{"id":6106,"date":"2025-05-01T17:41:45","date_gmt":"2025-05-01T21:41:45","guid":{"rendered":"https:\/\/www.mroelectric.com\/blog\/?p=6106"},"modified":"2025-06-10T15:17:08","modified_gmt":"2025-06-10T19:17:08","slug":"servo-amplifiers-diagnosing-and-fixing-ground-faults","status":"publish","type":"post","link":"https:\/\/www.mroelectric.com\/blog\/servo-amplifiers-diagnosing-and-fixing-ground-faults\/","title":{"rendered":"Servo Amplifiers: Diagnosing and Fixing Ground Faults"},"content":{"rendered":"\n<p>Ground faults in a servo amplifier system can lead to erratic behavior, unexpected shutdowns, or even permanent damage to equipment. A ground fault occurs when an unintended electrical connection exists between a live conductor and ground, causing leakage currents that disrupt normal operation. Diagnosing and fixing these faults promptly is essential for maintaining system reliability and safety.<\/p>\n\n\n\n<p>This article provides a step-by-step guide to identifying and resolving ground faults in servo amplifier systems.<\/p>\n\n\n<a class=\"wp-block-read-more\" href=\"https:\/\/www.mroelectric.com\/blog\/servo-amplifiers-diagnosing-and-fixing-ground-faults\/\" target=\"_self\">Read more<span class=\"screen-reader-text\">: Servo Amplifiers: Diagnosing and Fixing Ground Faults<\/span><\/a>\n\n\n<h2 class=\"wp-block-heading\" id=\"h-recognizing-the-symptoms-of-a-ground-fault\">Recognizing the Symptoms of a Ground Fault<\/h2>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex\">\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex\">\n<p>The quintessential step to repairing a ground fault is being able to recognize and identify symptoms.  After all, you can&#8217;t fix a problem if you don&#8217;t know what the problem looks like.  When looking for symptoms of a ground fault keep an eye out for:<br><br><strong>Unexpected shutdowns or fault alarms<\/strong> (e.g., &#8220;Ground Fault&#8221; error on the drive)<\/p>\n\n\n\n<p><strong>Erratic motor behavior<\/strong> (jittering, unexpected movements, or loss of torque)<\/p>\n\n\n\n<p><strong>Burning smells or overheating components<\/strong><\/p>\n\n\n\n<p><strong>Electrical noise affecting feedback devices (encoders\/resolvers)<\/strong><\/p>\n\n\n\n<p><strong>Tripped circuit breakers or ground fault protection devices<\/strong><\/p>\n<\/div>\n<\/div>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"What are Ground Faults? | Repair and Replace\" width=\"648\" height=\"365\" src=\"https:\/\/www.youtube.com\/embed\/LyAtuR2qtMA?feature=oembed&#038;enablejsapi=1&#038;origin=https:\/\/www.mroelectric.com\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-safety-precautions\">Safety Precautions<\/h2>\n\n\n\n<p>Once you&#8217;ve recognized the symptoms of a ground fault, you may have that impulse of wanting to go straight into poking around and tinkering with the drive.  However, before you do that, you need to take precautionary steps to ensure your safety.  Exercising the following precautions will prevent the chances of a hazard occurring, increasing your safety.<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Make sure the power is disconnected and verify with a multi-meter. <\/strong><\/li>\n\n\n\n<li><strong>Ensure the capacitors are discharged.<\/strong><\/li>\n\n\n\n<li><strong>Use insulated tools and wear personal protective equipment (PPE)<\/strong><br>&#8211; Companies like <a href=\"https:\/\/refrigiwear.com\/\" class=\"external\" rel=\"nofollow\">RefrigiWear<\/a> offer a selection of insulated foot wear that protects against high voltage.<\/li>\n\n\n\n<li><strong>Follow lockout\/tagout procedures if working in an industrial environment. <\/strong><\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-isolating-the-fault\">Isolating the Fault<\/h2>\n\n\n\n<p>Once you are confident that all safety precautions have been taken and that the system is completely off and all power fully dispersed, then you can proceed forwards with isolating the fault.  Here are a few ways you can  isolate a fault.<\/p>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex\">\n<h4 class=\"wp-block-heading\" id=\"h-checking-the-power-supply\">Checking the Power Supply<\/h4>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex\">\n<p>Using a multi-meter, you can check the power supply to see if you get a low resistance rating that would indicate a short in the ground.  <\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-checking-the-motor-windings\">Checking the Motor Windings<\/h4>\n\n\n\n<p>You can test the motor windings by disconnecting the motor cables from the power supply.  Next, measure the resistance between each motor phase and the ground.  There should be high resistance  (&gt;1M\u03a9).  A low resistance is an indicator of a short in the motor frame.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-check-encoders-and-resolver-connections\">Check Encoders and Resolver Connections<\/h4>\n\n\n\n<p>Another way is to check encoders and resolvers for any exposed or damaged wires.  