\"><span style=\"font-weight: 400;\">KUKA robotics<\/span><\/a><span style=\"font-weight: 400;\"> offers a broad range of <\/span><a href=\"https:\/\/www.mroelectric.com\/kuka\/1\"><span style=\"font-weight: 400;\">robotics controllers<\/span><\/a><span style=\"font-weight: 400;\"> and other robotics parts for a variety of industries including CNC machining, surface processing, loading usage, and much more. One common challenge with operating robotics controllers is understanding what the error codes mean, that they display when they encounter an issue. Listed below are common KUKA error messages that you may encounter while troubleshooting issues with KUKA controllers. These codes are applicable to all KUKA controllers, including the KRC1, KRC2, KRC3, and the KRC4.<\/span><\/p>\n<h2><span style=\"font-weight: 400;\">Common KUKA KRC1, KRC2, KRC3, and KRC4 Error Codes<\/span><\/h2>\n<h3><strong>Error Code 14 &#8211;&nbsp;SOFTPLC: @P1@<\/strong><\/h3>\n<h3><strong>Error Code 284 &#8211;&nbsp;Accu&#8211;voltage at &lt;kps number&gt; below &lt;voltage level&gt; during last buffering<\/strong><\/h3>\n<ul>\n<li>Cause\n<ul>\n<li>The accu voltage was too low at the last switch off to buffer the<br>shutdown.<\/li>\n<li>The accu is not charged correctly anymore.<\/li>\n<li>The accu is too old or broken.<\/li>\n<\/ul>\n<\/li>\n<li>Effect\n<ul>\n<li>Eventually loss of reference.<\/li>\n<li>Cold boot.<\/li>\n<li>Active commands inhibited<\/li>\n<\/ul>\n<\/li>\n<li>Remedy\n<ul>\n<li>Exchange accu.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h3>Error Code 310 &#8211;&nbsp;Safety Circuit for drives not ready<\/h3>\n<ul>\n<li>Cause\n<ul>\n<li>Safety circuit is telling drives not to move.<\/li>\n<li>Faulty X11<\/li>\n<li>Faulty ESC board<\/li>\n<li>Faulty KPS 600<\/li>\n<\/ul>\n<\/li>\n<li>Remedy\n<ul>\n<li>Check ESC monitor and other messages to narrow down the root cause with the safety circuit<\/li>\n<li>Replace faulty components<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h3>Error Code 364 &#8211;&nbsp;Unknown operation mode<\/h3>\n<ul>\n<li>Possible Cause\n<ul>\n<li>Faulty KPS 600 Drive<\/li>\n<\/ul>\n<\/li>\n<li>Remedy\n<ul>\n<li>Replace KPS 600<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h3>Error Code 420 &#8211;&nbsp;Local protective stop (QE)<\/h3>\n<ul>\n<li style=\"list-style-type: none;\">\n<ul>\n<li>Possible Cause\n<ul>\n<li>Faulty KPS600 Drive<\/li>\n<\/ul>\n<\/li>\n<li>Remedy\n<ul>\n<li>Replace KPS600<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h3>Error Code 1033 &#8211;&nbsp;ERROR ON READING, DRIVER: ** **<\/h3>\n<h3>Error Code 1034 &#8211;&nbsp;ERROR ON WRITING, DRIVER: ** **<\/h3>\n<h3>Error Code 1133 &#8211;&nbsp;GEAR TORQUE EXCEEDED AXIS<\/h3>\n<ul>\n<li>Cause\n<ul>\n<li>The calculated gear torque is larger than the maximum permissible gear torque.<\/li>\n<\/ul>\n<\/li>\n<li>Monitor\n<ul>\n<li>Cyclic in interpolation cycle.<\/li>\n<\/ul>\n<\/li>\n<li>Effect\n<ul>\n<li>Motion and program are stopped.<\/li>\n<\/ul>\n<\/li>\n<li>Remedy\n<ul>\n<li>Reteach points.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h3>Error Code 1239 &#8211;&nbsp;ACKN. SYNCHRONISATION ERROR DRIVE<\/h3>\n<h3>Error Code 1376 &#8211;&nbsp;ACTIVE COMMANDS INHIBITED<\/h3>\n<ul>\n<li>Cause\n<ul>\n<li>A message which causes the active commands to be inhibited has been set.<\/li>\n<\/ul>\n<\/li>\n<li>Monitor\n<ul>\n<li>In command processing.<\/li>\n<\/ul>\n<\/li>\n<li>Effect\n<ul>\n<li>Command is not executed.<\/li>\n<\/ul>\n<\/li>\n<li>Remedy\n<ul>\n<li>Acknowledge active messages in the message window.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h3>Error Code 2029 &#8211;&nbsp;SYNTAX ERROR IN KUKA MODULE<\/h3>\n<h3>Error Code 2135 &#8211;&nbsp;NAME NOT DECLARED AS SUBROUTINE<\/h3>\n<h3>Error Code 6502 &#8211;&nbsp;Error during reading INI file init\/iosys.ini 1<\/h3>\n<ul>\n<li>Remedy\n<ul>\n<li>Check iosys.ini file<\/li>\n<li>Ensure correct DeviceNET driver is installed<\/li>\n<li>Check data cable between robot \/ cabinet<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h3>Error Code 10053<\/h3>\n<ul>\n<li>Remedy\n<ul>\n<li>Check fan to ensure it isn&#8217;t vibrating. This could be causing the Mfc card to move into the motherboard&#8217;s slot.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p>To find more info about KUKA error codes, view KUKA&#8217;s manual below.