{"id":542,"date":"2015-09-08T12:15:31","date_gmt":"2015-09-08T12:15:31","guid":{"rendered":"http:\/\/www.mroelectric.com\/blog\/?p=542"},"modified":"2019-05-28T09:30:17","modified_gmt":"2019-05-28T13:30:17","slug":"modbus-plus-and-sy-max-ethernet-network-errors","status":"publish","type":"post","link":"https:\/\/www.mroelectric.com\/blog\/modbus-plus-and-sy-max-ethernet-network-errors\/","title":{"rendered":"Modbus Plus and SY MAX Ethernet Network Errors"},"content":{"rendered":"<p>SY\/MAX Ethernet transaction function error codes for <a href=\"https:\/\/www.mroelectric.com\/category\/modbus\/2\">Modbus<\/a> Plus appear as <b>Mmss<\/b>, where <b>M<\/b> is the high code, <b>m<\/b> is the low code, and <b>ss<\/b> is the subcode. Read below for information regarding possible <a href=\"https:\/\/www.mroelectric.com\/schneider-electric\/1\">Schneider Module Modbus Plus<\/a> and SY MAX Ethernet Network Errors.<\/p>\n<p><!--more--><\/p>\n<h4>Schneider Module Modbus Plus and SY MAX Ethernet Network Errors<\/h4>\n<table  class=\" table table-hover\" >\n<tbody>\n<tr>\n<th>Hex. Error Code<\/th>\n<th>Description<\/th>\n<\/tr>\n<tr class=\"offset-row\">\n<td class=\"first-col-field\">1001<\/td>\n<td>Abort by user<\/td>\n<\/tr>\n<tr>\n<td class=\"first-col-field\">2001<\/td>\n<td>An operation type that is not supported has been specified in the control block<\/td>\n<\/tr>\n<tr class=\"offset-row\">\n<td class=\"first-col-field\">2002<\/td>\n<td>One or more control block parameters were modified while the <code>MSTR<\/code> element<br \/>\nwas active (this only applies to operations which require several cycles for<br \/>\ncompletion). Control block parameters my only be modified in inactive <code>MSTR<\/code><br \/>\ncomponents.<\/td>\n<\/tr>\n<tr>\n<td class=\"first-col-field\">2003<\/td>\n<td>Invalid value in the length field of the control block<\/td>\n<\/tr>\n<tr class=\"offset-row\">\n<td class=\"first-col-field\">2004<\/td>\n<td>Invalid value in the offset field of the control block<\/td>\n<\/tr>\n<tr>\n<td class=\"first-col-field\">2005<\/td>\n<td>Invalid value in the length and offset fields of the control block<\/td>\n<\/tr>\n<tr class=\"offset-row\">\n<td class=\"first-col-field\">2006<\/td>\n<td>Unauthorized data field on slave<\/td>\n<\/tr>\n<tr>\n<td class=\"first-col-field\">2007<\/td>\n<td>Unauthorized network field on slave<\/td>\n<\/tr>\n<tr class=\"offset-row\">\n<td class=\"first-col-field\">2008<\/td>\n<td>Unauthorized network routing path on slave<\/td>\n<\/tr>\n<tr>\n<td class=\"first-col-field\">2009<\/td>\n<td>Routing path equivalent to their own address<\/td>\n<\/tr>\n<tr class=\"offset-row\">\n<td class=\"first-col-field\">200A<\/td>\n<td>Attempt to get more global data words than available<\/td>\n<\/tr>\n<tr>\n<td class=\"first-col-field\">200C<\/td>\n<td>Bad pattern for change address request<\/td>\n<\/tr>\n<tr class=\"offset-row\">\n<td class=\"first-col-field\">200D<\/td>\n<td>Bad address for change address request<\/td>\n<\/tr>\n<tr>\n<td class=\"first-col-field\">200E<\/td>\n<td>The control block is not assigned, or parts of the control block are located<br \/>\noutside of the %MW (4x) range.<\/td>\n<\/tr>\n<tr class=\"offset-row\">\n<td class=\"first-col-field\">30ss<\/td>\n<td>Exceptional response by Modbus slave<\/td>\n<\/tr>\n<tr>\n<td class=\"first-col-field\">4001<\/td>\n<td>Inconsistent response by Modbus slave<\/td>\n<\/tr>\n<tr class=\"offset-row\">\n<td class=\"first-col-field\">5001<\/td>\n<td>Inconsistent response by the network<\/td>\n<\/tr>\n<tr>\n<td class=\"first-col-field\">6007<\/td>\n<td>Invalid slot ID<\/td>\n<\/tr>\n<tr class=\"offset-row\">\n<td class=\"first-col-field\">6mss<\/td>\n<td>Routing path error<br \/>\nThe subfield m shows where the error occurred (a 0 value means local node, 2 means 2nd device in route, etc).<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>If you are interested in spare parts or more information regarding <a href=\"https:\/\/www.mroelectric.com\/schneider-electric\/1\">Schneider Electric Drives<\/a>, feel free to check out our <a href=\"https:\/\/www.mroelectric.com\/schneider-electric\/modicon-quantum\/1\">Modicon Quantum Modules<\/a>!