{"id":962,"date":"2016-04-07T16:46:03","date_gmt":"2016-04-07T20:46:03","guid":{"rendered":"https:\/\/www.mroelectric.com\/blog\/?p=962"},"modified":"2019-08-29T15:56:18","modified_gmt":"2019-08-29T19:56:18","slug":"simodrive-f-16-alarm-code-troubleshooting","status":"publish","type":"post","link":"https:\/\/www.mroelectric.com\/blog\/simodrive-f-16-alarm-code-troubleshooting\/","title":{"rendered":"Simodrive F-16 Alarm Code Troubleshooting &#038; Diagnostics"},"content":{"rendered":"<p>We recently had a customer install a replacement <a href=\"https:\/\/www.mroelectric.com\/product\/6SN1121-0BA11-0AA1\">6SN1121-0BA11-0AA1<\/a> card into a <a href=\"https:\/\/www.mroelectric.com\/product\/6SN1123-1AA00-0EA1\">6SN1123-1AA00-0EA1<\/a> power module. When they installed the card it came up with an F-16 alarm code on the display of it, which references an &#8220;Illegal Power Module.&#8221; Using the instructions in the manual for the start-up of a replacement <a href=\"https:\/\/www.mroelectric.com\/siemens\/simodrive\/1\">Simodrive<\/a> card or power module we were able to get the customer back up and running with the steps below.<\/p>\n<p><!--more--><\/p>\n<p>On the 6SN1121-0BA11-0AA1, the F-16 Illegal Power module code means that either there is an incorrect code number 3 selected in P-095 (for power modules without automatic recognition) or there is an incorrect number selected in P-095 (for power modules with automatic recognition). To fix this, you just need to load the correct code number into parameter P-095 on the control unit. The list of the power module codes is below, you just need to check which power module you are using and use the +\/P\/- keys on the 6SN1121-0BA11-0AA1 unit to input the corresponding parameter in P-095.<\/p>\n<figure id=\"attachment_1516\" class=\"thumbnail wp-caption alignnone\" style=\"width: 551px\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-1516 size-full\" src=\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2016\/04\/Power-Module-Code.png\" alt=\"Power Module Codes\" width=\"541\" height=\"370\" srcset=\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2016\/04\/Power-Module-Code.png 541w, https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2016\/04\/Power-Module-Code-300x205.png 300w\" sizes=\"auto, (max-width: 541px) 100vw, 541px\" \/><figcaption class=\"caption wp-caption-text\">Power Module Codes<\/figcaption><\/figure>\n<p>It is also possible that you will need to re-initialize the drive to input P-095 to the correct code number. Here are the instructions to re-initialize the drive converter.<\/p>\n<p>Re-initializing the drive converter- If required, save the setting data (parameters)<br \/>\n&#8211; Remove the write protection: Set P-051 to 4H<br \/>\n&#8211; Start initialization: Set P-097 to 0H<br \/>\n&#8211; Overwite the parameters in the drive-machine data memory: Set P-052 to 1H and wait until it resets back to 0H<br \/>\n&#8211; Power on reset: Power down the unit and power it back up after the display has been dark for 2 seconds. P-095 or P-096 must be displayed.<\/p>\n<p>After re-initializing you will be able to change P-095 to the correct code and the\u00a0Simodrive F-16 Alarm fault should clear.<\/p>\n<p>On the front of the <a href=\"https:\/\/www.mroelectric.com\/siemens\/simodrive\/1\">Siemens Simodrive<\/a> monitoring and NE modules there is a series of 6 LED lights that are used to diagnose issues with the drive. We have a diagram of the LED below along with the meaning of each light so that customers can properly diagnose their <a href=\"https:\/\/www.mroelectric.com\/siemens\/1\">Siemens<\/a> Simodrives.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter\" src=\"data:image\/png;base64,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\" alt=\"\" \/><\/p>\n<p><!--more--><\/p>\n<p>1 LED, red \u2013 \u000115 V electronics power supply faulted<\/p>\n<p>2 LED, red \u2013 5 V voltage level faulted<\/p>\n<p>3 LED green \u2013 external enable signals not available<br \/>\n(terminal 63 and\/or terminal 64 missing)<br \/>\n4 LED yellow \u2013 DC link charged<\/p>\n<p>5 LED, red \u2013 line supply fault (single\u2013 or multi\u2013phase supply failure at the<br \/>\nterminals U1, V1, W1) 1)<br \/>\n\u2013 commutating reactor either not available or incorrectly selected,<br \/>\n\u2013 fault level of the line supply or transformer too low<\/p>\n<p>6 LED red \u2013 DC link overvoltage<br \/>\npossible causes: Regenerative feedback off, setting\u2013up operation,<br \/>\nline supply fault, for UE pulsed\u2013resistor not operational, line supply<br \/>\nvoltage too high, dynamic overload condition<\/p>\n<p>Effects:<br \/>\n1 red LED bright: Pulses for the complete drive group are canceled<br \/>\n2 red LED bright: Pulses for the complete drive group are canceled<br \/>\n4 yellow LED dark: xxxx<br \/>\n5 red LED bright: 1) Only the I\/R module pulses are canceled (regenerative feedback<br \/>\nno longer possible. Axes first continue to run. Ready relay drops\u2013out<br \/>\n6 red LED bright: Pulses for the complete drive group are canceled<\/p>\n<p><!