<\/p>\n<p><a href=\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/KUKA.pdf\">View the KUKA Manual<\/a><\/p>\n<p><span style=\"font-weight: 400;\">MRO Electric carries replacement KUKA Robotics parts such as <\/span><a href=\"https:\/\/www.mroelectric.com\/kuka\/robotics\/teach-pendants\/1\"><span style=\"font-weight: 400;\">teach pendants<\/span><\/a><span style=\"font-weight: 400;\">, <\/span><a href=\"https:\/\/www.mroelectric.com\/kuka\/robotics\/ac-drives\/1\"><span style=\"font-weight: 400;\">drives<\/span><\/a><span style=\"font-weight: 400;\">, <\/span><a href=\"https:\/\/www.mroelectric.com\/kuka\/robotics\/ac-motors\/1\"><span style=\"font-weight: 400;\">motors<\/span><\/a><span style=\"font-weight: 400;\">, and more. To request a quote, please call 800-691-8511 or email <\/span><a href=\"mailto:sales@mroelectric.com\"><span style=\"font-weight: 400;\">sales@mroelectric.com<\/span><\/a><span style=\"font-weight: 400;\">.<\/span><\/p>\n\n\n<h2 class=\"wp-block-heading\" id=\"h-troubleshooting-error-codes-on-your-kuka-controller\">Troubleshooting error codes on your KUKA controller?<\/h2>\n\n\n\n<p>We can help you resolve issues with your KUKA controllers. Whether you&#8217;re looking to repair your old controller or purchase a new one, we&#8217;re dedicated to keeping your automation systems running at their best!<\/p>\n\n\n\n<div class=\"btn-wrapper center\"><a href=\"https:\/\/www.mroelectric.com\/repair\" class=\"btn-custom md blue\">Learn More About Our Repair Services<\/a><\/div>\n\n\n\n<div class=\"btn-wrapper center mb-2\"><a href=\"https:\/\/www.mroelectric.com\/kuka\/controllers\/1\" class=\"btn-custom sm blue\">Shop Replacement KUKA Controllers<\/a><\/div>\n","protected":false},"excerpt":{"rendered":"<p>&nbsp;KUKA robotics offers a broad range of robotics controllers and other robotics parts for a variety of industries including CNC machining, surface processing, loading usage, and much more. One common challenge with operating robotics controllers is understanding what the error codes mean, that they display when they encounter an issue. Listed below are common KUKA [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":2739,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"","_lmt_disable":"","_exactmetrics_skip_tracking":false,"_exactmetrics_sitenote_active":false,"_exactmetrics_sitenote_note":"","_exactmetrics_sitenote_category":0,"ngg_post_thumbnail":0,"footnotes":""},"categories":[499,12],"tags":[67],"class_list":["post-2737","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-kuka","category-troubleshooting-and-repair","tag-alarm-and-fault-codes"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v25.3.1 (Yoast SEO v25.3.1) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>KUKA Error Code List | Common KUKA Robot Errors from MRO Electric<\/title>\n<meta name=\"description\" content=\"The list below contains common KUKA controller error codes. These codes are applicable to all KUKA controllers, including the KRC1, KRC2, KRC3, and KRC4.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.mroelectric.com\/blog\/kuka-error-codes\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"KUKA Error Codes\" \/>\n<meta property=\"og:description\" content=\"The list below contains common KUKA controller error codes. These codes are applicable to all KUKA controllers, including the KRC1, KRC2, KRC3, and KRC4.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.mroelectric.com\/blog\/kuka-error-codes\/\" \/>\n<meta property=\"og:site_name\" content=\"MRO Electric Blog\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/mroelectric\/\" \/>\n<meta property=\"article:published_time\" content=\"2018-03-07T22:30:20+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-02-14T16:28:07+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/Steuerungen_KR_C4.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"3200\" \/>\n\t<meta property=\"og:image:height\" content=\"1800\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Joe Kaminski\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@mroelectric\" \/>\n<meta name=\"twitter:site\" content=\"@mroelectric\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Joe Kaminski\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/kuka-error-codes\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/kuka-error-codes\/\"},\"author\":{\"name\":\"Joe Kaminski\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/b993515a2417163a23dfe88597c8d13a\"},\"headline\":\"KUKA Error Codes\",\"datePublished\":\"2018-03-07T22:30:20+00:00\",\"dateModified\":\"2024-02-14T16:28:07+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/kuka-error-codes\/\"},\"wordCount\":506,\"commentCount\":5,\"publisher\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#organization\"},\"image\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/kuka-error-codes\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/Steuerungen_KR_C4.jpg\",\"keywords\":[\"Alarms &amp; Faults\"],\"articleSection\":[\"KUKA\",\"Troubleshooting &amp; Repair\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/www.mroelectric.com\/blog\/kuka-error-codes\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/kuka-error-codes\/\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/kuka-error-codes\/\",\"name\":\"KUKA Error Code List | Common KUKA Robot Errors from MRO Electric\",\"isPartOf\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/kuka-error-codes\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/kuka-error-codes\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/Steuerungen_KR_C4.jpg\",\"datePublished\":\"2018-03-07T22:30:20+00:00\",\"dateModified\":\"2024-02-14T16:28:07+00:00\",\"description\":\"The list below contains common KUKA controller error codes. These codes are applicable to all KUKA controllers, including the KRC1, KRC2, KRC3, and KRC4.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/kuka-error-codes\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.mroelectric.com\/blog\/kuka-error-codes\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/kuka-error-codes\/#primaryimage\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/Steuerungen_KR_C4.jpg\",\"contentUrl\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/Steuerungen_KR_C4.jpg\",\"width\":3200,\"height\":1800,\"caption\":\"KUKA Controllers lineup\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/kuka-error-codes\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.mroelectric.com\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"KUKA Error Codes\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#website\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/\",\"name\":\"MRO Electric Blog\",\"description\":\"Applications of PLCs, CNCs, and more!\",\"publisher\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.mroelectric.com\/blog\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#organization\",\"name\":\"MRO Electric and Supply\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro-logo-new_large2_blue-1.png\",\"contentUrl\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro-logo-new_large2_blue-1.png\",\"width\":430,\"height\":222,\"caption\":\"MRO Electric and Supply\"},\"image\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/mroelectric\/\",\"https:\/\/x.com\/mroelectric\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/b993515a2417163a23dfe88597c8d13a\",\"name\":\"Joe Kaminski\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/fb7c0d641ed541ad912b27609e8079304fc356be7b5b53578b32ad3fa973f506?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/fb7c0d641ed541ad912b27609e8079304fc356be7b5b53578b32ad3fa973f506?s=96&d=mm&r=g\",\"caption\":\"Joe Kaminski\"},\"description\":\"Joe Kaminski is an industrial automation specialist at MRO Electric. He has a background in industrial engineering and supply chain management. Joe has worked in the automation industry for over 10 years providing support to some of the largest companies in the world. For more info, visit www.mroelectric.com.\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/author\/jadmin\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"KUKA Error Code List | Common KUKA Robot Errors from MRO Electric","description":"The list below contains common KUKA controller error codes. These codes are applicable to all KUKA controllers, including the KRC1, KRC2, KRC3, and KRC4.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.mroelectric.com\/blog\/kuka-error-codes\/","og_locale":"en_US","og_type":"article","og_title":"KUKA Error Codes","og_description":"The list below contains common KUKA controller error codes. These codes are applicable to all KUKA controllers, including the KRC1, KRC2, KRC3, and KRC4.","og_url":"https:\/\/www.mroelectric.com\/blog\/kuka-error-codes\/","og_site_name":"MRO Electric Blog","article_publisher":"https:\/\/www.facebook.com\/mroelectric\/","article_published_time":"2018-03-07T22:30:20+00:00","article_modified_time":"2024-02-14T16:28:07+00:00","og_image":[{"width":3200,"height":1800,"url":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/Steuerungen_KR_C4.jpg","type":"image\/jpeg"}],"author":"Joe Kaminski","twitter_card":"summary_large_image","twitter_creator":"@mroelectric","twitter_site":"@mroelectric","twitter_misc":{"Written by":"Joe Kaminski","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.mroelectric.com\/blog\/kuka-error-codes\/#article","isPartOf":{"@id":"https:\/\/www.mroelectric.com\/blog\/kuka-error-codes\/"},"author":{"name":"Joe Kaminski","@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/b993515a2417163a23dfe88597c8d13a"},"headline":"KUKA