<\/p>\n<style type=\"text\/css\">\nh4 {<br \/>color: #009140;<br \/>}<br \/>table {<br \/>border-collapse: collapse;<br \/>}<br \/>td, th {<br \/>padding: 5px;<br \/>padding-top: 0;<br \/>padding-bottom: 0;<br \/>vertical-align: top;<br \/>}<br \/>th {<br \/>border-bottom: solid #70AD47 2px;<br \/>text-transform: lowercase;<br \/>}<br \/>th:first-letter {<br \/>text-transform: uppercase;<br \/>}<br \/>td {<br \/>border-bottom: solid #70AD47 1px;<br \/>line-height: 1.65;<br \/>}<br \/>.first-col-field {<br \/>border-right: solid #70AD47 1px;<br \/>}<br \/>.offset-row {<br \/>background-color: #E2EFD9;<br \/>}<br \/>.code {<br \/>color: grey;<br \/>}<br \/>.tab {<br \/>padding-left: 5em;<br \/>}<br \/>.figure-container {<br \/>display: block;<br \/>width: 90%;<br \/>margin-top: 5px;<br \/>margin-left: auto;<br \/>margin-right: auto;<br \/>border: solid black 1px !important;<br \/>padding: 5px;<br \/>margin-bottom: 7px;<br \/>}<br \/>.figure {<br \/>border: none;<br \/>margin-bottom: -5px;<br \/>}<br \/>.figure th, td {<br \/>border: none;<br \/>}<br \/>legend {<br \/>margin-top: -25px;<br \/>padding-top: 0;<br \/>}<br \/>#first-figure-line {<br \/>display: block;<br \/>margin-top: -25px;<br \/>margin-bottom: -25px;<br \/>}<br \/>#main-image {<br \/>display: inline-block;<br \/>float: right;<br \/>padding-left: 15px;<br \/>padding-bottom: 15px;<br \/>}<br \/>.align-justify {<br \/>display: inline-block;<br \/>text-align: justify;<br \/>}<br \/>.clear {<br \/>clear: left;<br \/>}<br \/><\/style>\n","protected":false},"excerpt":{"rendered":"<p>SY\/MAX Ethernet transaction function error codes for Modbus Plus appear as Mmss, where M is the high code, m is the low code, and ss is the subcode. Read below for information regarding possible Schneider Module Modbus Plus and SY MAX Ethernet Network Errors.<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"","_lmt_disable":"","_exactmetrics_skip_tracking":false,"_exactmetrics_sitenote_active":false,"_exactmetrics_sitenote_note":"","_exactmetrics_sitenote_category":0,"ngg_post_thumbnail":0,"footnotes":""},"categories":[96,12],"tags":[],"class_list":["post-542","post","type-post","status-publish","format-standard","hentry","category-schneider-electric","category-troubleshooting-and-repair"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v25.3.1 (Yoast SEO v25.3.1) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Modbus Plus and SY MAX Ethernet Network Errors<\/title>\n<meta name=\"description\" content=\"Modbus Plus and SY MAX Ethernet Network Errors. MRO Electric supplies new and remanufactured Modicon PLCs with free same-day shipping on all orders.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.mroelectric.com\/blog\/modbus-plus-and-sy-max-ethernet-network-errors\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Modbus Plus and SY MAX Ethernet Network Errors\" \/>\n<meta property=\"og:description\" content=\"Modbus Plus and SY MAX Ethernet Network Errors. MRO Electric supplies new and remanufactured Modicon PLCs with free same-day shipping on all orders.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.mroelectric.com\/blog\/modbus-plus-and-sy-max-ethernet-network-errors\/\" \/>\n<meta property=\"og:site_name\" content=\"MRO Electric Blog\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/mroelectric\/\" \/>\n<meta property=\"article:published_time\" content=\"2015-09-08T12:15:31+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2019-05-28T13:30:17+00:00\" \/>\n<meta name=\"author\" content=\"Joe Kaminski\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@mroelectric\" \/>\n<meta name=\"twitter:site\" content=\"@mroelectric\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Joe Kaminski\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/modbus-plus-and-sy-max-ethernet-network-errors\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/modbus-plus-and-sy-max-ethernet-network-errors\/\"},\"author\":{\"name\":\"Joe Kaminski\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/b993515a2417163a23dfe88597c8d13a\"},\"headline\":\"Modbus Plus and SY MAX Ethernet Network Errors\",\"datePublished\":\"2015-09-08T12:15:31+00:00\",\"dateModified\":\"2019-05-28T13:30:17+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/modbus-plus-and-sy-max-ethernet-network-errors\/\"},\"wordCount\":283,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#organization\"},\"articleSection\":[\"Schneider