{"id":3061,"date":"2018-03-27T12:57:56","date_gmt":"2018-03-27T16:57:56","guid":{"rendered":"https:\/\/www.mroelectric.com\/blog\/?p=3061"},"modified":"2021-09-27T08:40:29","modified_gmt":"2021-09-27T12:40:29","slug":"diagnosing-your-fanuc-current-alarm","status":"publish","type":"post","link":"https:\/\/www.mroelectric.com\/blog\/diagnosing-your-fanuc-current-alarm\/","title":{"rendered":"Diagnosing your FANUC Current Alarm"},"content":{"rendered":"<p>If you are getting a high current alarm on <a href=\"https:\/\/www.mroelectric.com\/fanuc\/automation\/ac-motors\/1\">your FANUC motor<\/a>, it is going to be caused by either the motor itself, the drive, or a cable. To begin the process of figuring out which alarm you are receiving you must disconnect the leads from the motor. Try powering it up and look to see if the alarm LED is lit. Fanuc alarms include the HC LED, alarm 8\/9\/A\/B for <a href=\"https:\/\/www.mroelectric.com\/fanuc\/automation\/servo-amplifiers\/1\">Servo motors<\/a>, and alarm 12 for <a href=\"https:\/\/www.mroelectric.com\/fanuc\/automation\/spindle-amplifiers\/1\">Spindle motors<\/a>.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-4006 aligncenter\" src=\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/fanucservoamps-1-300x239.jpg\" alt=\"\" width=\"300\" height=\"239\" srcset=\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/fanucservoamps-1-300x239.jpg 300w, https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/fanucservoamps-1.jpg 375w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/p>\n<ul>\n<li>If you no longer are seeing an alarm, the motor is most likely bad.<\/li>\n<li>If you have powered the motor and are receiving the alarm, the issue is most likely with the drive.<\/li>\n<\/ul>\n<p>Because you have disconnected the leads from the motor, you are able to use an ohm meter\/megger to monitor the power levels of the cable and motor, and make sure they are working as intended. Using a megger will help you decide if your motor is grounded correctly where an ohm reader will let you know if your motor has shorted.<\/p>\n<p>Using your ohm meter check for shorts both leg-to-leg and leg-to-ground on each of the legs. The leg-to-leg readings should be consistently low between every leg while the leg-to-ground readings will stay open. The megger is used to check between the leg and ground to see if the problem could be with the terminal box on the motor or any cables connected to it.<\/p>\n<p>Sometimes you may not have the necessary equipment to make a diagnosis on your motor or to <a href=\"https:\/\/www.mroelectric.com\/blog\/fanuc-troubleshooting-faqs\/\">troubleshoot<\/a>, but we do. MRO Electric and Supply offers <a href=\"https:\/\/www.mroelectric.com\/repair\">high quality repair services<\/a> on all motors so you don&#8217;t have to worry about it. Check out our website to see all available brands and parts we can service for you.<\/p>\n<p><strong>MRO Electric and Supply\u00a0has new and refurbished\u00a0<a href=\"https:\/\/www.mroelectric.com\/fanuc\/1\">FANUC CNC<\/a>\u00a0parts available. We also offer repair pricing. For more information, please call\u00a0<a href=\"tel:800-691-8511\">800-691-8511<\/a>\u00a0or email\u00a0<a href=\"mailto:sales@mroelectric.com\">sales@mroelectric.com<\/a>.<\/strong><\/p>\n","protected":false},"excerpt":{"rendered":"<p>If you are getting a high current alarm on your FANUC motor, it is going to be caused by either the motor itself, the drive, or a cable. To begin the process of figuring out which alarm you are receiving you must disconnect the leads from the motor. Try powering it up and look to [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"","_lmt_disable":"","_exactmetrics_skip_tracking":false,"_exactmetrics_sitenote_active":false,"_exactmetrics_sitenote_note":"","_exactmetrics_sitenote_category":0,"ngg_post_thumbnail":0,"footnotes":""},"categories":[77,12],"tags":[67,85],"class_list":["post-3061","post","type-post","status-publish","format-standard","hentry","category-fanuc","category-troubleshooting-and-repair","tag-alarm-and-fault-codes","tag-motors-and-drives"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v25.3.1 (Yoast SEO v25.3.1) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Diagnosing your HC FANUC Alarms | MRO Electric and Supply Blog<\/title>\n<meta name=\"description\" content=\"Figure out your High Current Fanuc Alarms here. MRO Electric and Supply has everything you need from Control Techniques, Siemens, Schneider Modicon, Yaskawa, etc. Visit our blog for information about products including pricing, specifications, and troubleshooting.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.mroelectric.com\/blog\/diagnosing-your-fanuc-current-alarm\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Diagnosing your FANUC Current Alarm\" \/>\n<meta property=\"og:description\" content=\"Figure out your High Current Fanuc Alarms here. MRO Electric and Supply has everything you need from Control Techniques, Siemens, Schneider Modicon, Yaskawa, etc. Visit our blog for information about products including pricing, specifications, and troubleshooting.