You can check do this by checking for continuity between signal lines and ground.  There should be no direct connection.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-inspecting-the-servo-amplifier\">Inspecting the Servo Amplifier<\/h4>\n\n\n\n<p>If you need to check the servo amplifier, look for obvious visual signs like burnt components, blown fuses, or discolored PCBs.  Using a multi-meter test the DC bus capacitors for leakage or short circuits.  Double check proper grounding of the amplifier chassis. <\/p>\n<\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-repairing-the-ground-fault\">Repairing the Ground Fault<\/h2>\n\n\n\n<p>While diagnosing and isolating faults are lightly challenging but doable for most people, it is advised that if you are not most versed in servo amplifiers then reach out to a professional for repairs. <\/p>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex\">\n<h4 class=\"wp-block-heading\" id=\"h-repair-replace-damaged-wiring\">Repair\/Replace Damaged Wiring<\/h4>\n\n\n\n<p>If the issue is with the cables then replace any damaged or frayed cables. Also, check for strain relief on connection points to the devices.  Good strain relief prevents future wear of cables. Make sure you use shielded cables for motor and feedback connections.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-address-motor-issues\">Address Motor Issues<\/h4>\n\n\n\n<p>Check your motor bearings as mechanical wear can cause internal shorts. If your motor windings are shorted, replace the motor. <\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-replacing-components\">Replacing Components<\/h4>\n\n\n\n<p>Replace blown out PCB and capacitors.  Double check the amplifier is properly grounded. Be sure to check the specs before doing so.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-verify-grounding-scheme\">Verify Grounding Scheme<\/h4>\n\n\n\n<p>When verifying the grounding scheme, make sure the system has a single-point ground to avoid ground loops. Also, make sure wires are properly sized and securely connected<\/p>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-after-repair-testing\">After Repair Testing<\/h2>\n\n\n\n<p>After repairs are done, before you restore power, make sure to give another test. Use a multimeter to test resistance on motor windings and cables. After that, gradually power up the system and monitor for fault messages. Finally, run the servo motor at low speed and check for any odd sounds or for overheating.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-conclusion\">Conclusion<\/h2>\n\n\n\n<p>Ground faults in servo amplifier systems can cause significant downtime if not addressed properly. By following a structured diagnostic approach\u2014checking power supplies, motor windings, feedback cables, and amplifier components\u2014you can efficiently locate and resolve the issue. Always prioritize safety, use proper testing equipment, and ensure correct grounding practices to prevent future faults.<\/p>\n\n\n\n<p>Regular preventive maintenance, including insulation resistance checks and visual inspections, can help detect ground faults early and extend the lifespan of your servo system.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-servo-amplifier-need-replacing\">Servo Amplifier Need Replacing?<\/h2>\n\n\n\n<p>If you have a servo amplifier that needs replacing, let our team of experts help you get your system back up and running.  <\/p>\n\n\n\n<h3 class=\"wp-block-heading has-text-align-center\" id=\"h-contact-us\">Contact Us<\/h3>\n\n\n\n<div class=\"cta-wrapper\">\n  <div class=\"cta-inner\">\n    <a href=\"mailto:sales@mroelectric.com\" class=\"btn-custom md blue w-150 font-weight-bold text-center\">Email<\/a>\n    <a href=\"tel:+18006918511\" class=\"btn-custom md blue w-150 font-weight-bold text-center\">Call<\/a>\n  <\/div>\n<\/div>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Ground faults in a servo amplifier system can lead to erratic behavior, unexpected shutdowns, or even permanent damage to equipment. A ground fault occurs when an unintended electrical connection exists between a live conductor and ground, causing leakage currents that disrupt normal operation. Diagnosing and fixing these faults promptly is essential for maintaining system reliability [&hellip;]<\/p>\n","protected":false},"author":9,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"","_lmt_disable":"","_exactmetrics_skip_tracking":false,"_exactmetrics_sitenote_active":false,"_exactmetrics_sitenote_note":"","_exactmetrics_sitenote_category":0,"ngg_post_thumbnail":0,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-6106","post","type-post","status-publish","format-standard","hentry","category-other"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v25.3.1 (Yoast SEO v25.3.1) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Servo Amplifiers: Diagnosing and Fixing Ground Faults - MRO Electric Blog<\/title>\n<meta name=\"description\" content=\"Ground faults in servo amplifiers occur when current leaks to ground. This causes malfunctions. They require prompt repair to prevent equipment failure.