Electric\",\"Troubleshooting &amp; Repair\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/www.mroelectric.com\/blog\/modbus-plus-and-sy-max-ethernet-network-errors\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/modbus-plus-and-sy-max-ethernet-network-errors\/\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/modbus-plus-and-sy-max-ethernet-network-errors\/\",\"name\":\"Modbus Plus and SY MAX Ethernet Network Errors\",\"isPartOf\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#website\"},\"datePublished\":\"2015-09-08T12:15:31+00:00\",\"dateModified\":\"2019-05-28T13:30:17+00:00\",\"description\":\"Modbus Plus and SY MAX Ethernet Network Errors. MRO Electric supplies new and remanufactured Modicon PLCs with free same-day shipping on all orders.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/modbus-plus-and-sy-max-ethernet-network-errors\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.mroelectric.com\/blog\/modbus-plus-and-sy-max-ethernet-network-errors\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/modbus-plus-and-sy-max-ethernet-network-errors\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.mroelectric.com\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Modbus Plus and SY MAX Ethernet Network Errors\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#website\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/\",\"name\":\"MRO Electric Blog\",\"description\":\"Applications of PLCs, CNCs, and more!\",\"publisher\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.mroelectric.com\/blog\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#organization\",\"name\":\"MRO Electric and Supply\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro-logo-new_large2_blue-1.png\",\"contentUrl\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro-logo-new_large2_blue-1.png\",\"width\":430,\"height\":222,\"caption\":\"MRO Electric and Supply\"},\"image\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/mroelectric\/\",\"https:\/\/x.com\/mroelectric\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/b993515a2417163a23dfe88597c8d13a\",\"name\":\"Joe Kaminski\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/fb7c0d641ed541ad912b27609e8079304fc356be7b5b53578b32ad3fa973f506?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/fb7c0d641ed541ad912b27609e8079304fc356be7b5b53578b32ad3fa973f506?s=96&d=mm&r=g\",\"caption\":\"Joe Kaminski\"},\"description\":\"Joe Kaminski is an industrial automation specialist at MRO Electric. He has a background in industrial engineering and supply chain management. Joe has worked in the automation industry for over 10 years providing support to some of the largest companies in the world. For more info, visit www.mroelectric.com.\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/author\/jadmin\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Modbus Plus and SY MAX Ethernet Network Errors","description":"Modbus Plus and SY MAX Ethernet Network Errors. MRO Electric supplies new and remanufactured Modicon PLCs with free same-day shipping on all orders.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.mroelectric.com\/blog\/modbus-plus-and-sy-max-ethernet-network-errors\/","og_locale":"en_US","og_type":"article","og_title":"Modbus Plus and SY MAX Ethernet Network Errors","og_description":"Modbus Plus and SY MAX Ethernet Network Errors. MRO Electric supplies new and remanufactured Modicon PLCs with free same-day shipping on all orders.","og_url":"https:\/\/www.mroelectric.com\/blog\/modbus-plus-and-sy-max-ethernet-network-errors\/","og_site_name":"MRO Electric Blog","article_publisher":"https:\/\/www.facebook.com\/mroelectric\/","article_published_time":"2015-09-08T12:15:31+00:00","article_modified_time":"2019-05-28T13:30:17+00:00","author":"Joe Kaminski","twitter_card":"summary_large_image","twitter_creator":"@mroelectric","twitter_site":"@mroelectric","twitter_misc":{"Written by":"Joe Kaminski","Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.mroelectric.com\/blog\/modbus-plus-and-sy-max-ethernet-network-errors\/#article","isPartOf":{"@id":"https:\/\/www.mroelectric.com\/blog\/modbus-plus-and-sy-max-ethernet-network-errors\/"},"author":{"name":"Joe