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.mroelectric.com\/blog\/diagnosing-your-fanuc-current-alarm\/\" \/>\n<meta property=\"og:site_name\" content=\"MRO Electric Blog\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/mroelectric\/\" \/>\n<meta property=\"article:published_time\" content=\"2018-03-27T16:57:56+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2021-09-27T12:40:29+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/fanucservoamps-1-300x239.jpg\" \/>\n<meta name=\"author\" content=\"Brian Hughes\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@mroelectric\" \/>\n<meta name=\"twitter:site\" content=\"@mroelectric\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Brian Hughes\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/diagnosing-your-fanuc-current-alarm\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/diagnosing-your-fanuc-current-alarm\/\"},\"author\":{\"name\":\"Brian Hughes\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/17f5f3006a385c4cca90d6ba713324da\"},\"headline\":\"Diagnosing your FANUC Current Alarm\",\"datePublished\":\"2018-03-27T16:57:56+00:00\",\"dateModified\":\"2021-09-27T12:40:29+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/diagnosing-your-fanuc-current-alarm\/\"},\"wordCount\":330,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#organization\"},\"image\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/diagnosing-your-fanuc-current-alarm\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/fanucservoamps-1-300x239.jpg\",\"keywords\":[\"Alarms &amp; Faults\",\"Motors &amp; Drives\"],\"articleSection\":[\"Fanuc\",\"Troubleshooting &amp; Repair\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/www.mroelectric.com\/blog\/diagnosing-your-fanuc-current-alarm\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/diagnosing-your-fanuc-current-alarm\/\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/diagnosing-your-fanuc-current-alarm\/\",\"name\":\"Diagnosing your HC FANUC Alarms | MRO Electric and Supply Blog\",\"isPartOf\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/diagnosing-your-fanuc-current-alarm\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/diagnosing-your-fanuc-current-alarm\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/fanucservoamps-1-300x239.jpg\",\"datePublished\":\"2018-03-27T16:57:56+00:00\",\"dateModified\":\"2021-09-27T12:40:29+00:00\",\"description\":\"Figure out your High Current Fanuc Alarms here. MRO Electric and Supply has everything you need from Control Techniques, Siemens, Schneider Modicon, Yaskawa, etc. Visit our blog for information about products including pricing, specifications, and troubleshooting.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/diagnosing-your-fanuc-current-alarm\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.mroelectric.com\/blog\/diagnosing-your-fanuc-current-alarm\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/diagnosing-your-fanuc-current-alarm\/#primaryimage\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/fanucservoamps-1.jpg\",\"contentUrl\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/fanucservoamps-1.jpg\",\"width\":375,\"height\":299,\"caption\":\"FANUC Servo Amp\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/diagnosing-your-fanuc-current-alarm\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.mroelectric.com\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Diagnosing your FANUC Current Alarm\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#website\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/\",\"name\":\"MRO Electric Blog\",\"description\":\"Applications of PLCs, CNCs, and more!\",\"publisher\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.mroelectric.com\/blog\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#organization\",\"name\":\"MRO Electric and Supply\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro-logo-new_large2_blue-1.png\",\"contentUrl\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro-logo-new_large2_blue-1.png\",\"width\":430,\"height\":222,\"caption\":\"MRO Electric and Supply\"},\"image\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/mroelectric\/\",\"https:\/\/x.com\/mroelectric\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/17f5f3006a385c4cca90d6ba713324da\",\"name\":\"Brian Hughes\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/093bfbc42b7fee21edb03c0900b00f592f60a532b3a7541d4e0cf17ee991af35?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/093bfbc42b7fee21edb03c0900b00f592f60a532b3a7541d4e0cf17ee991af35?s=96&d=mm&r=g\",\"caption\":\"Brian Hughes\"},\"description\":\"Brian Hughes is a passionate electrical and content developer for MRO Electric. His main interests are in analog circuit design and solid state physics. Brian's professional background includes working on power system designs for commercial and industrial projects.\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/author\/bhughes\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Diagnosing your HC FANUC Alarms | MRO Electric and Supply Blog","description":"Figure out your High Current Fanuc Alarms here. MRO Electric and Supply has everything you need from Control Techniques, Siemens, Schneider Modicon, Yaskawa, etc. Visit our blog for information about products including pricing, specifications, and troubleshooting.