Error Codes","datePublished":"2018-03-07T22:30:20+00:00","dateModified":"2024-02-14T16:28:07+00:00","mainEntityOfPage":{"@id":"https:\/\/www.mroelectric.com\/blog\/kuka-error-codes\/"},"wordCount":506,"commentCount":5,"publisher":{"@id":"https:\/\/www.mroelectric.com\/blog\/#organization"},"image":{"@id":"https:\/\/www.mroelectric.com\/blog\/kuka-error-codes\/#primaryimage"},"thumbnailUrl":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/Steuerungen_KR_C4.jpg","keywords":["Alarms &amp; Faults"],"articleSection":["KUKA","Troubleshooting &amp; Repair"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.mroelectric.com\/blog\/kuka-error-codes\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.mroelectric.com\/blog\/kuka-error-codes\/","url":"https:\/\/www.mroelectric.com\/blog\/kuka-error-codes\/","name":"KUKA Error Code List | Common KUKA Robot Errors from MRO Electric","isPartOf":{"@id":"https:\/\/www.mroelectric.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.mroelectric.com\/blog\/kuka-error-codes\/#primaryimage"},"image":{"@id":"https:\/\/www.mroelectric.com\/blog\/kuka-error-codes\/#primaryimage"},"thumbnailUrl":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/Steuerungen_KR_C4.jpg","datePublished":"2018-03-07T22:30:20+00:00","dateModified":"2024-02-14T16:28:07+00:00","description":"The list below contains common KUKA controller error codes. These codes are applicable to all KUKA controllers, including the KRC1, KRC2, KRC3, and KRC4.","breadcrumb":{"@id":"https:\/\/www.mroelectric.com\/blog\/kuka-error-codes\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.mroelectric.com\/blog\/kuka-error-codes\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mroelectric.com\/blog\/kuka-error-codes\/#primaryimage","url":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/Steuerungen_KR_C4.jpg","contentUrl":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/Steuerungen_KR_C4.jpg","width":3200,"height":1800,"caption":"KUKA Controllers lineup"},{"@type":"BreadcrumbList","@id":"https:\/\/www.mroelectric.com\/blog\/kuka-error-codes\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.mroelectric.com\/blog\/"},{"@type":"ListItem","position":2,"name":"KUKA Error Codes"}]},{"@type":"WebSite","@id":"https:\/\/www.mroelectric.com\/blog\/#website","url":"https:\/\/www.mroelectric.com\/blog\/","name":"MRO Electric Blog","description":"Applications of PLCs, CNCs, and more!","publisher":{"@id":"https:\/\/www.mroelectric.com\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.mroelectric.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.mroelectric.com\/blog\/#organization","name":"MRO Electric and Supply","url":"https:\/\/www.mroelectric.com\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro-logo-new_large2_blue-1.png","contentUrl":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro-logo-new_large2_blue-1.png","width":430,"height":222,"caption":"MRO Electric and Supply"},"image":{"@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/mroelectric\/","https:\/\/x.com\/mroelectric"]},{"@type":"Person","@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/b993515a2417163a23dfe88597c8d13a","name":"Joe Kaminski","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/fb7c0d641ed541ad912b27609e8079304fc356be7b5b53578b32ad3fa973f506?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/fb7c0d641ed541ad912b27609e8079304fc356be7b5b53578b32ad3fa973f506?s=96&d=mm&r=g","caption":"Joe Kaminski"},"description":"Joe Kaminski is an industrial automation specialist at MRO Electric. He has a background in industrial engineering and supply chain management. Joe has worked in the automation industry for over 10 years providing support to some of the largest companies in the world. For more info, visit www.mroelectric.com.","url":"https:\/\/www.mroelectric.com\/blog\/author\/jadmin\/"}]}},"modified_by":"Joe Kaminski","_links":{"self":[{"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/posts\/2737","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/comments?post=2737"}],"version-history":[{"count":9,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/posts\/2737\/revisions"}],"predecessor-version":[{"id":5794,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/posts\/2737\/revisions\/5794"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/media\/2739"}],"wp:attachment":[{"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/media?parent=2737"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/categories?post=2737"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/tags?post=2737"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}