Kaminski","@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/b993515a2417163a23dfe88597c8d13a"},"headline":"Modbus Plus and SY MAX Ethernet Network Errors","datePublished":"2015-09-08T12:15:31+00:00","dateModified":"2019-05-28T13:30:17+00:00","mainEntityOfPage":{"@id":"https:\/\/www.mroelectric.com\/blog\/modbus-plus-and-sy-max-ethernet-network-errors\/"},"wordCount":283,"commentCount":0,"publisher":{"@id":"https:\/\/www.mroelectric.com\/blog\/#organization"},"articleSection":["Schneider Electric","Troubleshooting &amp; Repair"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.mroelectric.com\/blog\/modbus-plus-and-sy-max-ethernet-network-errors\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.mroelectric.com\/blog\/modbus-plus-and-sy-max-ethernet-network-errors\/","url":"https:\/\/www.mroelectric.com\/blog\/modbus-plus-and-sy-max-ethernet-network-errors\/","name":"Modbus Plus and SY MAX Ethernet Network Errors","isPartOf":{"@id":"https:\/\/www.mroelectric.com\/blog\/#website"},"datePublished":"2015-09-08T12:15:31+00:00","dateModified":"2019-05-28T13:30:17+00:00","description":"Modbus Plus and SY MAX Ethernet Network Errors. MRO Electric supplies new and remanufactured Modicon PLCs with free same-day shipping on all orders.","breadcrumb":{"@id":"https:\/\/www.mroelectric.com\/blog\/modbus-plus-and-sy-max-ethernet-network-errors\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.mroelectric.com\/blog\/modbus-plus-and-sy-max-ethernet-network-errors\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.mroelectric.com\/blog\/modbus-plus-and-sy-max-ethernet-network-errors\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.mroelectric.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Modbus Plus and SY MAX Ethernet Network Errors"}]},{"@type":"WebSite","@id":"https:\/\/www.mroelectric.com\/blog\/#website","url":"https:\/\/www.mroelectric.com\/blog\/","name":"MRO Electric Blog","description":"Applications of PLCs, CNCs, and more!","publisher":{"@id":"https:\/\/www.mroelectric.com\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.mroelectric.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.mroelectric.com\/blog\/#organization","name":"MRO Electric and Supply","url":"https:\/\/www.mroelectric.com\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro-logo-new_large2_blue-1.png","contentUrl":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro-logo-new_large2_blue-1.png","width":430,"height":222,"caption":"MRO Electric and Supply"},"image":{"@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/mroelectric\/","https:\/\/x.com\/mroelectric"]},{"@type":"Person","@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/b993515a2417163a23dfe88597c8d13a","name":"Joe Kaminski","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/fb7c0d641ed541ad912b27609e8079304fc356be7b5b53578b32ad3fa973f506?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/fb7c0d641ed541ad912b27609e8079304fc356be7b5b53578b32ad3fa973f506?s=96&d=mm&r=g","caption":"Joe Kaminski"},"description":"Joe Kaminski is an industrial automation specialist at MRO Electric. He has a background in industrial engineering and supply chain management. Joe has worked in the automation industry for over 10 years providing support to some of the largest companies in the world. For more info, visit www.mroelectric.com.","url":"https:\/\/www.mroelectric.com\/blog\/author\/jadmin\/"}]}},"modified_by":"Ryan Dickinson","_links":{"self":[{"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/posts\/542","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/comments?post=542"}],"version-history":[{"count":6,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/posts\/542\/revisions"}],"predecessor-version":[{"id":3744,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/posts\/542\/revisions\/3744"}],"wp:attachment":[{"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/media?parent=542"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/categories?post=542"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/tags?post=542"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}