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.mroelectric.com\/blog\/diagnosing-your-fanuc-current-alarm\/","og_locale":"en_US","og_type":"article","og_title":"Diagnosing your FANUC Current Alarm","og_description":"Figure out your High Current Fanuc Alarms here. MRO Electric and Supply has everything you need from Control Techniques, Siemens, Schneider Modicon, Yaskawa, etc. Visit our blog for information about products including pricing, specifications, and troubleshooting.","og_url":"https:\/\/www.mroelectric.com\/blog\/diagnosing-your-fanuc-current-alarm\/","og_site_name":"MRO Electric Blog","article_publisher":"https:\/\/www.facebook.com\/mroelectric\/","article_published_time":"2018-03-27T16:57:56+00:00","article_modified_time":"2021-09-27T12:40:29+00:00","og_image":[{"url":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/fanucservoamps-1-300x239.jpg","type":"","width":"","height":""}],"author":"Brian Hughes","twitter_card":"summary_large_image","twitter_creator":"@mroelectric","twitter_site":"@mroelectric","twitter_misc":{"Written by":"Brian Hughes","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.mroelectric.com\/blog\/diagnosing-your-fanuc-current-alarm\/#article","isPartOf":{"@id":"https:\/\/www.mroelectric.com\/blog\/diagnosing-your-fanuc-current-alarm\/"},"author":{"name":"Brian Hughes","@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/17f5f3006a385c4cca90d6ba713324da"},"headline":"Diagnosing your FANUC Current Alarm","datePublished":"2018-03-27T16:57:56+00:00","dateModified":"2021-09-27T12:40:29+00:00","mainEntityOfPage":{"@id":"https:\/\/www.mroelectric.com\/blog\/diagnosing-your-fanuc-current-alarm\/"},"wordCount":330,"commentCount":0,"publisher":{"@id":"https:\/\/www.mroelectric.com\/blog\/#organization"},"image":{"@id":"https:\/\/www.mroelectric.com\/blog\/diagnosing-your-fanuc-current-alarm\/#primaryimage"},"thumbnailUrl":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/fanucservoamps-1-300x239.jpg","keywords":["Alarms &amp; Faults","Motors &amp; Drives"],"articleSection":["Fanuc","Troubleshooting &amp; Repair"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.mroelectric.com\/blog\/diagnosing-your-fanuc-current-alarm\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.mroelectric.com\/blog\/diagnosing-your-fanuc-current-alarm\/","url":"https:\/\/www.mroelectric.com\/blog\/diagnosing-your-fanuc-current-alarm\/","name":"Diagnosing your HC FANUC Alarms | MRO Electric and Supply Blog","isPartOf":{"@id":"https:\/\/www.mroelectric.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.mroelectric.com\/blog\/diagnosing-your-fanuc-current-alarm\/#primaryimage"},"image":{"@id":"https:\/\/www.mroelectric.com\/blog\/diagnosing-your-fanuc-current-alarm\/#primaryimage"},"thumbnailUrl":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/fanucservoamps-1-300x239.jpg","datePublished":"2018-03-27T16:57:56+00:00","dateModified":"2021-09-27T12:40:29+00:00","description":"Figure out your High Current Fanuc Alarms here. MRO Electric and Supply has everything you need from Control Techniques, Siemens, Schneider Modicon, Yaskawa, etc. Visit our blog for information about products including pricing, specifications, and troubleshooting.","breadcrumb":{"@id":"https:\/\/www.mroelectric.com\/blog\/diagnosing-your-fanuc-current-alarm\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.mroelectric.com\/blog\/diagnosing-your-fanuc-current-alarm\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mroelectric.com\/blog\/diagnosing-your-fanuc-current-alarm\/#primaryimage","url":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/fanucservoamps-1.jpg","contentUrl":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/fanucservoamps-1.jpg","width":375,"height":299,"caption":"FANUC Servo Amp"},{"@type":"BreadcrumbList","@id":"https:\/\/www.mroelectric.com\/blog\/diagnosing-your-fanuc-current-alarm\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.mroelectric.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Diagnosing your FANUC Current Alarm"}]},{"@type":"WebSite","@id":"https:\/\/www.mroelectric.com\/blog\/#website","url":"https:\/\/www.mroelectric.com\/blog\/","name":"MRO Electric Blog","description":"Applications of PLCs, CNCs, and more!","publisher":{"@id":"https:\/\/www.mroelectric.com\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.mroelectric.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.mroelectric.com\/blog\/#organization","name":"MRO Electric and Supply","url":"https:\/\/www.mroelectric.com\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro-logo-new_large2_blue-1.png","contentUrl":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro-logo-new_large2_blue-1.png","width":430,"height":222,"caption":"MRO Electric and Supply"},"image":{"@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/mroelectric\/","https:\/\/x.com\/mroelectric"]},{"@type":"Person","@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/17f5f3006a385c4cca90d6ba713324da","name":"Brian Hughes","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/093bfbc42b7fee21edb03c0900b00f592f60a532b3a7541d4e0cf17ee991af35?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/093bfbc42b7fee21edb03c0900b00f592f60a532b3a7541d4e0cf17ee991af35?s=96&d=mm&r=g","caption":"Brian Hughes"},"description":"Brian Hughes is a passionate electrical and content developer for MRO Electric. His main interests are in analog circuit design and solid state physics. Brian's professional background includes working on power system designs for commercial and industrial projects.","url":"https:\/\/www.mroelectric.com\/blog\/author\/bhughes\/"}]}},"modified_by":"Leanna Cota","_links":{"self":[{"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/posts\/3061","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/comments?post=3061"}],"version-history":[{"count":7,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/posts\/3061\/revisions"}],"predecessor-version":[{"id":4935,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/posts\/3061\/revisions\/4935"}],"wp:attachment":[{"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/media?parent=3061"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/categories?post=3061"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/tags?post=3061"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}