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.mroelectric.com\/blog\/servo-amplifiers-diagnosing-and-fixing-ground-faults\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Servo Amplifiers: Diagnosing and Fixing Ground Faults\" \/>\n<meta property=\"og:description\" content=\"Ground faults in servo amplifiers occur when current leaks to ground. This causes malfunctions. They require prompt repair to prevent equipment failure.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.mroelectric.com\/blog\/servo-amplifiers-diagnosing-and-fixing-ground-faults\/\" \/>\n<meta property=\"og:site_name\" content=\"MRO Electric Blog\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/mroelectric\/\" \/>\n<meta property=\"article:published_time\" content=\"2025-05-01T21:41:45+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-06-10T19:17:08+00:00\" \/>\n<meta name=\"author\" content=\"Ken Cheng\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@mroelectric\" \/>\n<meta name=\"twitter:site\" content=\"@mroelectric\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Ken Cheng\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/servo-amplifiers-diagnosing-and-fixing-ground-faults\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/servo-amplifiers-diagnosing-and-fixing-ground-faults\/\"},\"author\":{\"name\":\"Ken Cheng\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/a713132dec572f9804740c785dbfd535\"},\"headline\":\"Servo Amplifiers: Diagnosing and Fixing Ground Faults\",\"datePublished\":\"2025-05-01T21:41:45+00:00\",\"dateModified\":\"2025-06-10T19:17:08+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/servo-amplifiers-diagnosing-and-fixing-ground-faults\/\"},\"wordCount\":836,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#organization\"},\"articleSection\":[\"Other\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/www.mroelectric.com\/blog\/servo-amplifiers-diagnosing-and-fixing-ground-faults\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/servo-amplifiers-diagnosing-and-fixing-ground-faults\/\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/servo-amplifiers-diagnosing-and-fixing-ground-faults\/\",\"name\":\"Servo Amplifiers: Diagnosing and Fixing Ground Faults - MRO Electric Blog\",\"isPartOf\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#website\"},\"datePublished\":\"2025-05-01T21:41:45+00:00\",\"dateModified\":\"2025-06-10T19:17:08+00:00\",\"description\":\"Ground faults in servo amplifiers occur when current leaks to ground. This causes malfunctions. They require prompt repair to prevent equipment failure.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/servo-amplifiers-diagnosing-and-fixing-ground-faults\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.mroelectric.com\/blog\/servo-amplifiers-diagnosing-and-fixing-ground-faults\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/servo-amplifiers-diagnosing-and-fixing-ground-faults\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.mroelectric.com\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Servo Amplifiers: Diagnosing and Fixing Ground Faults\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#website\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/\",\"name\":\"MRO Electric Blog\",\"description\":\"Applications of PLCs, CNCs, and more!\",\"publisher\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.mroelectric.com\/blog\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#organization\",\"name\":\"MRO Electric and Supply\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro-logo-new_large2_blue-1.png\",\"contentUrl\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro-logo-new_large2_blue-1.png\",\"width\":430,\"height\":222,\"caption\":\"MRO Electric and Supply\"},\"image\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/mroelectric\/\",\"https:\/\/x.com\/mroelectric\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/a713132dec572f9804740c785dbfd535\",\"name\":\"Ken Cheng\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/95800a789a88238ab489af0f77c15fe47a3bf19a528f02edb6a1b57e4587bb5f?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/95800a789a88238ab489af0f77c15fe47a3bf19a528f02edb6a1b57e4587bb5f?s=96&d=mm&r=g\",\"caption\":\"Ken Cheng\"},\"sameAs\":[\"http:\/\/www.mroelectric.com\"],\"url\":\"https:\/\/www.mroelectric.com\/blog\/author\/kcheng\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Servo Amplifiers: Diagnosing and Fixing Ground Faults - MRO Electric Blog","description":"Ground faults in servo amplifiers occur when current leaks to ground. This causes malfunctions. They require prompt repair to prevent equipment failure.