--more--><\/p>\n<p>We also had a customer with a <a href=\"https:\/\/www.mroelectric.com\/product\/6SN1123-1AA00-0CA1\">6SN1123-1AA00-0CA1<\/a> <a href=\"https:\/\/www.mroelectric.com\/siemens\/simodrive\/1\">Simodrive<\/a> LT Module that they were getting a fault code 7 on. This fault code has to do with the speed controller being at it&#8217;s limit. This alarm was coming up randomly for them, and would go away temporarily if they swapped out their motor with a spare. The controller card that they were using was a <a href=\"https:\/\/www.mroelectric.com\/product\/6SN1118-0AA11-0AA1\">6SN1118-0AA11-0AA1<\/a> card, which was determined as faulty once the other components were tested. Once the card was replaced, the customer was able to get up and running.<\/p>\n<h6>For more info about Simodrive and to see what we stock, you can view our <a href=\"https:\/\/www.mroelectric.com\/siemens\/simodrive\/1\">Simodrive<\/a> Series page. To get a quote, please email <a title=\"Quote Request\" href=\"mailto:sales@mroelectric.com\">sales@mroelectric.com<\/a> or call <a href=\"tel:1-800-691-8511\">1-800-691-8511<\/a>.<\/h6>\n","protected":false},"excerpt":{"rendered":"<p>We recently had a customer install a replacement 6SN1121-0BA11-0AA1 card into a 6SN1123-1AA00-0EA1 power module. When they installed the card it came up with an F-16 alarm code on the display of it, which references an &#8220;Illegal Power Module.&#8221; Using the instructions in the manual for the start-up of a replacement Simodrive card or power [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"","_lmt_disable":"","_exactmetrics_skip_tracking":false,"_exactmetrics_sitenote_active":false,"_exactmetrics_sitenote_note":"","_exactmetrics_sitenote_category":0,"ngg_post_thumbnail":0,"footnotes":""},"categories":[235,12],"tags":[55],"class_list":["post-962","post","type-post","status-publish","format-standard","hentry","category-siemens","category-troubleshooting-and-repair","tag-simodrive"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v25.3.1 (Yoast SEO v25.3.1) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Siemens Simodrive F-16 Alarm Code Troubleshooting<\/title>\n<meta name=\"description\" content=\"Info on how to re-initialize a Siemens Simodrive to clear a Simodrive F-16 Alarm by inputting the correct power supply code.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.mroelectric.com\/blog\/simodrive-f-16-alarm-code-troubleshooting\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Simodrive F-16 Alarm Code Troubleshooting &amp; Diagnostics\" \/>\n<meta property=\"og:description\" content=\"Info on how to re-initialize a Siemens Simodrive to clear a Simodrive F-16 Alarm by inputting the correct power supply code.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.mroelectric.com\/blog\/simodrive-f-16-alarm-code-troubleshooting\/\" \/>\n<meta property=\"og:site_name\" content=\"MRO Electric Blog\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/mroelectric\/\" \/>\n<meta property=\"article:published_time\" content=\"2016-04-07T20:46:03+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2019-08-29T19:56:18+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2016\/04\/Power-Module-Code.png\" \/>\n<meta name=\"author\" content=\"Joe Kaminski\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@mroelectric\" \/>\n<meta name=\"twitter:site\" content=\"@mroelectric\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Joe Kaminski\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/simodrive-f-16-alarm-code-troubleshooting\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/simodrive-f-16-alarm-code-troubleshooting\/\"},\"author\":{\"name\":\"Joe Kaminski\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/b993515a2417163a23dfe88597c8d13a\"},\"headline\":\"Simodrive F-16 Alarm Code Troubleshooting &#038; Diagnostics\",\"datePublished\":\"2016-04-07T20:46:03+00:00\",\"dateModified\":\"2019-08-29T19:56:18+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/simodrive-f-16-alarm-code-troubleshooting\/\"},\"wordCount\":667,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#organization\"},\"image\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/simodrive-f-16-alarm-code-troubleshooting\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2016\/04\/Power-Module-Code.png\",\"keywords\":[\"Simodrive\"],\"articleSection\":[\"Siemens\",\"Troubleshooting &amp; Repair\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/www.mroelectric.com\/blog\/simodrive-f-16-alarm-code-troubleshooting\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/simodrive-f-16-alarm-code-troubleshooting\/\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/simodrive-f-16-alarm-code-troubleshooting\/\",\"name\":\"Siemens Simodrive F-16 Alarm Code Troubleshooting\",\"isPartOf\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/simodrive-f-16-alarm-code-troubleshooting\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/simodrive-f-16-alarm-code-troubleshooting\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2016\/04\/Power-Module-Code.png\",\"datePublished\":\"2016-04-07T20:46:03+00:00\",\"dateModified\":\"2019-08-29T19:56:18+00:00\",\"description\":\"Info on how to re-initialize a Siemens Simodrive to clear a Simodrive F-16 Alarm by inputting the correct power supply code.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/simodrive-f-16-alarm-code-troubleshooting\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.mroelectric.com\/blog\/simodrive-f-16-alarm-code-troubleshooting\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/simodrive-f-16-alarm-code-troubleshooting\/#primaryimage\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2016\/04\/Power-Module-Code.png\",\"contentUrl\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2016\/04\/Power-Module-Code.png\",\"width\":541,\"height\":370,\"caption\":\"Power Module Codea\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/simodrive-f-16-alarm-code-troubleshooting\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.mroelectric.com\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Simodrive F-16 Alarm Code Troubleshooting &#038; Diagnostics\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#website\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/\",\"name\":\"MRO Electric Blog\",\"description\":\"Applications of PLCs, CNCs, and more!\",\"publisher\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.mroelectric.com\/blog\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#organization\",\"name\":\"MRO Electric and Supply\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro-logo-new_large2_blue-1.png\",\"contentUrl\":\"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro-logo-new_large2_blue-1.png\",\"width\":430,\"height\":222,\"caption\":\"MRO Electric and Supply\"},\"image\":{\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/mroelectric\/\",\"https:\/\/x.com\/mroelectric\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/b993515a2417163a23dfe88597c8d13a\",\"name\":\"Joe Kaminski\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/fb7c0d641ed541ad912b27609e8079304fc356be7b5b53578b32ad3fa973f506?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/fb7c0d641ed541ad912b27609e8079304fc356be7b5b53578b32ad3fa973f506?s=96&d=mm&r=g\",\"caption\":\"Joe Kaminski\"},\"description\":\"Joe Kaminski is an industrial automation specialist at MRO Electric. He has a background in industrial engineering and supply chain management. Joe has worked in the automation industry for over 10 years providing support to some of the largest companies in the world. For more info, visit www.mroelectric.com.\",\"url\":\"https:\/\/www.mroelectric.com\/blog\/author\/jadmin\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Siemens Simodrive F-16 Alarm Code Troubleshooting","description":"Info on how to re-initialize a Siemens Simodrive to clear a Simodrive F-16 Alarm by inputting the correct power supply code.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.mroelectric.com\/blog\/simodrive-f-16-alarm-code-troubleshooting\/","og_locale":"en_US","og_type":"article","og_title":"Simodrive F-16 Alarm Code Troubleshooting & Diagnostics","og_description":"Info on how to re-initialize a Siemens Simodrive to clear a Simodrive F-16 Alarm by inputting the correct power supply code.","og_url":"https:\/\/www.mroelectric.com\/blog\/simodrive-f-16-alarm-code-troubleshooting\/","og_site_name":"MRO Electric Blog","article_publisher":"https:\/\/www.facebook.com\/mroelectric\/","article_published_time":"2016-04-07T20:46:03+00:00","article_modified_time":"2019-08-29T19:56:18+00:00","og_image":[{"url":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2016\/04\/Power-Module-Code.png","type":"","width":"","height":""}],"author":"Joe Kaminski","twitter_card":"summary_large_image","twitter_creator":"@mroelectric","twitter_site":"@mroelectric","twitter_misc":{"Written by":"Joe Kaminski","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.mroelectric.com\/blog\/simodrive-f-16-alarm-code-troubleshooting\/#article","isPartOf":{"@id":"https:\/\/www.mroelectric.com\/blog\/simodrive-f-16-alarm-code-troubleshooting\/"},"author":{"name":"Joe Kaminski","@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/b993515a2417163a23dfe88597c8d13a"},"headline":"Simodrive F-16 Alarm Code Troubleshooting &#038; Diagnostics","datePublished":"2016-04-07T20:46:03+00:00","dateModified":"2019-08-29T19:56:18+00:00","mainEntityOfPage":{"@id":"https:\/\/www.mroelectric.com\/blog\/simodrive-f-16-alarm-code-troubleshooting\/"},"wordCount":667,"commentCount":0,"publisher":{"@id":"https:\/\/www.mroelectric.com\/blog\/#organization"},"image":{"@id":"https:\/\/www.mroelectric.com\/blog\/simodrive-f-16-alarm-code-troubleshooting\/#primaryimage"},"thumbnailUrl":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2016\/04\/Power-Module-Code.png","keywords":["Simodrive"],"articleSection":["Siemens","Troubleshooting &amp; Repair"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.mroelectric.com\/blog\/simodrive-f-16-alarm-code-troubleshooting\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.mroelectric.com\/blog\/simodrive-f-16-alarm-code-troubleshooting\/","url":"https:\/\/www.mroelectric.com\/blog\/simodrive-f-16-alarm-code-troubleshooting\/","name":"Siemens Simodrive F-16 Alarm Code Troubleshooting","isPartOf":{"@id":"https:\/\/www.mroelectric.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.mroelectric.com\/blog\/simodrive-f-16-alarm-code-troubleshooting\/#primaryimage"},"image":{"@id":"https:\/\/www.mroelectric.com\/blog\/simodrive-f-16-alarm-code-troubleshooting\/#primaryimage"},"thumbnailUrl":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2016\/04\/Power-Module-Code.png","datePublished":"2016-04-07T20:46:03+00:00","dateModified":"2019-08-29T19:56:18+00:00","description":"Info on how to re-initialize a Siemens Simodrive to clear a Simodrive F-16 Alarm by inputting the correct power supply code.","breadcrumb":{"@id":"https:\/\/www.mroelectric.com\/blog\/simodrive-f-16-alarm-code-troubleshooting\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.mroelectric.com\/blog\/simodrive-f-16-alarm-code-troubleshooting\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mroelectric.com\/blog\/simodrive-f-16-alarm-code-troubleshooting\/#primaryimage","url":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2016\/04\/Power-Module-Code.png","contentUrl":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/2016\/04\/Power-Module-Code.png","width":541,"height":370,"caption":"Power Module Codea"},{"@type":"BreadcrumbList","@id":"https:\/\/www.mroelectric.com\/blog\/simodrive-f-16-alarm-code-troubleshooting\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.mroelectric.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Simodrive F-16 Alarm Code Troubleshooting &#038; Diagnostics"}]},{"@type":"WebSite","@id":"https:\/\/www.mroelectric.com\/blog\/#website","url":"https:\/\/www.mroelectric.com\/blog\/","name":"MRO Electric Blog","description":"Applications of PLCs, CNCs, and more!","publisher":{"@id":"https:\/\/www.mroelectric.com\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.mroelectric.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.mroelectric.com\/blog\/#organization","name":"MRO Electric and Supply","url":"https:\/\/www.mroelectric.com\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro-logo-new_large2_blue-1.png","contentUrl":"https:\/\/www.mroelectric.com\/blog\/wp-content\/uploads\/mro-logo-new_large2_blue-1.png","width":430,"height":222,"caption":"MRO Electric and Supply"},"image":{"@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/mroelectric\/","https:\/\/x.com\/mroelectric"]},{"@type":"Person","@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/b993515a2417163a23dfe88597c8d13a","name":"Joe Kaminski","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mroelectric.com\/blog\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/fb7c0d641ed541ad912b27609e8079304fc356be7b5b53578b32ad3fa973f506?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/fb7c0d641ed541ad912b27609e8079304fc356be7b5b53578b32ad3fa973f506?s=96&d=mm&r=g","caption":"Joe Kaminski"},"description":"Joe Kaminski is an industrial automation specialist at MRO Electric. He has a background in industrial engineering and supply chain management. Joe has worked in the automation industry for over 10 years providing support to some of the largest companies in the world. For more info, visit www.mroelectric.com.","url":"https:\/\/www.mroelectric.com\/blog\/author\/jadmin\/"}]}},"modified_by":"Brian Hughes","_links":{"self":[{"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/posts\/962","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/comments?post=962"}],"version-history":[{"count":9,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/posts\/962\/revisions"}],"predecessor-version":[{"id":4357,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/posts\/962\/revisions\/4357"}],"wp:attachment":[{"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/media?parent=962"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/categories?post=962"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.mroelectric.com\/blog\/wp-json\/wp\/v2\/tags?post=962"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}