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.mroelectric.com\/blog\/servo-amplifiers-diagnosing-and-fixing-ground-faults\/","og_locale":"en_US","og_type":"article","og_title":"Servo Amplifiers: Diagnosing and Fixing Ground Faults","og_description":"Ground faults in servo amplifiers occur when current leaks to ground. This causes malfunctions. They require prompt repair to prevent equipment failure.","og_url":"https:\/\/www.mroelectric.com\/blog\/servo-amplifiers-diagnosing-and-fixing-ground-faults\/","og_site_name":"MRO Electric Blog","article_publisher":"https:\/\/www.facebook.com\/mroelectric\/","article_published_time":"2025-05-01T21:41:45+00:00","article_modified_time":"2025-06-10T19:17:08+00:00","author":"Ken Cheng","twitter_card":"summary_large_image","twitter_creator":"@mroelectric","twitter_site":"@mroelectric","twitter_misc":{"Written by":"Ken Cheng","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.mroelectric.com\/blog\/servo-amplifiers-diagnosing-and-fixing-ground-faults\/#article","isPartOf":{"@id":"https:\/\/www.mroelectric.com\/blog\/servo-amplifiers-diagnosing-and-fixing-ground-faults\/"},"author":{"name":"Ken Cheng","@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/a713132dec572f9804740c785dbfd535"},"headline":"Servo Amplifiers: Diagnosing and Fixing Ground Faults","datePublished":"2025-05-01T21:41:45+00:00","dateModified":"2025-06-10T19:17:08+00:00","mainEntityOfPage":{"@id":"https:\/\/www.mroelectric.com\/blog\/servo-amplifiers-diagnosing-and-fixing-ground-faults\/"},"wordCount":836,"commentCount":0,"publisher":{"@id":"https:\/\/www.mroelectric.com\/blog\/#organization"},"articleSection":["Other"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.mroelectric.com\/blog\/servo-amplifiers-diagnosing-and-fixing-ground-faults\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.mroelectric.com\/blog\/servo-amplifiers-diagnosing-and-fixing-ground-faults\/","url":"https:\/\/www.mroelectric.com\/blog\/servo-amplifiers-diagnosing-and-fixing-ground-faults\/","name":"Servo Amplifiers: Diagnosing and Fixing Ground Faults - MRO Electric Blog","isPartOf":{"@id":"https:\/\/www.mroelectric.com\/blog\/#website"},"datePublished":"2025-05-01T21:41:45+00:00","dateModified":"2025-06-10T19:17:08+00:00","description":"Ground faults in servo amplifiers occur when current leaks to ground. This causes malfunctions. They require prompt repair to prevent equipment failure.","breadcrumb":{"@id":"https:\/\/www.mroelectric.com\/blog\/servo-amplifiers-diagnosing-and-fixing-ground-faults\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.mroelectric.com\/blog\/servo-amplifiers-diagnosing-and-fixing-ground-faults\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.mroelectric.com\/blog\/servo-amplifiers-diagnosing-and-fixing-ground-faults\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.mroelectric.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Servo Amplifiers: Diagnosing and Fixing Ground Faults"}]},{"@type":"WebSite","@id":"https:\/\/www.mroelectric.com\/blog\/#website","url":"https:\/\/www.mroelectric.com\/blog\/","name":"MRO Electric Blog","description":"Applications of PLCs, CNCs, and more!","publisher":{"@id":"https:\/\/www.mroelectric.com\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.mroelectric.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.mroelectric.com\/blog\/#organization","name":"MRO Electric and Supply","url":"https:\/\/www.mroelectric.com\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro-logo-new_large2_blue-1.png","contentUrl":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro-logo-new_large2_blue-1.png","width":430,"height":222,"caption":"MRO Electric and Supply"},"image":{"@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/mroelectric\/","https:\/\/x.com\/mroelectric"]},{"@type":"Person","@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/a713132dec572f9804740c785dbfd535","name":"Ken Cheng","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/95800a789a88238ab489af0f77c15fe47a3bf19a528f02edb6a1b57e4587bb5f?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/95800a789a88238ab489af0f77c15fe47a3bf19a528f02edb6a1b57e4587bb5f?s=96&d=mm&r=g","caption":"Ken Cheng"},"sameAs":["http:\/\/www.mroelectric.com"],"url":"https:\/\/www.mroelectric.com\/blog\/author\/kcheng\/"}]}},"modified_by":"Joe Kaminski","_links":{"self":[{"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/posts\/6106","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/comments?post=6106"}],"version-history":[{"count":7,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/posts\/6106\/revisions"}],"predecessor-version":[{"id":6156,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/posts\/6106\/revisions\/6156"}],"wp:attachment":[{"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/media?parent=6106"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/categories?post=6106"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/tags?post=6106"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}